475 related articles for article (PubMed ID: 28111197)
1. Radiation Cataractogenesis: The Progression of Our Understanding and Its Clinical Consequences.
Khan DZ; Lacasse MC; Khan R; Murphy KJ
J Vasc Interv Radiol; 2017 Mar; 28(3):412-419. PubMed ID: 28111197
[TBL] [Abstract][Full Text] [Related]
2. Optimizing Radiation Safety in the Cardiac Catheterization Laboratory: A Practical Approach.
Christopoulos G; Makke L; Christakopoulos G; Kotsia A; Rangan BV; Roesle M; Haagen D; Kumbhani DJ; Chambers CE; Kapadia S; Mahmud E; Banerjee S; Brilakis ES
Catheter Cardiovasc Interv; 2016 Feb; 87(2):291-301. PubMed ID: 26526181
[TBL] [Abstract][Full Text] [Related]
3. Occupational radiation exposure in the electrophysiology laboratory with a focus on personnel with reproductive potential and during pregnancy: A European Heart Rhythm Association (EHRA) consensus document endorsed by the Heart Rhythm Society (HRS).
Sarkozy A; De Potter T; Heidbuchel H; Ernst S; Kosiuk J; Vano E; Picano E; Arbelo E; Tedrow U;
Europace; 2017 Dec; 19(12):1909-1922. PubMed ID: 29126278
[No Abstract] [Full Text] [Related]
4. Occupational Exposure and Adverse Effects in the Radiologic Interventional Setting.
Walden C
Radiol Technol; 2016; 87(4):460-4. PubMed ID: 26952068
[No Abstract] [Full Text] [Related]
5. Occupational Health Risks in Cardiac Catheterization Laboratory Workers.
Andreassi MG; Piccaluga E; Guagliumi G; Del Greco M; Gaita F; Picano E
Circ Cardiovasc Interv; 2016 Apr; 9(4):e003273. PubMed ID: 27072525
[TBL] [Abstract][Full Text] [Related]
6. Risk for radiation-induced cataract for staff in interventional cardiology: is there reason for concern?
Ciraj-Bjelac O; Rehani MM; Sim KH; Liew HB; Vano E; Kleiman NJ
Catheter Cardiovasc Interv; 2010 Nov; 76(6):826-34. PubMed ID: 20549683
[TBL] [Abstract][Full Text] [Related]
7. Radioprotection Measures during the Learning Curve with Hybrid Operating Rooms.
Fidalgo Domingos L; San Norberto García EM; Gutiérrez Castillo D; Flota Ruiz C; Estévez Fernández I; Vaquero Puerta C
Ann Vasc Surg; 2018 Jul; 50():253-258. PubMed ID: 29501596
[TBL] [Abstract][Full Text] [Related]
8. Risk of cataract among interventional cardiologists and catheterization lab staff: A systematic review and meta-analysis.
Elmaraezy A; Ebraheem Morra M; Tarek Mohammed A; Al-Habaa A; Elgebaly A; Abdelmotaleb Ghazy A; Khalil AM; Tien Huy N; Hirayama K
Catheter Cardiovasc Interv; 2017 Jul; 90(1):1-9. PubMed ID: 28500744
[TBL] [Abstract][Full Text] [Related]
9. Effectiveness of Attaching a Lead Drape to a Radioprotective Shield for CT Fluoroscopy-Guided Procedures.
Hasegawa T; Shimizu H; Asai T; Furuya Y; Hattori H; Inaba Y
J Vasc Interv Radiol; 2024 Jun; 35(6):936-938. PubMed ID: 38789207
[No Abstract] [Full Text] [Related]
10. EAPCI focus on the WEAPCI survey on radiation exposure and regulations in European catheterisation laboratories Julinda Mehilli, Chairwoman.
Windecker S; Haude M; Baumbach A
EuroIntervention; 2016 Jan; 11(9):980. PubMed ID: 27186615
[No Abstract] [Full Text] [Related]
11. Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial.
Vlastra W; Delewi R; Sjauw KD; Beijk MA; Claessen BE; Streekstra GJ; Bekker RJ; van Hattum JC; Wykrzykowska JJ; Vis MM; Koch KT; de Winter RJ; Piek JJ; Henriques JPS
Circ Cardiovasc Interv; 2017 Nov; 10(11):. PubMed ID: 29089313
[TBL] [Abstract][Full Text] [Related]
12. High Radiation Exposure of the Imaging Specialist During Structural Heart Interventions With Echocardiographic Guidance.
Salaun E; Carles S; Bigand E; Pankert M; Aldebert P; Jaussaud N; Theron A; Cuisset T; Lambert M; Grisoli D; Franceschi F; Avierinos JF; Collart F; Deharo JC; Bonnet JL; Habib G
JACC Cardiovasc Interv; 2017 Mar; 10(6):626-627. PubMed ID: 28335903
[No Abstract] [Full Text] [Related]
13. Clinical Evaluation of Protective Garments with Respect to Garment Characteristics and Manufacturer Label Information.
Lichliter A; Weir V; Heithaus RE; Gipson S; Syed A; West J; Rees C
J Vasc Interv Radiol; 2017 Jan; 28(1):148-155. PubMed ID: 27789076
[TBL] [Abstract][Full Text] [Related]
14. Head and Neck Radiation Dose and Radiation Safety for Interventional Physicians.
Fetterly K; Schueler B; Grams M; Sturchio G; Bell M; Gulati R
JACC Cardiovasc Interv; 2017 Mar; 10(5):520-528. PubMed ID: 28279321
[TBL] [Abstract][Full Text] [Related]
15. Can Aprons Be Properly Evaluated for Their Protective Quality without In-House Validation?
Weissenborn M; Heithaus E; Weir V; Onofrio A; Rees C
J Vasc Interv Radiol; 2016 Dec; 27(12):1933-1935.e2. PubMed ID: 27886959
[No Abstract] [Full Text] [Related]
16. Live Without Regret.
Marx MV
Tech Vasc Interv Radiol; 2018 Mar; 21(1):1. PubMed ID: 29471993
[No Abstract] [Full Text] [Related]
17. Radiation-associated lens changes in the cardiac catheterization laboratory: Results from the IC-CATARACT (CATaracts Attributed to RAdiation in the CaTh lab) study.
Karatasakis A; Brilakis HS; Danek BA; Karacsonyi J; Martinez-Parachini JR; Nguyen-Trong PJ; Alame AJ; Roesle MK; Rangan BV; Rosenfield K; Mehran R; Mahmud E; Chambers CE; Banerjee S; Brilakis ES
Catheter Cardiovasc Interv; 2018 Mar; 91(4):647-654. PubMed ID: 28707381
[TBL] [Abstract][Full Text] [Related]
18. Caution: Not seeing may be believing.
Balter S
Catheter Cardiovasc Interv; 2010 Nov; 76(6):835. PubMed ID: 21104773
[No Abstract] [Full Text] [Related]
19. The Eyes Have It.
Machan L
Tech Vasc Interv Radiol; 2018 Mar; 21(1):21-25. PubMed ID: 29471996
[TBL] [Abstract][Full Text] [Related]
20. Radiation-Induced Cataractogenesis: A Critical Literature Review for the Interventional Radiologist.
Seals KF; Lee EW; Cagnon CH; Al-Hakim RA; Kee ST
Cardiovasc Intervent Radiol; 2016 Feb; 39(2):151-60. PubMed ID: 26404628
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]