These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
417 related articles for article (PubMed ID: 28091768)
41. Detecting cause of dislocation after total hip arthroplasty by patient-specific four-dimensional motion analysis. Miki H; Sugano N; Yonenobu K; Tsuda K; Hattori M; Suzuki N Clin Biomech (Bristol); 2013 Feb; 28(2):182-6. PubMed ID: 23219052 [TBL] [Abstract][Full Text] [Related]
42. The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies. Romagnoli M; Grassi A; Costa GG; Lazaro LE; Lo Presti M; Zaffagnini S Int Orthop; 2019 May; 43(5):1071-1082. PubMed ID: 30032356 [TBL] [Abstract][Full Text] [Related]
43. Dual-Mobility Constructs in Revision Total Hip Arthroplasties. Abdel MP J Arthroplasty; 2018 May; 33(5):1328-1330. PubMed ID: 29500088 [TBL] [Abstract][Full Text] [Related]
44. Primary total hip arthroplasty revision due to dislocation: prospective French multicenter study. Girard J; Kern G; Migaud H; Delaunay C; Ramdane N; Hamadouche M; Orthop Traumatol Surg Res; 2013 Sep; 99(5):549-53. PubMed ID: 23890966 [TBL] [Abstract][Full Text] [Related]
45. A Meta-Analysis of the Incidence and Temporal Trends of Postoperative Dislocation in Revision Total Hip Arthroplasty Utilizing Constrained Acetabular Components or Dual Mobility Implants. Donovan RL; Johnson H; Fernando S; Foxall-Smith M; Whitehouse MR; Blom AW; Kunutsor SK J Arthroplasty; 2023 May; 38(5):957-969.e1. PubMed ID: 36481281 [TBL] [Abstract][Full Text] [Related]
46. Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Adam P; Philippe R; Ehlinger M; Roche O; Bonnomet F; Molé D; Fessy MH; Orthop Traumatol Surg Res; 2012 May; 98(3):296-300. PubMed ID: 22463868 [TBL] [Abstract][Full Text] [Related]
47. Is dual mobility associated with an increased risk of revision for infection? Matched cohort of 231 cases of dual-mobility cups and 231 fixed cups. Prudhon JL; Desmarchelier R; Hamadouche M; Delaunay C; Verdier R Hip Int; 2018 Mar; 28(2):200-204. PubMed ID: 29218688 [TBL] [Abstract][Full Text] [Related]
48. Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series. Hwang JH; Kim SM; Oh KJ; Kim Y Int Orthop; 2018 Apr; 42(4):761-767. PubMed ID: 28986663 [TBL] [Abstract][Full Text] [Related]
49. The use of a constrained acetabular component for recurrent dislocation. Shapiro GS; Weiland DE; Markel DC; Padgett DE; Sculco TP; Pellicci PM J Arthroplasty; 2003 Apr; 18(3):250-8. PubMed ID: 12728414 [TBL] [Abstract][Full Text] [Related]
50. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors. Hernigou P; Roussignol X; Delambre J; Poignard A; Flouzat-Lachaniette CH Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482 [TBL] [Abstract][Full Text] [Related]
51. Dual mobility cups associated with proximal femoral replacement in nontumoral indications: Results and complications. Canetti R; Malatray M; Pibarot V; Wegrzyn J Orthop Traumatol Surg Res; 2022 Apr; 108(2):103029. PubMed ID: 34343696 [TBL] [Abstract][Full Text] [Related]
52. Fully constrained acetabular liner vs. dual mobility hip joint in the surgical treatment of metastatic bone disease of the hip: study protocol for a randomized, open-label, two-arm, non-inferiority trial evaluating the post-operative hip dislocation rate. Iljazi A; Sørensen MS; Weber KS; Villadsen A; Eriksson F; Petersen MM Trials; 2023 Mar; 24(1):204. PubMed ID: 36934286 [TBL] [Abstract][Full Text] [Related]
53. Dual-mobility total hip arthroplasty in patients younger than 55 years old: a systematic review. Zampogna B; Papalia GF; Ferrini A; Torre G; Vorini F; Diaz Balzani LA; Farsetti P; Papalia R Arch Orthop Trauma Surg; 2023 Nov; 143(11):6821-6828. PubMed ID: 37062001 [TBL] [Abstract][Full Text] [Related]
54. Total hip arthroplasty using a cementless dual-mobility cup provides increased stability and favorable gait parameters at five years follow-up. Acker A; Fischer JF; Aminian K; Lécureux E; Jolles BM Orthop Traumatol Surg Res; 2017 Feb; 103(1):21-25. PubMed ID: 27890581 [TBL] [Abstract][Full Text] [Related]
55. Can cemented dual-mobility cups be used without a reinforcement device in cases of mild acetabular bone stock alteration in total hip arthroplasty? Haen TX; Lonjon G; Vandenbussche E Orthop Traumatol Surg Res; 2015 Dec; 101(8):923-7. PubMed ID: 26542070 [TBL] [Abstract][Full Text] [Related]
56. Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component. Fehring KA; Berry DJ Clin Orthop Relat Res; 2016 Apr; 474(4):1072-6. PubMed ID: 26088765 [TBL] [Abstract][Full Text] [Related]
57. [Dislocated dual mobility liner after hip dislocation]. Graversen AE; Varnum C Ugeskr Laeger; 2020 Sep; 182(37):. PubMed ID: 33000722 [TBL] [Abstract][Full Text] [Related]
58. LUMiC Bus MP; Szafranski A; Sellevold S; Goryn T; Jutte PC; Bramer JA; Fiocco M; Streitbürger A; Kotrych D; van de Sande MA; Dijkstra PD Clin Orthop Relat Res; 2017 Mar; 475(3):686-695. PubMed ID: 27020434 [TBL] [Abstract][Full Text] [Related]
59. Early experience with dual mobility acetabular systems featuring highly cross-linked polyethylene liners for primary hip arthroplasty in patients under fifty five years of age: an international multi-centre preliminary study. Epinette JA; Harwin SF; Rowan FE; Tracol P; Mont MA; Chughtai M; Westrich GH Int Orthop; 2017 Mar; 41(3):543-550. PubMed ID: 28013332 [TBL] [Abstract][Full Text] [Related]
60. Revision for recurrent instability: what are the predictors of failure? Carter AH; Sheehan EC; Mortazavi SM; Purtill JJ; Sharkey PF; Parvizi J J Arthroplasty; 2011 Sep; 26(6 Suppl):46-52. PubMed ID: 21550768 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]