These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 28106806)

  • 1. UHF Signal Processing and Pattern Recognition of Partial Discharge in Gas-Insulated Switchgear Using Chromatic Methodology.
    Wang X; Li X; Rong M; Xie D; Ding D; Wang Z
    Sensors (Basel); 2017 Jan; 17(1):. PubMed ID: 28106806
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improving the Error of Time Differences of Arrival on Partial Discharges Measurement in Gas-Insulated Switchgear.
    Jiang J; Wang K; Zhang C; Chen M; Zheng H; Albarracín R
    Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30469445
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Study on the application of an ultra-high-frequency fractal antenna to partial discharge detection in switchgears.
    Yao C; Chen P; Huang C; Chen Y; Qiao P
    Sensors (Basel); 2013 Dec; 13(12):17362-78. PubMed ID: 24351641
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Partial Discharge Recognition with a Multi-Resolution Convolutional Neural Network.
    Li G; Wang X; Li X; Yang A; Rong M
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30340354
    [TBL] [Abstract][Full Text] [Related]  

  • 5. One-Shot Learning for Partial Discharge Diagnosis Using Ultra-High-Frequency Sensor in Gas-Insulated Switchgear.
    Tuyet-Doan VN; Do TD; Tran-Thi ND; Youn YW; Kim YH
    Sensors (Basel); 2020 Sep; 20(19):. PubMed ID: 32998406
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Novel Method for Pattern Recognition of GIS Partial Discharge via Multi-Information Ensemble Learning.
    Jing Q; Yan J; Lu L; Xu Y; Yang F
    Entropy (Basel); 2022 Jul; 24(7):. PubMed ID: 35885177
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Application of UHF Sensors in Power System Equipment for Partial Discharge Detection: A Review.
    Chai H; Phung BT; Mitchell S
    Sensors (Basel); 2019 Feb; 19(5):. PubMed ID: 30823431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Novel Approach for Partial Discharge Measurements on GIS Using HFCT Sensors.
    Rodrigo Mor A; Castro Heredia LC; Muñoz FA
    Sensors (Basel); 2018 Dec; 18(12):. PubMed ID: 30567382
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of HFCT and UHF sensors in on-line partial discharge measurements for insulation diagnosis of high voltage equipment.
    Álvarez F; Garnacho F; Ortego J; Sánchez-Urán MÁ
    Sensors (Basel); 2015 Mar; 15(4):7360-87. PubMed ID: 25815452
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Field Applications of Ultra High Frequency Techniques for Defect Detection in GIS.
    Xiong J; Wang Y; Ma GM; Zhang Q; Zheng SS
    Sensors (Basel); 2018 Jul; 18(8):. PubMed ID: 30049935
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of a New Built-in UHF Multi-Frequency Antenna Sensor for Partial Discharge Detection in High-Voltage Switchgears.
    Zhang X; Cheng Z; Gui Y
    Sensors (Basel); 2016 Jul; 16(8):. PubMed ID: 27472331
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study of the Influence of Winding and Sensor Design on Ultra-High Frequency Partial Discharge Signals in Power Transformers.
    Beura CP; Beltle M; Tenbohlen S
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32911783
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Flexible Planar Monopole Built-in GIS PD Sensor Based on Meandering Technology.
    Zhang S; Zhang G; Lu C; Tian H; Liu J; Zhang X
    Sensors (Basel); 2022 May; 22(11):. PubMed ID: 35684756
    [TBL] [Abstract][Full Text] [Related]  

  • 14. PD Flexible Built-In High-Sensitivity Elliptical Monopole Antenna Sensor.
    Zhang H; Zhang G; Zhang X; Tian H; Lu C; Liu J; Zhang Y
    Sensors (Basel); 2022 Jul; 22(13):. PubMed ID: 35808486
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Novel Partial Discharge Localization Method in Substation Based on a Wireless UHF Sensor Array.
    Li Z; Luo L; Zhou N; Sheng G; Jiang X
    Sensors (Basel); 2017 Aug; 17(8):. PubMed ID: 28820444
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnosis of Partial Discharge Based on the Air Components for the 10 kV Air-Insulated Switchgear.
    Tan Q; Zhang T; Wu S; Gao J; Song B
    Sensors (Basel); 2022 Mar; 22(6):. PubMed ID: 35336566
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Comparison of Partial Discharge Sensors for Natural Gas Insulated High Voltage Equipment.
    Widger P; Carr D; Hills M; Reid A
    Sensors (Basel); 2020 Aug; 20(16):. PubMed ID: 32784863
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection of Partial Discharge Sources Using UHF Sensors and Blind Signal Separation.
    Boya C; Robles G; Parrado-Hernández E; Ruiz-Llata M
    Sensors (Basel); 2017 Nov; 17(11):. PubMed ID: 29140267
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optical partial discharge diagnostic in SF
    Ren M; Song B; Zhuang T; Yang S
    ISA Trans; 2018 Apr; 75():247-257. PubMed ID: 29475605
    [TBL] [Abstract][Full Text] [Related]  

  • 20. GIS Partial Discharge Pattern Recognition Based on a Novel Convolutional Neural Networks and Long Short-Term Memory.
    Liu T; Yan J; Wang Y; Xu Y; Zhao Y
    Entropy (Basel); 2021 Jun; 23(6):. PubMed ID: 34207466
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.