97 related articles for article (PubMed ID: 28087211)
21. [3D finite element analysis of bone stress around distally osseointegrated implant for artificial limb attachment].
Zheng L; Luo J; Wang X; Chen J; Gu Z; Zhang X
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Jun; 24(3):554-7. PubMed ID: 17713260
[TBL] [Abstract][Full Text] [Related]
22. The possibilities of uncemented glenoid component--a finite element study.
Gupta S; van der Helm FC; van Keulen F
Clin Biomech (Bristol, Avon); 2004 Mar; 19(3):292-302. PubMed ID: 15003345
[TBL] [Abstract][Full Text] [Related]
23. Uncemented, custom-made, hydroxyapatite-coated collared distal femoral endoprostheses: up to 18 years' follow-up.
Batta V; Coathup MJ; Parratt MT; Pollock RC; Aston WJ; Cannon SR; Skinner JA; Briggs TW; Blunn GW
Bone Joint J; 2014 Feb; 96-B(2):263-9. PubMed ID: 24493195
[TBL] [Abstract][Full Text] [Related]
24. Design and finite element analysis of femoral stem prosthesis using functional graded materials.
Ahirwar H; Sahu A; Gupta VK; Kumar P; Nanda HS
Comput Methods Biomech Biomed Engin; 2022 Aug; 25(11):1262-1275. PubMed ID: 34939875
[TBL] [Abstract][Full Text] [Related]
25. Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study.
Harrysson OL; Hosni YA; Nayfeh JF
BMC Musculoskelet Disord; 2007 Sep; 8():91. PubMed ID: 17854508
[TBL] [Abstract][Full Text] [Related]
26. Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years.
Bidar R; Kouyoumdjian P; Munini E; Asencio G
Orthop Traumatol Surg Res; 2009 Dec; 95(8):579-87. PubMed ID: 19926546
[TBL] [Abstract][Full Text] [Related]
27. [Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].
Landor I; Vavrík P; Jahoda D; Pokorný D; Ballay R; Sosna A
Acta Chir Orthop Traumatol Cech; 2009 Jun; 76(3):172-8. PubMed ID: 19595277
[TBL] [Abstract][Full Text] [Related]
28. Glenoid implant orientation and cement failure in total shoulder arthroplasty: a finite element analysis.
Yongpravat C; Kim HM; Gardner TR; Bigliani LU; Levine WN; Ahmad CS
J Shoulder Elbow Surg; 2013 Jul; 22(7):940-7. PubMed ID: 23312817
[TBL] [Abstract][Full Text] [Related]
29. All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes.
Tang F; Zhou Y; Zhang W; Min L; Shi R; Luo Y; Duan H; Tu C
J Orthop Surg Res; 2017 Apr; 12(1):57. PubMed ID: 28376828
[TBL] [Abstract][Full Text] [Related]
30. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
Merıç G; Erkmen E; Kurt A; Eser A; özden AU
Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
[TBL] [Abstract][Full Text] [Related]
31. Optimization of custom cementless stem using finite element analysis and elastic modulus distribution for reducing stress-shielding effect.
Saravana Kumar G; George SP
Proc Inst Mech Eng H; 2017 Feb; 231(2):149-159. PubMed ID: 28056711
[TBL] [Abstract][Full Text] [Related]
32. Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty.
Chen SH; Chiang MC; Hung CH; Lin SC; Chang HW
Knee; 2014 Jan; 21(1):224-31. PubMed ID: 23582376
[TBL] [Abstract][Full Text] [Related]
33. Are Complications Associated With the Repiphysis(®) Expandable Distal Femoral Prosthesis Acceptable for Its Continued Use?
Staals EL; Colangeli M; Ali N; Casanova JM; Donati DM; Manfrini M
Clin Orthop Relat Res; 2015 Sep; 473(9):3003-13. PubMed ID: 25995179
[TBL] [Abstract][Full Text] [Related]
34. FEA of Peri-Implant Stresses in Fixed Partial Denture Prostheses with Cantilevers.
Alencar SM; Nogueira LB; Leal de Moura W; Rubo JH; Saymo de Oliveira Silva T; Martins GA; Moura CD
J Prosthodont; 2017 Feb; 26(2):150-155. PubMed ID: 26588042
[TBL] [Abstract][Full Text] [Related]
35. The effect of primary stability on load transfer and bone remodelling within the uncemented resurfaced femur.
Pal B; Gupta S
Proc Inst Mech Eng H; 2011 Jun; 225(6):549-61. PubMed ID: 22034739
[TBL] [Abstract][Full Text] [Related]
36. Minimising aseptic loosening in extreme bone resections: custom-made tumour endoprostheses with short medullary stems and extra-cortical plates.
Stevenson JD; Wigley C; Burton H; Ghezelayagh S; Morris G; Evans S; Parry M; Jeys L
Bone Joint J; 2017 Dec; 99-B(12):1689-1695. PubMed ID: 29212694
[TBL] [Abstract][Full Text] [Related]
37. Design of a biomimetic polymer-composite hip prosthesis.
Bougherara H; Bureau M; Campbell M; Vadean A; Yahia L
J Biomed Mater Res A; 2007 Jul; 82(1):27-40. PubMed ID: 17265439
[TBL] [Abstract][Full Text] [Related]
38. Cementless implant composition and femoral stress. A finite element analysis.
Namba RS; Keyak JH; Kim AS; Vu LP; Skinner HB
Clin Orthop Relat Res; 1998 Feb; (347):261-7. PubMed ID: 9520899
[TBL] [Abstract][Full Text] [Related]
39. Influence of the distal femoral resection angle on the principal stresses in ceramic total knee components.
Kluess D; Bergschmidt P; Mueller I; Mittelmeier W; Bader R
Knee; 2012 Dec; 19(6):846-50. PubMed ID: 22542212
[TBL] [Abstract][Full Text] [Related]
40. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
Kovanda M; Havlícek V; Hudec J
Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]