These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 28113550)

  • 21. Improving signal-to-noise ratios of liquid chromatography-tandem mass spectrometry peaks using noise frequency spectrum modification between two consecutive matched-filtering procedures.
    Wang SC; Huang CM; Chiang SM
    J Chromatogr A; 2007 Aug; 1161(1-2):192-7. PubMed ID: 17588590
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optimal filter bandwidth for pulse oximetry.
    Stuban N; Niwayama M
    Rev Sci Instrum; 2012 Oct; 83(10):104708. PubMed ID: 23126791
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Digital Butterworth filter for subtracting noise from low magnitude surface electromyogram.
    Mello RG; Oliveira LF; Nadal J
    Comput Methods Programs Biomed; 2007 Jul; 87(1):28-35. PubMed ID: 17548125
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optimal digital filters for analyzing the mid-latency auditory P50 event-related potential in patients with Alzheimer's disease.
    Liljander S; Holm A; Keski-Säntti P; Partanen JV
    J Neurosci Methods; 2016 Jun; 266():50-67. PubMed ID: 27015794
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Optimization of speed-of-sound estimation from noisy ultrasonic signals.
    Ophir J; Yazdi Y; Lin TS; Shattuck DP
    IEEE Trans Ultrason Ferroelectr Freq Control; 1989; 36(1):16-24. PubMed ID: 18284945
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Signal denoising and ultrasonic flaw detection via overcomplete and sparse representations.
    Zhang GM; Harvey DM; Braden DR
    J Acoust Soc Am; 2008 Nov; 124(5):2963-72. PubMed ID: 19045784
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Improvement of the fringe analysis algorithm for wavelength scanning interferometry based on filter parameter optimization.
    Zhang T; Gao F; Muhamedsalih H; Lou S; Martin H; Jiang X
    Appl Opt; 2018 Mar; 57(9):2227-2234. PubMed ID: 29604017
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An Adaptive Filter for the Removal of Drifting Sinusoidal Noise Without a Reference.
    Kelly JW; Siewiorek DP; Smailagic A; Wang W
    IEEE J Biomed Health Inform; 2016 Jan; 20(1):213-21. PubMed ID: 25474814
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cluster-enhanced sparse approximation of overlapping ultrasonic echoes.
    Mor E; Aladjem M; Azoulay A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Feb; 62(2):373-86. PubMed ID: 25643086
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A low-distortion filter method to reject muscle noise in multi-lead electrocardiogram systems.
    Wei D; Harasawa E; Hosaka H
    Front Med Biol Eng; 1999; 9(4):315-30. PubMed ID: 10718669
    [TBL] [Abstract][Full Text] [Related]  

  • 31. SNR Degradation in Undersampled Phase Measurement Systems.
    Salido-Monzú D; Meca-Meca FJ; Martín-Gorostiza E; Lázaro-Galilea JL
    Sensors (Basel); 2016 Oct; 16(10):. PubMed ID: 27783033
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accelerated image reconstruction using extrapolated Tikhonov filtering for photoacoustic tomography.
    Gutta S; Kalva SK; Pramanik M; Yalavarthy PK
    Med Phys; 2018 Jun; ():. PubMed ID: 29856489
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Speckle reduction by energy time-frequency filtering.
    Izquierdo MA; Hernández MG; Anaya JJ; Martinez O
    Ultrasonics; 2004 Apr; 42(1-9):843-6. PubMed ID: 15047394
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Singular value decomposition based impulsive noise reduction in multi-frequency phase-sensitive demodulation of electrical impedance tomography.
    Hao Z; Cui Z; Yue S; Wang H
    Rev Sci Instrum; 2018 Jun; 89(6):064702. PubMed ID: 29960571
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Bias and variance in the estimate of the Doppler frequency induced by a wall motion filter.
    Willemetz JC; Nowicki A; Meister JJ; De Palma F; Pante G
    Ultrason Imaging; 1989 Jul; 11(3):215-25. PubMed ID: 2675453
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The practical significance of two-dimensional deconvolution in echography.
    Jeurens TJ; Somer JC; Smeets FA; Hoeks AP
    Ultrason Imaging; 1987 Apr; 9(2):106-16. PubMed ID: 3318076
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Digital filter design for electrophysiological data--a practical approach.
    Widmann A; Schröger E; Maess B
    J Neurosci Methods; 2015 Jul; 250():34-46. PubMed ID: 25128257
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Adaptive digital notch filter design on the unit circle for the removal of powerline noise from biomedical signals.
    Ferdjallah M; Barr RE
    IEEE Trans Biomed Eng; 1994 Jun; 41(6):529-36. PubMed ID: 7927372
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Perception of temporally filtered X-ray fluoroscopy images.
    Wilson DL; Jabri KN; Aufrichtig R
    IEEE Trans Med Imaging; 1999 Jan; 18(1):22-31. PubMed ID: 10193694
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Optimization of buffer rod geometry for ultrasonic sensors with reference path.
    Hoppe N; Püttmer A; Hauptmann P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Feb; 50(2):170-8. PubMed ID: 12625589
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.