These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 28131351)

  • 1. Hemolysis From Drawing Laboratory Work Through an Intravenous Catheter Site.
    Reynolds D
    J Emerg Nurs; 2017 Jan; 43(1):6. PubMed ID: 28131351
    [No Abstract]   [Full Text] [Related]  

  • 2. The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples.
    Grant MS
    J Emerg Nurs; 2003 Apr; 29(2):116-21. PubMed ID: 12660692
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Risk of hemolysis in blood sampling from peripheral intravenous catheter: a literature review].
    Danielis M
    Prof Inferm; 2014; 67(3):166-72. PubMed ID: 25392029
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nursing blood specimen collection techniques and hemolysis rates in an emergency department: analysis of venipuncture versus intravenous catheter collection techniques.
    Lowe G; Stike R; Pollack M; Bosley J; O'Brien P; Hake A; Landis G; Billings N; Gordon P; Manzella S; Stover T
    J Emerg Nurs; 2008 Feb; 34(1):26-32. PubMed ID: 18237663
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Single-Center Prospective Study of the Effects of Different Methods of Phlebotomy in the Emergency Department on Blood Sample Hemolysis Rates.
    Ersoy S; Ilanbey B;
    J Emerg Nurs; 2023 Jan; 49(1):134-139. PubMed ID: 36137822
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples.
    Kennedy C; Angermuller S; King R; Noviello S; Walker J; Warden J; Vang S
    J Emerg Nurs; 1996 Dec; 22(6):566-9. PubMed ID: 9060320
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department.
    Dugan L; Leech L; Speroni KG; Corriher J
    J Emerg Nurs; 2005 Aug; 31(4):338-45. PubMed ID: 16126097
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of processes, outcomes, and use of midline peripheral catheters for the purpose of blood collection.
    Penoyer D; Bennett M; Geddie PI; Nugent A; Volkerson T
    Br J Nurs; 2021 Jan; 30(2):S24-S32. PubMed ID: 33529105
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prevention of hemolysis in blood samples collected from intravenous catheters.
    Lippi G; Avanzini P; Cervellin G
    Clin Biochem; 2013 May; 46(7-8):561-4. PubMed ID: 23391635
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of butterfly needles to draw blood is independently associated with marked reduction in hemolysis compared to intravenous catheter.
    Wollowitz A; Bijur PE; Esses D; John Gallagher E
    Acad Emerg Med; 2013 Nov; 20(11):1151-5. PubMed ID: 24238318
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Blood collection from intravenous lines: is one drawing site better than others?
    Lippi G; Avanzini P; Aloe R; Cervellin G
    Lab Med; 2014; 45(2):172-5. PubMed ID: 24869000
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Can a blood sample for diagnostic exams be drawn from a peripheral venous catheter?].
    Benso S
    Assist Inferm Ric; 2015; 34(2):86-92. PubMed ID: 26228505
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemolysis of coagulation specimens: a comparative study of intravenous draw methods.
    Stauss M; Sherman B; Pugh L; Parone D; Looby-Rodriguez K; Bell A; Reed CR
    J Emerg Nurs; 2012 Jan; 38(1):15-21. PubMed ID: 22226132
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters.
    Heiligers-Duckers C; Peters NALR; van Dijck JJP; Hoeijmakers JMJ; Janssen MJW
    Clin Biochem; 2013 Aug; 46(12):1142-1144. PubMed ID: 23603143
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The relationship between vacuum and hemolysis during catheter blood collection: a retrospective analysis of six large cohorts.
    Mrazek C; Simundic AM; Wiedemann H; Krahmer F; Felder TK; Kipman U; Hoppe U; Haschke-Becher E; Cadamuro J
    Clin Chem Lab Med; 2017 Jul; 55(8):1129-1134. PubMed ID: 28107171
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Generalizability and Effectiveness of Butterfly Phlebotomy in Reducing Hemolysis.
    Barnaby DP; Wollowitz A; White D; Pearlman S; Davitt M; Holihan L; Bijur P; Gallagher EJ
    Acad Emerg Med; 2016 Feb; 23(2):204-7. PubMed ID: 26766429
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of peripheral IV based blood collection on catheter dwell time, blood collection, and patient response.
    Mulloy DF; Lee SM; Gregas M; Hoffman KE; Ashley SW
    Appl Nurs Res; 2018 Apr; 40():76-79. PubMed ID: 29579503
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Factors affecting the risk of blood bank specimen hemolysis.
    Tanabe P; Kyriacou DN; Garland F
    Acad Emerg Med; 2003 Aug; 10(8):897-900. PubMed ID: 12896895
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Is there interrelationship between percentage of hemolysis and clots in samples of venous blood?].
    Moshkin AV; Sveschinsky ML; Steriopolo NA; Tsaregorodtsev DV
    Klin Lab Diagn; 2017 Feb; 62(2):94-6. PubMed ID: 30615388
    [TBL] [Abstract][Full Text] [Related]  

  • 20. One poke or two: can intravenous catheters provide an acceptable blood sample? A data set presentation, review of previous data sets, and discussion.
    Dietrich H
    J Emerg Nurs; 2014 Nov; 40(6):575-8. PubMed ID: 23333158
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.