These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 28086245)

  • 1. Use of All-polyethylene Tibial Components in Unicompartmental Knee Arthroplasty Increases the Risk of Early Failure.
    Koh IJ; Suhl KH; Kim MW; Kim MS; Choi KY; In Y
    J Knee Surg; 2017 Oct; 30(8):807-815. PubMed ID: 28086245
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Revision of Unicompartmental to Total Knee Arthroplasty: Does the Unicompartmental Implant (Metal-Backed vs All-Polyethylene) Impact the Total Knee Arthroplasty?
    Scott CEH; Powell-Bowns MFR; MacDonald DJ; Simpson PM; Wade FA
    J Arthroplasty; 2018 Jul; 33(7):2203-2209. PubMed ID: 29525342
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Metal-Backed Tibial Components Do Not Reduce Risk of Early Aseptic Loosening in Unicompartmental Knee Arthroplasty: A Systematic Review and Meta-Analysis.
    Costa GG; Lo Presti M; Grassi A; Agrò G; Cialdella S; Mosca M; Caravelli S; Zaffagnini S
    J Knee Surg; 2020 Feb; 33(2):180-189. PubMed ID: 30650439
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metal-backed or all-poly tibial components: which are better for medial unicompartmental knee arthroplasty? A propensity-score-matching retrospective study at the 5-year follow-up.
    Piovan G; De Berardinis L; Screpis D; Senarighi M; Povegliano L; Natali S; Gigante AP; Zorzi C
    J Orthop Traumatol; 2024 May; 25(1):24. PubMed ID: 38704499
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Unicompartmental Knee Arthroplasty Revision to TKA: Are Tibial Stems and Augments Associated With Improved Survivorship?
    Lewis PL; Davidson DC; Graves SE; de Steiger RN; Donnelly W; Cuthbert A
    Clin Orthop Relat Res; 2018 Apr; 476(4):854-862. PubMed ID: 29481343
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Do bone loss and reconstruction procedures differ at revision of cemented unicompartmental knee prostheses according to the use of metal-back or all-polyethylene tibial component?
    Rouanet T; Combes A; Migaud H; Pasquier G
    Orthop Traumatol Surg Res; 2013 Oct; 99(6):687-92. PubMed ID: 23810395
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Changes in Bone Density in Metal-Backed and All-Polyethylene Medial Unicompartmental Knee Arthroplasty.
    Scott CE; Wade FA; Bhattacharya R; MacDonald D; Pankaj P; Nutton RW
    J Arthroplasty; 2016 Mar; 31(3):702-9. PubMed ID: 26601632
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surgeon's experience influences UKA survivorship: a comparative study between all-poly and metal back designs.
    Zambianchi F; Digennaro V; Giorgini A; Grandi G; Fiacchi F; Mugnai R; Catani F
    Knee Surg Sports Traumatol Arthrosc; 2015 Jul; 23(7):2074-80. PubMed ID: 24682516
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Unicompartmental knee arthroplasties: does the type of tibial component selected influence implant survival?
    Montilla FJ; Payo-Ollero J; Serrano-Toledano D; Del Río-Arteaga M; Ribera J; Muela R
    Arch Orthop Trauma Surg; 2024 Jan; 144(1):347-355. PubMed ID: 37743356
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Survivorship and clinical outcome of the minimally invasive Uniglide medial fixed bearing, all-polyethylene tibia, unicompartmental knee arthroplasty at a mean follow-up of 7.3years.
    Forster-Horváth C; Artz N; Hassaballa MA; Robinson JR; Porteous AJ; Murray JR; Newman JH
    Knee; 2016 Dec; 23(6):981-986. PubMed ID: 27506988
    [TBL] [Abstract][Full Text] [Related]  

  • 11. All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register.
    Gudnason A; Hailer NP; W-Dahl A; Sundberg M; Robertsson O
    J Bone Joint Surg Am; 2014 Jun; 96(12):994-999. PubMed ID: 24951734
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metal or Modularity: Why Do Metal-Backed Tibias Have Inferior Outcomes to All-Polyethylene Tibial Components in Patients With Osteoarthritis.
    Houdek MT; Watts CD; Wyles CC; Martin JR; Trousdale RT; Taunton MJ
    J Arthroplasty; 2017 Mar; 32(3):836-842. PubMed ID: 27816367
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cemented all-polyethylene and metal-backed polyethylene tibial components used for primary total knee arthroplasty: a systematic review of the literature and meta-analysis of randomized controlled trials involving 1798 primary total knee implants.
    Voigt J; Mosier M
    J Bone Joint Surg Am; 2011 Oct; 93(19):1790-8. PubMed ID: 22005864
    [TBL] [Abstract][Full Text] [Related]  

  • 14. All-polyethylene tibial components in modern total knee arthroplasty.
    Browne JA; Gall Sims SE; Giuseffi SA; Trousdale RT
    J Am Acad Orthop Surg; 2011 Sep; 19(9):527-35. PubMed ID: 21885698
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative Survivorship of Different Tibial Designs in Primary Total Knee Arthroplasty.
    Kremers HM; Sierra RJ; Schleck CD; Berry DJ; Cabanela ME; Hanssen AD; Pagnano MW; Trousdale RT; Lewallen DG
    J Bone Joint Surg Am; 2014 Jul; 96(14):e121. PubMed ID: 25031383
    [TBL] [Abstract][Full Text] [Related]  

  • 16. All-polyethylene versus metal-backed tibial component in total knee arthroplasty.
    Longo UG; Ciuffreda M; D'Andrea V; Mannering N; Locher J; Denaro V
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3620-3636. PubMed ID: 27209191
    [TBL] [Abstract][Full Text] [Related]  

  • 17. All-Polyethylene Tibial Component in Unicompartmental Knee Arthroplasty Offers Excellent Survivorship and Clinical Outcomes at Short-Term Follow-Up: A Multicenter Retrospective Clinical Study.
    Bonanzinga T; Adravanti FM; Vitale U; Anzillotti G; Iacono F; Marcacci M
    Medicina (Kaunas); 2024 Sep; 60(9):. PubMed ID: 39336492
    [No Abstract]   [Full Text] [Related]  

  • 18. Bearing thickness of unicompartmental knee arthroplasty is a reliable predictor of tibial bone loss during revision to total knee arthroplasty.
    Lo Presti M; Costa GG; Grassi A; Agrò G; Cialdella S; Vasco C; Neri MP; Cucurnia I; Zaffagnini S
    Orthop Traumatol Surg Res; 2020 May; 106(3):429-434. PubMed ID: 32253136
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Minimum 10-year outcomes of a fixed bearing all-polyethylene unicompartmental knee arthroplasty used to treat medial osteoarthritis.
    Bruce DJ; Hassaballa M; Robinson JR; Porteous AJ; Murray JR; Newman JH
    Knee; 2020 Jun; 27(3):1018-1027. PubMed ID: 32220535
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A randomised trial of all-polyethylene and metal-backed tibial components in unicompartmental arthroplasty of the knee.
    Hutt JR; Farhadnia P; Massé V; LaVigne M; Vendittoli PA
    Bone Joint J; 2015 Jun; 97-B(6):786-92. PubMed ID: 26033058
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.