79 related articles for article (PubMed ID: 28093609)
1. Periprosthetic fracture around a stable femoral stem treated with locking plate osteosynthesis: distal femoral locking plate alone versus with cerclage cable.
Shin YS; Han SB
Eur J Orthop Surg Traumatol; 2017 Jul; 27(5):623-630. PubMed ID: 28093609
[TBL] [Abstract][Full Text] [Related]
2. Comparing the Biomechanical Stability of Cerclage Cable with Plate Insert Versus Locking Screw in Periprosthetic Humeral Fracture.
Lee YJ; Lim JR; Choi JH; Yoon TH; Choi YR; Chun YM
J Bone Joint Surg Am; 2024 May; 106(9):817-822. PubMed ID: 38381844
[TBL] [Abstract][Full Text] [Related]
3. Analysis of risk factors for revision in distal femoral fractures treated with lateral locking plate: a retrospective study in Chinese patients.
Hou G; Zhou F; Tian Y; Ji H; Zhang Z; Guo Y; Lv Y; Yang Z; Zhang Y
J Orthop Surg Res; 2020 Aug; 15(1):318. PubMed ID: 32787946
[TBL] [Abstract][Full Text] [Related]
4. Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring.
Oh SH; Suh YS; Eghan-Acquah E; Yurevich KM; Won SH; Baek MJ; Lee SJ; Choi SW
J Int Med Res; 2024 Mar; 52(3):3000605241240946. PubMed ID: 38534086
[TBL] [Abstract][Full Text] [Related]
5. Long stem revision versus short stem revision with plate osteosynthesis for Vancouver type B2 periprosthetic femoral fracture: a comparative study of eighty five cases.
Chen JJ; Hung SH; Liou JY; Chang WC; Hsu KH; Su YP; Chiu FY; Cheng MF
Int Orthop; 2024 Apr; ():. PubMed ID: 38652245
[TBL] [Abstract][Full Text] [Related]
6. Distal femoral replacement for the treatment of periprosthetic distal femoral fractures around a total knee arthroplasty: a meta-analysis.
Wood MJ; Al-Jabri T; Stelzhammer T; Brivio A; Donaldson J; Skinner JA; Barrett D
Orthop Rev (Pavia); 2024; 16():94574. PubMed ID: 38666188
[TBL] [Abstract][Full Text] [Related]
7. Minimally invasive surgery of femoral periprosthetic fractures increases the rate of consolidation and decreases time to bone healing without a higher rate of complications.
Le Baron M; Battut T; Bégué T; Ehlinger M; Flecher X;
Orthop Traumatol Surg Res; 2024 Mar; ():103866. PubMed ID: 38460917
[TBL] [Abstract][Full Text] [Related]
8. Surgical outcomes of non-periprosthetic distal femur fragility fractures treated with a locking plate.
Liu J; Hein D; Huffman C; Rao BM; Cooper J; Ebraheim NA
Ann Jt; 2022; 7():32. PubMed ID: 38529163
[TBL] [Abstract][Full Text] [Related]
9. Treatment of Periprosthetic Hip Fractures Vancouver B1 and C: The Significance of Bicortical Fixation. A Bicentric Study Comparing Two Osteosynthesis Systems.
Tigani D; Ferranti Calderoni E; Melucci G; Pizzo A; Ghilotti M; Castelli A; Pasta G; Grassi F; Jannelli E
Orthop Rev (Pavia); 2024; 16():117203. PubMed ID: 38751453
[TBL] [Abstract][Full Text] [Related]
10. Use of locking plates for fixation of the greater trochanter in patients with hip replacement.
Tetreault AK; McGrory BJ
Arthroplast Today; 2016 Dec; 2(4):187-192. PubMed ID: 28326426
[TBL] [Abstract][Full Text] [Related]
11. Internal Fixation of an Intertrochanteric Fracture after Resurfacing Arthroplasty: A Case Report.
Koulischer S; Devos S; Verstraeten PB; Delahaut O; Muhadri A
J Orthop Case Rep; 2020; 9(6):65-69. PubMed ID: 32548032
[TBL] [Abstract][Full Text] [Related]
12. Application of hip prosthesis combined with anatomical locking plate of distal fibula in the treatment of geriatric intertrochanteric fractures.
Zhang C; Chang J; Wu Y; Ma G
Asian J Surg; 2024 Apr; 47(4):1863-1864. PubMed ID: 38182504
[No Abstract] [Full Text] [Related]
13. Locking Attachment Plate for the Surgical Treatment of Periprosthetic and Periimplant Fractures: Long-Term Follow-Up.
Raganato R; Mills S; Crespo-Lastras P; Gonzalez-Ruíz N; Rubio-Saez I; Pallares-Sanmartin J; Martinez-Díez JM; Ibarzabal-Gil A; Rubio-Suarez JC; Rodriguez-Merchan EC
Arch Bone Jt Surg; 2024; 12(4):256-263. PubMed ID: 38716182
[TBL] [Abstract][Full Text] [Related]
14. Adequate bone healing after supplementary fixation of periprosthetic total knee arthroplasty fractures using Luque cerclage wiring: a retrospective case series.
Mahmoud AN; Echeverry-Martinez MF; Horwitz DS
Eur J Orthop Surg Traumatol; 2024 Jan; 34(1):389-395. PubMed ID: 37540245
[TBL] [Abstract][Full Text] [Related]
15. The race for the classification of proximal periprosthetic femoral fractures : Vancouver vs Unified Classification System (UCS) - a systematic review.
Schopper C; Luger M; Hipmair G; Schauer B; Gotterbarm T; Klasan A
BMC Musculoskelet Disord; 2022 Mar; 23(1):280. PubMed ID: 35321671
[TBL] [Abstract][Full Text] [Related]
16. Combined Surgical and Medical Treatment for Vancouver B1 and C Periprosthetic Femoral Fractures: A Proposal of a Therapeutic Algorithm While Retaining the Original Stable Stem.
Mondanelli N; Troiano E; Facchini A; Cesari M; Colasanti GB; Bottai V; Muratori F; Caffarelli C; Gonnelli S; Giannotti S
Geriatr Orthop Surg Rehabil; 2021; 12():21514593211067072. PubMed ID: 34992896
[TBL] [Abstract][Full Text] [Related]
17. High Failure Rates of Locking Compression Plate Osteosynthesis with Transverse Fracture around a Well-Fixed Stem Tip for Periprosthetic Femoral Fracture.
Min BW; Lee KJ; Cho CH; Lee IG; Kim BS
J Clin Med; 2020 Nov; 9(11):. PubMed ID: 33266369
[TBL] [Abstract][Full Text] [Related]
18. Challenges of Plate Fixation for Vancouver Type-C fractures after a Well-fixed Hip Arthroplasty Femoral Stem.
Ganji R
Arch Bone Jt Surg; 2019 Nov; 7(6):571-572. PubMed ID: 31970264
[No Abstract] [Full Text] [Related]
19. Extended trochanteric osteotomy (ETO) fixation for femoral stem revision in periprosthetic fractures: Dall-Miles plate versus cables.
Sheridan GA; Galbraith A; Kearns SR; Curtin W; Murphy CG
Eur J Orthop Surg Traumatol; 2018 Apr; 28(3):471-476. PubMed ID: 29058079
[TBL] [Abstract][Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
[Next] [New Search]