These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 28113953)

  • 1. Towards High Throughput Cell Growth Screening: A New CMOS 8 × 8 Biosensor Array for Life Science Applications.
    Nabovati G; Ghafar-Zadeh E; Letourneau A; Sawan M
    IEEE Trans Biomed Circuits Syst; 2017 Apr; 11(2):380-391. PubMed ID: 28113953
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wide Input Dynamic Range Fully Integrated Capacitive Sensor for Life Science Applications.
    Tabrizi HO; Farhanieh O; Owen Q; Magierowski S; Ghafar-Zadeh E
    IEEE Trans Biomed Circuits Syst; 2021 Apr; 15(2):339-350. PubMed ID: 33891555
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A High Dynamic Range Dual 8×16 Capacitive Sensor Array for Life Science Applications.
    Tabrizi HO; Forouhi S; Ghafar-Zadeh E
    IEEE Trans Biomed Circuits Syst; 2022 Dec; PP():. PubMed ID: 37015455
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Smart Cell Culture Monitoring and Drug Test Platform Using CMOS Capacitive Sensor Array.
    Nabovati G; Ghafar-Zadeh E; Letourneau A; Sawan M
    IEEE Trans Biomed Eng; 2019 Apr; 66(4):1094-1104. PubMed ID: 30139044
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A 16 × 16 CMOS Capacitive Biosensor Array Towards Detection of Single Bacterial Cell.
    Couniot N; Francis LA; Flandre D
    IEEE Trans Biomed Circuits Syst; 2016 Apr; 10(2):364-74. PubMed ID: 25974947
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Label-free CMOS bio sensor with on-chip noise reduction scheme for real-time quantitative monitoring of biomolecules.
    Seong-Jin Kim ; Euisik Yoon
    IEEE Trans Biomed Circuits Syst; 2012 Jun; 6(3):189-96. PubMed ID: 23853141
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tracking cancer cell proliferation on a CMOS capacitance sensor chip.
    Prakash SB; Abshire P
    Biosens Bioelectron; 2008 May; 23(10):1449-57. PubMed ID: 18281207
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An autonomous CMOS hysteretic sensor for the detection of desorption-free DNA hybridization.
    Lee KH; Choi SH; Lee JO; Sohn MJ; Yoon JB; Cho GH
    Biosens Bioelectron; 2011 Jul; 26(11):4591-5. PubMed ID: 21592770
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A New Fully Differential CMOS Capacitance to Digital Converter for Lab-on-Chip Applications.
    Nabovati G; Ghafar-Zadeh E; Mirzaei M; Ayala-Charca G; Awwad F; Sawan M
    IEEE Trans Biomed Circuits Syst; 2015 Jun; 9(3):353-61. PubMed ID: 25134090
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Toward High Throughput Core-CBCM CMOS Capacitive Sensors for Life Science Applications: A Novel Current-Mode for High Dynamic Range Circuitry.
    Forouhi S; Dehghani R; Ghafar-Zadeh E
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30304843
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dielectrophoresis-based integrated Lab-on-Chip for nano and micro-particles manipulation and capacitive detection.
    Miled MA; Massicotte G; Sawan M
    IEEE Trans Biomed Circuits Syst; 2012 Apr; 6(2):120-32. PubMed ID: 23852977
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Multi-Functional CMOS Biosensor Array With On-Chip DEP-Assisted Sensing for Rapid Low-Concentration Analyte Detection and Close-Loop Particle Manipulation With No External Electrodes.
    Lee D; Jung D; Jiang F; Junek GV; Park J; Liu H; Kong Y; Wang A; Kim Y; Choi KS; Wang J; Wang H
    IEEE Trans Biomed Circuits Syst; 2023 Dec; 17(6):1214-1226. PubMed ID: 38096094
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A CMOS-based microelectrode array for interaction with neuronal cultures.
    Hafizovic S; Heer F; Ugniwenko T; Frey U; Blau A; Ziegler C; Hierlemann A
    J Neurosci Methods; 2007 Aug; 164(1):93-106. PubMed ID: 17540452
    [TBL] [Abstract][Full Text] [Related]  

  • 14. One-chip electronic detection of DNA hybridization using precision impedance-based CMOS array sensor.
    Lee KH; Lee JO; Sohn MJ; Lee B; Choi SH; Kim SK; Yoon JB; Cho GH
    Biosens Bioelectron; 2010 Dec; 26(4):1373-9. PubMed ID: 20692155
    [TBL] [Abstract][Full Text] [Related]  

  • 15. LTCC Packaged Ring Oscillator Based Sensor for Evaluation of Cell Proliferation.
    Kilpijärvi J; Halonen N; Sobocinski M; Hassinen A; Senevirathna B; Uvdal K; Abshire P; Smela E; Kellokumpu S; Juuti J; Lloyd Spetz A
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30301258
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A digital CMOS-based 24×16 sensor array platform for fully automatic electrochemical DNA detection.
    Kruppa P; Frey A; Kuehne I; Schienle M; Persike N; Kratzmueller T; Hartwich G; Schmitt-Landsiedel D
    Biosens Bioelectron; 2010 Dec; 26(4):1414-9. PubMed ID: 20729052
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A CMOS Pixelated Nanocapacitor Biosensor Platform for High-Frequency Impedance Spectroscopy and Imaging.
    Widdershoven F; Cossettini A; Laborde C; Bandiziol A; van Swinderen PP; Lemay SG; Selmi L
    IEEE Trans Biomed Circuits Syst; 2018 Dec; 12(6):1369-1382. PubMed ID: 30059320
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An electronic DNA sensor chip using integrated capacitive read-out circuit.
    Lee B; Lee KH; Lee JO; Sohn MJ; Choi SH; Wang SW; Yoon JB; Cho GH
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():6547-50. PubMed ID: 21096503
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Multimodal and Multifunctional CMOS Cellular Interfacing Array for Digital Physiology and Pathology Featuring an Ultra Dense Pixel Array and Reconfigurable Sampling Rate.
    Wang AY; Sheng Y; Li W; Jung D; Junek GV; Liu H; Park J; Lee D; Wang M; Maharjan S; Kumashi S; Hao J; Zhang YS; Eggan K; Wang H
    IEEE Trans Biomed Circuits Syst; 2022 Dec; 16(6):1057-1074. PubMed ID: 36417722
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A multi-channel femtoampere-sensitivity conductometric array for biosensing applications.
    Gore A; Chakrabartty S; Pal S; Alocilja E
    Conf Proc IEEE Eng Med Biol Soc; 2006; Suppl():6489-92. PubMed ID: 17959433
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.