650 related articles for article (PubMed ID: 28103852)
1. Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study.
Liu W; Yang L; Kong X; An L; Hong G; Guo Z; Zang L
BMC Musculoskelet Disord; 2017 Jan; 18(1):26. PubMed ID: 28103852
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures.
Su H; Zhong S; Ma T; Wu W; Lu Y; Wang D
BMC Musculoskelet Disord; 2023 Jan; 24(1):39. PubMed ID: 36650508
[TBL] [Abstract][Full Text] [Related]
3. Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis.
Blažević D; Kodvanj J; Adamović P; Vidović D; Trobonjača Z; Sabalić S
J Orthop Surg Res; 2022 Jan; 17(1):16. PubMed ID: 35016716
[TBL] [Abstract][Full Text] [Related]
4. [A biomechanical study on internal and external fixation devices for treatment of humeral shaft fracture].
Niu X; Huang F; Cen S; Qin T; Wang R; Shang Z; Liu A; Zheng H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 May; 22(5):516-9. PubMed ID: 18630425
[TBL] [Abstract][Full Text] [Related]
5. Metaphyseal locking plate as an external fixator for open tibial fracture: Clinical outcomes and biomechanical assessment.
Ma CH; Wu CH; Jiang JR; Tu YK; Lin TS
Injury; 2017 Feb; 48(2):501-505. PubMed ID: 27919511
[TBL] [Abstract][Full Text] [Related]
6. Investigating the biomechanical function of the plate-type external fixator in the treatment of tibial fractures: a biomechanical study.
Shi D; Liu K; Zhang H; Wang X; Li G; Zheng L
BMC Musculoskelet Disord; 2020 Feb; 21(1):128. PubMed ID: 32106851
[TBL] [Abstract][Full Text] [Related]
7. Anterolateral and medial locking plate stiffness in distal tibial fracture model.
Yenna ZC; Bhadra AK; Ojike NI; ShahulHameed A; Burden RL; Voor MJ; Roberts CS
Foot Ankle Int; 2011 Jun; 32(6):630-7. PubMed ID: 21733427
[TBL] [Abstract][Full Text] [Related]
8. Unstable proximal extraarticular tibia fractures: a biomechanical evaluation of four methods of fixation.
Peindl RD; Zura RD; Vincent A; Coley ER; Bosse MJ; Sims SH
J Orthop Trauma; 2004 Sep; 18(8):540-5. PubMed ID: 15475850
[TBL] [Abstract][Full Text] [Related]
9. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures--clinical outcome and a finite element study.
Ma CH; Wu CH; Tu YK; Lin TS
Injury; 2013 Aug; 44(8):1097-101. PubMed ID: 23706173
[TBL] [Abstract][Full Text] [Related]
10. Comparative analysis of external locking plate and combined frame external fixator for open distal tibial fractures: a comprehensive assessment of clinical outcomes and financial implications.
Bangura ML; Luo H; Zeng T; Wang M; Lin S; Chunli L
BMC Musculoskelet Disord; 2023 Dec; 24(1):962. PubMed ID: 38082305
[TBL] [Abstract][Full Text] [Related]
11. External Fixation Using a Locking Plate: A Reliable Way in Treating Distal Tibial Fractures.
Zhang J; Ebraheim NA; Li M; He X; Liu J; Zhu L; Yu Y; Siddiqui S
J Orthop Trauma; 2015 Nov; 29(11):e454-8. PubMed ID: 26492454
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.
Strauss EJ; Banerjee D; Kummer FJ; Tejwani NC
J Trauma; 2008 Apr; 64(4):975-81. PubMed ID: 18404064
[TBL] [Abstract][Full Text] [Related]
13. Locking compression plate as an external fixator in the treatment of closed distal tibial fractures.
Zhou Y; Wang Y; Liu L; Zhou Z; Cao X
Int Orthop; 2015 Nov; 39(11):2227-37. PubMed ID: 26183145
[TBL] [Abstract][Full Text] [Related]
14. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop.
Qiu XS; Yuan H; Zheng X; Wang JF; Xiong J; Chen YX
Arch Orthop Trauma Surg; 2014 Mar; 134(3):383-8. PubMed ID: 24362495
[TBL] [Abstract][Full Text] [Related]
15. Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness.
Ang BFH; Chen JY; Yew AKS; Chua SK; Chou SM; Chia SL; Koh JSB; Howe TS
Bone Joint Res; 2017 Apr; 6(4):216-223. PubMed ID: 28420623
[TBL] [Abstract][Full Text] [Related]
16. Finite element analysis comparison of Type 42A2 fracture fixed with external titanium alloy locking plate and traditional external fixation frame.
Fang S; Zhang L; Yang Y; Wang Y; Guo J; Mi L
J Orthop Surg Res; 2023 Oct; 18(1):815. PubMed ID: 37907959
[TBL] [Abstract][Full Text] [Related]
17. External fixation using locking plate in distal tibial fracture: a finite element analysis.
Zhang J; Ebraheim N; Li M; He X; Schwind J; Liu J; Zhu L
Eur J Orthop Surg Traumatol; 2015 Aug; 25(6):1099-104. PubMed ID: 25697487
[TBL] [Abstract][Full Text] [Related]
18. [Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures].
Wu G; Luo X; Tan L; Lin X; Wu C; Guo Y; Zhong Z
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Nov; 27(11):1291-5. PubMed ID: 24501884
[TBL] [Abstract][Full Text] [Related]
19. Metaphyseal locking compression plate as an external fixator for the distal tibia.
Tulner SA; Strackee SD; Kloen P
Int Orthop; 2012 Sep; 36(9):1923-7. PubMed ID: 22648557
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS
Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]