These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 2811346)

  • 1. Hydraulic input impedance measurements in physical models of the arterial wall.
    Papageorgiou GL; Jones NB
    J Biomed Eng; 1989 Nov; 11(6):471-7. PubMed ID: 2811346
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Using hydraulic input impedance in determination of changes in the arteries of different calibre].
    Naumov AIu; Balashov SA; Mel'kumiants AM
    Ross Fiziol Zh Im I M Sechenova; 2003 Dec; 89(12):1507-15. PubMed ID: 14870488
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Scatter in input impedance spectrum may result from the elastic nonlinearity of the arterial wall.
    Stergiopulos N; Meister JJ; Westerhof N
    Am J Physiol; 1995 Oct; 269(4 Pt 2):H1490-5. PubMed ID: 7485585
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative evaluation of arterial pulsatile flow and pressure, applying impedance plethysmography to a human arterial model incorporating anatomical branching and scale.
    Semnani R; Smith RE
    Comput Methods Programs Biomed; 1987 Aug; 25(1):13-20. PubMed ID: 3652671
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulsatile pressure-flow relations and pulse-wave propagation in the umbilical circulation of fetal sheep.
    Adamson SL; Whiteley KJ; Langille BL
    Circ Res; 1992 Apr; 70(4):761-72. PubMed ID: 1551202
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of mean pressure on aortic impedance and reflections in the systemic arterial system.
    Alexander J; Burkhoff D; Schipke J; Sagawa K
    Am J Physiol; 1989 Sep; 257(3 Pt 2):H969-78. PubMed ID: 2782451
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impedance and wave reflection in arterial system: simulation with geometrically tapered T-tubes.
    Chang KC; Tseng YZ; Kuo TS; Chen HI
    Med Biol Eng Comput; 1995 Sep; 33(5):652-60. PubMed ID: 8523906
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Variation of wave speed determined by the PU-loop with proximity to a reflection site.
    Li Y; Borlotti A; Parker KH; Khir AW
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():199-202. PubMed ID: 22254284
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Manipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: relationship to input impedance.
    Murgo JP; Westerhof N; Giolma JP; Altobelli SA
    Circulation; 1981 Jan; 63(1):122-32. PubMed ID: 7438386
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Input impedance of distributed arterial structures as used in investigations of underlying concepts in arterial haemodynamics.
    Avolio A
    Med Biol Eng Comput; 2009 Feb; 47(2):143-51. PubMed ID: 18949501
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The electrical impedance of pulsatile blood flowing through rigid tubes: a theoretical investigation.
    Gaw RL; Cornish BH; Thomas BJ
    IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):721-7. PubMed ID: 18270009
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wave transmission and input impedance of a model of skeletal muscle microvasculature.
    Frasch HF; Kresh JY; Noordergraaf A
    Ann Biomed Eng; 1994; 22(1):45-57. PubMed ID: 8060026
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The arterial Windkessel.
    Westerhof N; Lankhaar JW; Westerhof BE
    Med Biol Eng Comput; 2009 Feb; 47(2):131-41. PubMed ID: 18543011
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noninvasive (input) impedance, pulse wave velocity, and wave reflection in healthy middle-aged men and women.
    Segers P; Rietzschel ER; De Buyzere ML; Vermeersch SJ; De Bacquer D; Van Bortel LM; De Backer G; Gillebert TC; Verdonck PR;
    Hypertension; 2007 Jun; 49(6):1248-55. PubMed ID: 17404183
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impedance matching at arterial bifurcations.
    Brown N
    J Biomech; 1993 Jan; 26(1):59-67. PubMed ID: 8423169
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analytical relationship between arterial input impedance and the three-element Windkessel series resistance.
    Gnudi G
    Med Biol Eng Comput; 1998 Jul; 36(4):480-4. PubMed ID: 10198533
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effective length of the arterial circulation determined in the dog by aid of a model of the systemic input impedance.
    Burattini R; Di Carlo S
    IEEE Trans Biomed Eng; 1988 Jan; 35(1):53-61. PubMed ID: 3338812
    [No Abstract]   [Full Text] [Related]  

  • 18. Arterial stiffness and wave reflections in marathon runners.
    Vlachopoulos C; Kardara D; Anastasakis A; Baou K; Terentes-Printzios D; Tousoulis D; Stefanadis C
    Am J Hypertens; 2010 Sep; 23(9):974-9. PubMed ID: 20489686
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical achievements of impedance analysis.
    Mitchell GF
    Med Biol Eng Comput; 2009 Feb; 47(2):153-63. PubMed ID: 18853214
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulmonary vascular impedance and wave reflections in the hypoxic calf.
    Zuckerman BD; Orton EC; Latham LP; Barbiere CC; Stenmark KR; Reeves JT
    J Appl Physiol (1985); 1992 Jun; 72(6):2118-27. PubMed ID: 1629064
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.