These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

954 related articles for article (PubMed ID: 28130679)

  • 1. In vivo investigation of ear canal pulse oximetry during hypothermia.
    Budidha K; Kyriacou PA
    J Clin Monit Comput; 2018 Feb; 32(1):97-107. PubMed ID: 28130679
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigation of photoplethysmography and arterial blood oxygen saturation from the ear-canal and the finger under conditions of artificially induced hypothermia.
    Budidha K; Kyriacou PA
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():7954-7. PubMed ID: 26738137
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation.
    Budidha K; Kyriacou PA
    Physiol Meas; 2014 Feb; 35(2):111-28. PubMed ID: 24399082
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.
    Abay TY; Kyriacou PA
    J Clin Monit Comput; 2018 Jun; 32(3):447-455. PubMed ID: 28547651
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers.
    Shafique M; Kyriacou PA
    Physiol Meas; 2012 Dec; 33(12):2065-78. PubMed ID: 23171523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.
    Shafique M; Kyriacou PA; Pal SK
    Med Biol Eng Comput; 2012 Jun; 50(6):575-83. PubMed ID: 22555629
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulse oximetry in the oesophagus.
    Kyriacou PA
    Physiol Meas; 2006 Jan; 27(1):R1-35. PubMed ID: 16365505
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Devepopment of an optical probe to investigate the suitability of measuring photoplethysmographs and blood oxygen saturation from the human auditory canal.
    Budidha K; Kyriacou PA
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1736-9. PubMed ID: 24110042
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.
    Kyriacou PA; Powell S; Langford RM; Jones DP
    Physiol Meas; 2002 Aug; 23(3):533-45. PubMed ID: 12214761
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    J Clin Monit Comput; 2011 Aug; 25(4):245-55. PubMed ID: 21953382
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation of the human oesophagus as a new monitoring site for blood oxygen saturation.
    Kyriacou PA; Moye AR; Choi DM; Langford RM; Jones DP
    Physiol Meas; 2001 Feb; 22(1):223-32. PubMed ID: 11236883
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion.
    Abay TY; Kyriacou PA
    IEEE Trans Biomed Eng; 2015 Sep; 62(9):2187-95. PubMed ID: 25838515
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of oesophageal reflectance pulse oximetry in major burns patients.
    Pal SK; Kyriacou PA; Kumaran S; Fadheel S; Emamdee R; Langford RM; Jones DP
    Burns; 2005 May; 31(3):337-41. PubMed ID: 15774290
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Esophageal pulse oximetry utilizing reflectance photoplethysmography.
    Kyriacou PA; Powell S; Langford RM; Jones DP
    IEEE Trans Biomed Eng; 2002 Nov; 49(11):1360-8. PubMed ID: 12450366
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Novel Photoplethysmography Sensor for Vital Signs Monitoring from the Human Trachea.
    May JM; Phillips JP; Fitchat T; Ramaswamy S; Snidvongs S; Kyriacou PA
    Biosensors (Basel); 2019 Oct; 9(4):. PubMed ID: 31581652
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry.
    Alkhoury L; Choi JW; Wang C; Rajasekar A; Acharya S; Mahoney S; Shender BS; Hrebien L; Kam M
    J Clin Monit Comput; 2021 Aug; 35(4):797-813. PubMed ID: 32556842
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR).
    Bradke B; Everman B
    Biosensors (Basel); 2020 Apr; 10(4):. PubMed ID: 32260393
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigation of photoplethysmographs from the anterior fontanelle of neonates.
    May JM; Kyriacou PA; Honsel M; Petros AJ
    Physiol Meas; 2014 Oct; 35(10):1961-73. PubMed ID: 25229803
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation of photoplethysmography, laser doppler flowmetry and near infrared spectroscopy during induced thermal stress.
    Budidha K; Abay TY; Kyriacou PA
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():6417-20. PubMed ID: 26737761
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 48.