170 related articles for article (PubMed ID: 28088392)
1. Benefits of Oxygen Saturation Targeting Trials: Oximeter Calibration Software Revision and Infant Saturations.
Whyte RK; Nelson H; Roberts RS; Schmidt B
J Pediatr; 2017 Mar; 182():382-384. PubMed ID: 28088392
[TBL] [Abstract][Full Text] [Related]
2. Pulse Oximeter Saturation Targeting and Oximeter Changes in the Benefits of Oxygen Saturation Targeting (BOOST)-II Australia and BOOST-II UK Oxygen Trials.
Stenson BJ; Donoghoe M; Brocklehurst P; Davis PG; Juszczak E; Marschner IC; Simes J; Tarnow-Mordi WO
J Pediatr; 2019 Jan; 204():301-304.e2. PubMed ID: 30314661
[TBL] [Abstract][Full Text] [Related]
3. Algorithms that eliminate the effects of calibration artefact and trial-imposed offsets of Masimo oximeter in BOOST-NZ trial.
Zahari M; Lee DS; Darlow BA
J Clin Monit Comput; 2016 Oct; 30(5):669-78. PubMed ID: 26282827
[TBL] [Abstract][Full Text] [Related]
4. Oxygen targeting in preterm infants using the Masimo SET Radical pulse oximeter.
Johnston ED; Boyle B; Juszczak E; King A; Brocklehurst P; Stenson BJ
Arch Dis Child Fetal Neonatal Ed; 2011 Nov; 96(6):F429-33. PubMed ID: 21378398
[TBL] [Abstract][Full Text] [Related]
5. Impact of study oximeter masking algorithm on titration of oxygen therapy in the Canadian oxygen trial.
Schmidt B; Roberts RS; Whyte RK; Asztalos EV; Poets C; Rabi Y; Solimano A; Nelson H;
J Pediatr; 2014 Oct; 165(4):666-71.e2. PubMed ID: 24973289
[TBL] [Abstract][Full Text] [Related]
6. Does the estimation of light attenuation in tissue increase the accuracy of reflectance pulse oximetry at low oxygen saturations in vivo?
Kisch-Wedel H; Bernreuter P; Kemming G; Albert M; Zwissler B
IEEE Trans Biomed Eng; 2009 Sep; 56(9):2271-9. PubMed ID: 19692303
[TBL] [Abstract][Full Text] [Related]
7. Calibration of a reflectance pulse oximeter in fetal lambs for arterial oxygen saturations below 70%.
Carter AM; Stiller R; König V; Jørgensen JS; Svendsen P; Huch R
J Soc Gynecol Investig; 1998; 5(5):255-9. PubMed ID: 9773401
[TBL] [Abstract][Full Text] [Related]
8. Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients.
Harris BU; Char DS; Feinstein JA; Verma A; Shiboski SC; Ramamoorthy C
Pediatr Crit Care Med; 2016 Apr; 17(4):315-20. PubMed ID: 26914626
[TBL] [Abstract][Full Text] [Related]
9. Reliability of a pulse oximeter in the detection of hyperoxemia.
Poets CF; Wilken M; Seidenberg J; Southall DP; von der Hardt H
J Pediatr; 1993 Jan; 122(1):87-90. PubMed ID: 8419620
[TBL] [Abstract][Full Text] [Related]
10. Pulse oximetry.
Wahr JA; Tremper KK; Diab M
Respir Care Clin N Am; 1995 Sep; 1(1):77-105. PubMed ID: 9390852
[TBL] [Abstract][Full Text] [Related]
11. Absolute and trend accuracy of a new regional oximeter in healthy volunteers during controlled hypoxia.
Redford D; Paidy S; Kashif F
Anesth Analg; 2014 Dec; 119(6):1315-9. PubMed ID: 25405692
[TBL] [Abstract][Full Text] [Related]
12. Pulse Oximetry with Two Infrared Wavelengths without Calibration in Extracted Arterial Blood.
Yossef Hay O; Cohen M; Nitzan I; Kasirer Y; Shahroor-Karni S; Yitzhaky Y; Engelberg S; Nitzan M
Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30326552
[TBL] [Abstract][Full Text] [Related]
13. The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia.
Foglia EE; Whyte RK; Chaudhary A; Mott A; Chen J; Propert KJ; Schmidt B
J Pediatr; 2017 Mar; 182():375-377.e2. PubMed ID: 27939107
[TBL] [Abstract][Full Text] [Related]
14. Oxygen transport and the use of pulse oximetry.
Casey G
Nurs Stand; 2001 Aug 8-14; 15(47):46-53; quiz 54-5. PubMed ID: 12214386
[TBL] [Abstract][Full Text] [Related]
15. Pulse oximeter to detect peripheral oxygen saturation in underwater rebreather ECCR diver: a preliminary study.
Di Pumpo F; Ruffino G; Malacarne P
Undersea Hyperb Med; 2019; 46(1):1-6. PubMed ID: 31154680
[TBL] [Abstract][Full Text] [Related]
16. Ultra-low-cost clinical pulse oximetry.
Petersen CL; Gan H; MacInnis MJ; Dumont GA; Ansermino JM
Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():2874-7. PubMed ID: 24110327
[TBL] [Abstract][Full Text] [Related]
17. Effects of Targeting Higher or Lower Oxygen Saturations in Centers with More Versus Less Separation between Median Saturations.
Schmidt B; Whyte RK; Shah PS; Abbasi S; Bairam A; Harrold J; Roberts RS;
J Pediatr; 2016 Nov; 178():288-291.e2. PubMed ID: 27597731
[TBL] [Abstract][Full Text] [Related]
18. Pulse oximetry in very low birth weight infants.
Polin RA; Bateman DA; Sahni R
Clin Perinatol; 2014 Dec; 41(4):1017-32. PubMed ID: 25459788
[TBL] [Abstract][Full Text] [Related]
19. Misalignment of disposable pulse oximeter probes results in false saturation readings that influence anesthetic management.
Guan Z; Baker K; Sandberg WS
Anesth Analg; 2009 Nov; 109(5):1530-3. PubMed ID: 19843792
[TBL] [Abstract][Full Text] [Related]
20. Pulse oximetry theory and calibration for low saturations.
Zonios G; Shankar U; Iyer VK
IEEE Trans Biomed Eng; 2004 May; 51(5):818-22. PubMed ID: 15132508
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]