These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
8. Whole-body and thoracic bioimpedance measurement: hypertension and hyperhydration in hemodialysis patients. Nescolarde L; Bogónez P; Calpe J; Hernández R; Doñate T; Rosell J Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3593-6. PubMed ID: 18002774 [TBL] [Abstract][Full Text] [Related]
9. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods. Jaffrin MY; Morel H Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172 [TBL] [Abstract][Full Text] [Related]
10. Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial. Hur E; Usta M; Toz H; Asci G; Wabel P; Kahvecioglu S; Kayikcioglu M; Demirci MS; Ozkahya M; Duman S; Ok E Am J Kidney Dis; 2013 Jun; 61(6):957-65. PubMed ID: 23415416 [TBL] [Abstract][Full Text] [Related]
11. Dialysis disequilibrium syndrome: a critical care nursing challenge. Norris MK Dimens Crit Care Nurs; 1982; 1(1):17-21, 63. PubMed ID: 6922768 [No Abstract] [Full Text] [Related]
12. Body fluid volume determination via body composition spectroscopy in health and disease. Moissl UM; Wabel P; Chamney PW; Bosaeus I; Levin NW; Bosy-Westphal A; Korth O; Müller MJ; Ellegård L; Malmros V; Kaitwatcharachai C; Kuhlmann MK; Zhu F; Fuller NJ Physiol Meas; 2006 Sep; 27(9):921-33. PubMed ID: 16868355 [TBL] [Abstract][Full Text] [Related]
13. Bioimpedance technology and optimal fluid management. Daugirdas JT Am J Kidney Dis; 2013 Jun; 61(6):861-4. PubMed ID: 23684491 [No Abstract] [Full Text] [Related]
14. [Assessment of unbalance in water compartments of patients with gestosis]. Galushka SV; Nazarov BF; Vlasenko AV; Meshcheriakov GN; Mitrokhin AA Anesteziol Reanimatol; 2003; (6):35-8. PubMed ID: 14991978 [TBL] [Abstract][Full Text] [Related]
15. Volume overload in dialysis: the elephant in the room, no one can see. Agarwal R Am J Nephrol; 2013; 38(1):75-7. PubMed ID: 23838679 [No Abstract] [Full Text] [Related]
16. Assessment of hypervolemia by cyclic 3'5'-guanosine monophosphate in pediatric patients on hemodialysis. Sitter T; Holzgartner V; Wolfram G; Toepfer M; Klare B; Gerzer R; Schiffl H Nephron; 1999; 83(3):287-8. PubMed ID: 10529644 [No Abstract] [Full Text] [Related]
17. Nutritional status and overhydration: can bioimpedance spectroscopy be useful in haemodialysis patients? Garagarza C; João-Matias P; Sousa-Guerreiro C; Amaral T; Aires I; Ferreira C; Jorge C; Gil C; Ferreira A Nefrologia; 2013; 33(5):667-74. PubMed ID: 24089158 [TBL] [Abstract][Full Text] [Related]