1. Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome.
Franchineau G; Bréchot N; Lebreton G; Hekimian G; Nieszkowska A; Trouillet JL; Leprince P; Chastre J; Luyt CE; Combes A; Schmidt M
Am J Respir Crit Care Med; 2017 Aug; 196(4):447-457. PubMed ID: 28103448
[TBL] [Abstract][Full Text] [Related]
2. Assessment of electrical impedance tomography to set optimal positive end-expiratory pressure for veno-venous ECMO-treated severe ARDS patients.
Puel F; Crognier L; Soulé C; Vardon-Bounes F; Ruiz S; Seguin T; Fourcade O; Minville V; Conil JM; Georges B
J Crit Care; 2020 Dec; 60():38-44. PubMed ID: 32736198
[TBL] [Abstract][Full Text] [Related]
3. Dynamic Relative Regional Lung Strain Estimated by Electrical Impedance Tomography in an Experimental Model of ARDS.
Gogniat E; Madorno M; Rodriguez PO; Dianti J; Otero PE; Krukewitt L; Böhm SH; Roman ES; Tusman G
Respir Care; 2022 Aug; 67(8):906-913. PubMed ID: 35610029
[TBL] [Abstract][Full Text] [Related]
4. Electrical impedance tomography: A compass for the safe route to optimal PEEP.
Sella N; Pettenuzzo T; Zarantonello F; Andreatta G; De Cassai A; Schiavolin C; Simoni C; Pasin L; Boscolo A; Navalesi P
Respir Med; 2021 Oct; 187():106555. PubMed ID: 34352563
[TBL] [Abstract][Full Text] [Related]
5. Electrical impedance tomography monitoring in acute respiratory distress syndrome patients with mechanical ventilation during prolonged positive end-expiratory pressure adjustments.
Hsu CF; Cheng JS; Lin WC; Ko YF; Cheng KS; Lin SH; Chen CW
J Formos Med Assoc; 2016 Mar; 115(3):195-202. PubMed ID: 25843526
[TBL] [Abstract][Full Text] [Related]
6. Detection of 'best' positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial.
Blankman P; Hasan D; Erik G; Gommers D
Crit Care; 2014 May; 18(3):R95. PubMed ID: 24887391
[TBL] [Abstract][Full Text] [Related]
7. Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography.
Meier T; Luepschen H; Karsten J; Leibecke T; Grossherr M; Gehring H; Leonhardt S
Intensive Care Med; 2008 Mar; 34(3):543-50. PubMed ID: 17653529
[TBL] [Abstract][Full Text] [Related]
8. Assessment of Electrical Impedance Tomography to Set Optimal Positive End-Expiratory Pressure for Venoarterial Extracorporeal Membrane Oxygenation-Treated Patients.
Soulé C; Crognier L; Puel F; Ruiz S; Seguin T; Fourcade O; Georges B; Conil JM; Minville V; Vardon-Bounes F
Crit Care Med; 2021 Jun; 49(6):923-933. PubMed ID: 33595959
[TBL] [Abstract][Full Text] [Related]
9. Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study.
Suarez-Sipmann F; Böhm SH; Tusman G; Pesch T; Thamm O; Reissmann H; Reske A; Magnusson A; Hedenstierna G
Crit Care Med; 2007 Jan; 35(1):214-21. PubMed ID: 17110872
[TBL] [Abstract][Full Text] [Related]
10. Clinical implementation of electric impedance tomography in the treatment of ARDS: a single centre experience.
Heines SJH; Strauch U; van de Poll MCG; Roekaerts PMHJ; Bergmans DCJJ
J Clin Monit Comput; 2019 Apr; 33(2):291-300. PubMed ID: 29845479
[TBL] [Abstract][Full Text] [Related]
11. Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients.
Bikker IG; Leonhardt S; Reis Miranda D; Bakker J; Gommers D
Crit Care; 2010; 14(3):R100. PubMed ID: 20509966
[TBL] [Abstract][Full Text] [Related]
12. Physiological Effects of the Open Lung Approach in Patients with Early, Mild, Diffuse Acute Respiratory Distress Syndrome: An Electrical Impedance Tomography Study.
Cinnella G; Grasso S; Raimondo P; D'Antini D; Mirabella L; Rauseo M; Dambrosio M
Anesthesiology; 2015 Nov; 123(5):1113-21. PubMed ID: 26397017
[TBL] [Abstract][Full Text] [Related]
13. Detection of optimal PEEP for equal distribution of tidal volume by volumetric capnography and electrical impedance tomography during decreasing levels of PEEP in post cardiac-surgery patients.
Blankman P; Shono A; Hermans BJ; Wesselius T; Hasan D; Gommers D
Br J Anaesth; 2016 Jun; 116(6):862-9. PubMed ID: 27199318
[TBL] [Abstract][Full Text] [Related]
14. Lung recruitment maneuvers in acute respiratory distress syndrome and facilitating resolution.
Valente Barbas CS
Crit Care Med; 2003 Apr; 31(4 Suppl):S265-71. PubMed ID: 12682451
[TBL] [Abstract][Full Text] [Related]
15. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.
Spadaro S; Mauri T; Böhm SH; Scaramuzzo G; Turrini C; Waldmann AD; Ragazzi R; Pesenti A; Volta CA
Crit Care; 2018 Jan; 22(1):26. PubMed ID: 29386048
[TBL] [Abstract][Full Text] [Related]
16. Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography.
Grivans C; Lundin S; Stenqvist O; Lindgren S
Acta Anaesthesiol Scand; 2011 Oct; 55(9):1068-77. PubMed ID: 22092203
[TBL] [Abstract][Full Text] [Related]
17. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography.
Mauri T; Eronia N; Turrini C; Battistini M; Grasselli G; Rona R; Volta CA; Bellani G; Pesenti A
Intensive Care Med; 2016 Oct; 42(10):1576-1587. PubMed ID: 27518321
[TBL] [Abstract][Full Text] [Related]
18. Positive End-expiratory Pressure Titration after Alveolar Recruitment Directed by Electrical Impedance Tomography.
Long Y; Liu DW; He HW; Zhao ZQ
Chin Med J (Engl); 2015 Jun; 128(11):1421-7. PubMed ID: 26021494
[TBL] [Abstract][Full Text] [Related]
19. Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography.
Lowhagen K; Lundin S; Stenqvist O
Minerva Anestesiol; 2010 Dec; 76(12):1024-35. PubMed ID: 21178912
[TBL] [Abstract][Full Text] [Related]
20. Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial.
Bikker IG; Preis C; Egal M; Bakker J; Gommers D
Crit Care; 2011 Aug; 15(4):R193. PubMed ID: 21834953
[TBL] [Abstract][Full Text] [Related]