BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1795 related articles for article (PubMed ID: 28103448)

  • 1. Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome.
    Franchineau G; Bréchot N; Lebreton G; Hekimian G; Nieszkowska A; Trouillet JL; Leprince P; Chastre J; Luyt CE; Combes A; Schmidt M
    Am J Respir Crit Care Med; 2017 Aug; 196(4):447-457. PubMed ID: 28103448
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of electrical impedance tomography to set optimal positive end-expiratory pressure for veno-venous ECMO-treated severe ARDS patients.
    Puel F; Crognier L; Soulé C; Vardon-Bounes F; Ruiz S; Seguin T; Fourcade O; Minville V; Conil JM; Georges B
    J Crit Care; 2020 Dec; 60():38-44. PubMed ID: 32736198
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dynamic Relative Regional Lung Strain Estimated by Electrical Impedance Tomography in an Experimental Model of ARDS.
    Gogniat E; Madorno M; Rodriguez PO; Dianti J; Otero PE; Krukewitt L; Böhm SH; Roman ES; Tusman G
    Respir Care; 2022 Aug; 67(8):906-913. PubMed ID: 35610029
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrical impedance tomography: A compass for the safe route to optimal PEEP.
    Sella N; Pettenuzzo T; Zarantonello F; Andreatta G; De Cassai A; Schiavolin C; Simoni C; Pasin L; Boscolo A; Navalesi P
    Respir Med; 2021 Oct; 187():106555. PubMed ID: 34352563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrical impedance tomography monitoring in acute respiratory distress syndrome patients with mechanical ventilation during prolonged positive end-expiratory pressure adjustments.
    Hsu CF; Cheng JS; Lin WC; Ko YF; Cheng KS; Lin SH; Chen CW
    J Formos Med Assoc; 2016 Mar; 115(3):195-202. PubMed ID: 25843526
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of 'best' positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial.
    Blankman P; Hasan D; Erik G; Gommers D
    Crit Care; 2014 May; 18(3):R95. PubMed ID: 24887391
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography.
    Meier T; Luepschen H; Karsten J; Leibecke T; Grossherr M; Gehring H; Leonhardt S
    Intensive Care Med; 2008 Mar; 34(3):543-50. PubMed ID: 17653529
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of Electrical Impedance Tomography to Set Optimal Positive End-Expiratory Pressure for Venoarterial Extracorporeal Membrane Oxygenation-Treated Patients.
    Soulé C; Crognier L; Puel F; Ruiz S; Seguin T; Fourcade O; Georges B; Conil JM; Minville V; Vardon-Bounes F
    Crit Care Med; 2021 Jun; 49(6):923-933. PubMed ID: 33595959
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study.
    Suarez-Sipmann F; Böhm SH; Tusman G; Pesch T; Thamm O; Reissmann H; Reske A; Magnusson A; Hedenstierna G
    Crit Care Med; 2007 Jan; 35(1):214-21. PubMed ID: 17110872
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical implementation of electric impedance tomography in the treatment of ARDS: a single centre experience.
    Heines SJH; Strauch U; van de Poll MCG; Roekaerts PMHJ; Bergmans DCJJ
    J Clin Monit Comput; 2019 Apr; 33(2):291-300. PubMed ID: 29845479
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients.
    Bikker IG; Leonhardt S; Reis Miranda D; Bakker J; Gommers D
    Crit Care; 2010; 14(3):R100. PubMed ID: 20509966
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Physiological Effects of the Open Lung Approach in Patients with Early, Mild, Diffuse Acute Respiratory Distress Syndrome: An Electrical Impedance Tomography Study.
    Cinnella G; Grasso S; Raimondo P; D'Antini D; Mirabella L; Rauseo M; Dambrosio M
    Anesthesiology; 2015 Nov; 123(5):1113-21. PubMed ID: 26397017
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detection of optimal PEEP for equal distribution of tidal volume by volumetric capnography and electrical impedance tomography during decreasing levels of PEEP in post cardiac-surgery patients.
    Blankman P; Shono A; Hermans BJ; Wesselius T; Hasan D; Gommers D
    Br J Anaesth; 2016 Jun; 116(6):862-9. PubMed ID: 27199318
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lung recruitment maneuvers in acute respiratory distress syndrome and facilitating resolution.
    Valente Barbas CS
    Crit Care Med; 2003 Apr; 31(4 Suppl):S265-71. PubMed ID: 12682451
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.
    Spadaro S; Mauri T; Böhm SH; Scaramuzzo G; Turrini C; Waldmann AD; Ragazzi R; Pesenti A; Volta CA
    Crit Care; 2018 Jan; 22(1):26. PubMed ID: 29386048
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography.
    Grivans C; Lundin S; Stenqvist O; Lindgren S
    Acta Anaesthesiol Scand; 2011 Oct; 55(9):1068-77. PubMed ID: 22092203
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography.
    Mauri T; Eronia N; Turrini C; Battistini M; Grasselli G; Rona R; Volta CA; Bellani G; Pesenti A
    Intensive Care Med; 2016 Oct; 42(10):1576-1587. PubMed ID: 27518321
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Positive End-expiratory Pressure Titration after Alveolar Recruitment Directed by Electrical Impedance Tomography.
    Long Y; Liu DW; He HW; Zhao ZQ
    Chin Med J (Engl); 2015 Jun; 128(11):1421-7. PubMed ID: 26021494
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography.
    Lowhagen K; Lundin S; Stenqvist O
    Minerva Anestesiol; 2010 Dec; 76(12):1024-35. PubMed ID: 21178912
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial.
    Bikker IG; Preis C; Egal M; Bakker J; Gommers D
    Crit Care; 2011 Aug; 15(4):R193. PubMed ID: 21834953
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 90.