These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 28132981)

  • 1. Difference of Tissue Characteristics Between Early and Late Restenosis After Second-Generation Drug-Eluting Stents Implantation - An Optical Coherence Tomography Study.
    Jinnouchi H; Kuramitsu S; Shinozaki T; Tomoi Y; Hiromasa T; Kobayashi Y; Domei T; Soga Y; Hyodo M; Shirai S; Ando K
    Circ J; 2017 Mar; 81(4):450-457. PubMed ID: 28132981
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Analysis of optical coherence tomography of early and very late stent restenosis after drug-eluting stent implantation].
    Liu ZJ; Shi B; Deng CC; Xu GX; Zhao RZ; Shen CY; Wang ZL; Liu HL
    Zhonghua Yi Xue Za Zhi; 2017 Jun; 97(23):1778-1783. PubMed ID: 28647998
    [No Abstract]   [Full Text] [Related]  

  • 3. In-stent restenosis assessed with frequency domain optical coherence tomography shows smooth coronary arterial healing process in second-generation drug-eluting stents.
    Kajiya T; Yamaguchi H; Takaoka J; Fukunaga K; Arima R; Miyamura A; Ninomiya T; Atsuchi N; Atsuchi Y; Terashima M; Kaneda H; Ohishi M
    Singapore Med J; 2019 Jan; 60(1):48-51. PubMed ID: 29632955
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Morphological differences of tissue characteristics between early, late, and very late restenosis lesions after first generation drug-eluting stent implantation: an optical coherence tomography study.
    Habara M; Terashima M; Nasu K; Kaneda H; Yokota D; Ito T; Kurita T; Teramoto T; Kimura M; Kinoshita Y; Tsuchikane E; Asakura Y; Suzuki T
    Eur Heart J Cardiovasc Imaging; 2013 Mar; 14(3):276-84. PubMed ID: 22945378
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Difference in neointimal appearance between early and late restenosis after sirolimus-eluting stent implantation assessed by optical coherence tomography.
    Ino Y; Kubo T; Kitabata H; Ishibashi K; Tanimoto T; Matsuo Y; Shimamura K; Shiono Y; Orii M; Komukai K; Yamano T; Yamaguchi T; Hirata K; Tanaka A; Mizukoshi M; Imanishi T; Akasaka T
    Coron Artery Dis; 2013 Mar; 24(2):95-101. PubMed ID: 23363984
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of in-stent neoatherosclerosis and tissue characteristics between early and late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study.
    Sabbah M; Kadota K; El-Eraky A; Kamal HM; Abdellah AT; El Hawary A
    Int J Cardiovasc Imaging; 2017 Oct; 33(10):1463-1472. PubMed ID: 28444549
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optical coherence tomographic analysis of drug-eluting in-stent restenosis at different times: A STROBE compliant study.
    Feng C; Zhang P; Han B; Li X; Liu Y; Niu D; Shi Y
    Medicine (Baltimore); 2018 Aug; 97(34):e12117. PubMed ID: 30142870
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Different Neoatherosclerosis Patterns in Drug-Eluting- and Bare-Metal Stent Restenosis - Optical Coherence Tomography Study.
    Nakamura D; Yasumura K; Nakamura H; Matsuhiro Y; Yasumoto K; Tanaka A; Matsunaga-Lee Y; Yano M; Yamato M; Egami Y; Shutta R; Sakata Y; Tanouchi J; Nishino M
    Circ J; 2019 Jan; 83(2):313-319. PubMed ID: 30487370
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characteristics of early versus late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study.
    Song L; Mintz GS; Yin D; Yamamoto MH; Chin CY; Matsumura M; Kirtane AJ; Parikh MA; Moses JW; Ali ZA; Shlofmitz RA; Maehara A
    EuroIntervention; 2017 Jun; 13(3):294-302. PubMed ID: 28320686
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Optical coherence tomographic analysis of in-stent neoatherosclerosis in lesions with restenosis after drug-eluting stent implantation].
    Liu ZJ; Shi B; Deng CC; Xu GX; Zhao RZ; Shen CY; Wang ZL; Liu HL
    Zhonghua Xin Xue Guan Bing Za Zhi; 2018 Jan; 46(1):44-49. PubMed ID: 29374937
    [No Abstract]   [Full Text] [Related]  

  • 11. Evaluation of below-the-knee drug-eluting stents with frequency-domain optical coherence tomography: neointimal hyperplasia and neoatherosclerosis.
    Paraskevopoulos I; Spiliopoulos S; Davlouros P; Karnabatidis D; Katsanos K; Alexopoulos D; Siablis D
    J Endovasc Ther; 2013 Feb; 20(1):80-93. PubMed ID: 23391087
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Association between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation.
    Tada T; Kadota K; Hosogi S; Miyake K; Ohya M; Amano H; Izawa Y; Kanazawa T; Kubo S; Ichinohe T; Hyoudou Y; Hayakawa Y; Sabbah MM; Otsuru S; Hasegawa D; Habara S; Tanaka H; Fuku Y; Katoh H; Goto T; Mitsudo K
    Eur Heart J Cardiovasc Imaging; 2015 Oct; 16(10):1101-11. PubMed ID: 25762559
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation.
    Kang SJ; Mintz GS; Akasaka T; Park DW; Lee JY; Kim WJ; Lee SW; Kim YH; Whan Lee C; Park SW; Park SJ
    Circulation; 2011 Jun; 123(25):2954-63. PubMed ID: 21646494
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Differences in tissue characterization of restenotic neointima between sirolimus-eluting stent and bare-metal stent: integrated backscatter intravascular ultrasound analysis for in-stent restenosis.
    Ando H; Amano T; Takashima H; Harada K; Kitagawa K; Suzuki A; Kunimura A; Shimbo Y; Harada K; Yoshida T; Kato B; Uetani T; Kato M; Matsubara T; Kumagai S; Yoshikawa D; Isobe S; Ishii H; Murohara T
    Eur Heart J Cardiovasc Imaging; 2013 Oct; 14(10):996-1001. PubMed ID: 23341147
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo optical coherence tomography of very late drug-eluting stent thrombosis compared with late in-stent restenosis.
    Miyazaki S; Hiasa Y; Takahashi T; Yano Y; Minami T; Murakami N; Mizobe M; Tobetto Y; Nakagawa T; Chen PM; Ogura R; Miyajima H; Yuba K; Hosokawa S; Kishi K; Ohtani R
    Circ J; 2012; 76(2):390-8. PubMed ID: 22130319
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization of in-stent neointimal tissue components following drug-eluting stent implantation according to the phase of restenosis using a 40-MHz intravascular ultrasound imaging system.
    Araki T; Nakamura M; Sugi K
    J Cardiol; 2014 Dec; 64(6):423-9. PubMed ID: 24794755
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical coherence tomographic observation of in-stent neoatherosclerosis in lesions with more than 50% neointimal area stenosis after second-generation drug-eluting stent implantation.
    Lee SY; Hur SH; Lee SG; Kim SW; Shin DH; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK
    Circ Cardiovasc Interv; 2015 Feb; 8(2):e001878. PubMed ID: 25613674
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Difference of tissue characteristics between early and very late restenosis lesions after bare-metal stent implantation: an optical coherence tomography study.
    Habara M; Terashima M; Nasu K; Kaneda H; Inoue K; Ito T; Kamikawa S; Kurita T; Tanaka N; Kimura M; Kinoshita Y; Tsuchikane E; Matsuo H; Ueno K; Katoh O; Suzuki T
    Circ Cardiovasc Interv; 2011 Jun; 4(3):232-8. PubMed ID: 21610225
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Differences between first-generation and second-generation drug-eluting stent regarding in-stent neoatherosclerosis characteristics: an optical coherence tomography analysis.
    Kobayashi N; Ito Y; Yamawaki M; Araki M; Sakai T; Obokata M; Sakamoto Y; Mori S; Tsutsumi M; Nauchi M; Honda Y; Tokuda T; Makino K; Shirai S; Hirano K
    Int J Cardiovasc Imaging; 2018 Oct; 34(10):1521-1528. PubMed ID: 29785558
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Different Neointimal Pattern in Early vs. Late In-Stent Restenosis and Clinical Outcomes After Drug-Coated Balloon Angioplasty - An Optical Coherence Tomography Study.
    Lee JH; Jung HW; Kim JS; Hong SJ; Ahn CM; Kim BK; Ko YG; Choi D; Hong MK; Jang Y
    Circ J; 2018 Oct; 82(11):2745-2752. PubMed ID: 30197402
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.