These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 28148673)

  • 1. Augmenting the osseointegration of endoprostheses using laser-sintered porous collars: an in vivo study.
    Mumith A; Coathup M; Chimutengwende-Gordon M; Aston W; Briggs T; Blunn G
    Bone Joint J; 2017 Feb; 99-B(2):276-282. PubMed ID: 28148673
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of strontium and silicon substituted hydroxyapatite electrochemical coatings on bone ingrowth and osseointegration of selective laser sintered porous metal implants.
    Mumith A; Cheong VS; Fromme P; Coathup MJ; Blunn GW
    PLoS One; 2020; 15(1):e0227232. PubMed ID: 31923253
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hydroxyapatite-coated collars reduce radiolucent line progression in cemented distal femoral bone tumor implants.
    Coathup MJ; Sanghrajka A; Aston WJ; Gikas PD; Pollock RC; Cannon SR; Skinner JA; Briggs TW; Blunn GW
    Clin Orthop Relat Res; 2015 Apr; 473(4):1505-14. PubMed ID: 25634027
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Early radiographic osseointegration of a novel highly porous 3D-printed titanium collar for megaprostheses compared to a previous generation smooth HA-coated collar.
    Haider T; Pagkalos I; Morris G; Parry MC; Jeys LM
    Arch Orthop Trauma Surg; 2023 Aug; 143(8):4671-4677. PubMed ID: 36598605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Osseointegration of porous titanium implants with and without electrochemically deposited DCPD coating in an ovine model.
    Chen D; Bertollo N; Lau A; Taki N; Nishino T; Mishima H; Kawamura H; Walsh WR
    J Orthop Surg Res; 2011 Nov; 6():56. PubMed ID: 22053991
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term survival of cemented distal femoral endoprostheses with a hydroxyapatite-coated collar: a histological study and a radiographic follow-up.
    Coathup MJ; Batta V; Pollock RC; Aston WJ; Cannon SR; Skinner JA; Briggs TW; Unwin PS; Blunn GW
    J Bone Joint Surg Am; 2013 Sep; 95(17):1569-75. PubMed ID: 24005197
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The
    Chimutengwende-Gordon M; Pendegrass C; Blunn G
    Bone Joint J; 2017 Mar; 99-B(3):393-400. PubMed ID: 28249981
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Osteogenic protein-1 delivered by hydroxyapatite-coated implants improves bone ingrowth in extracortical bone bridging.
    Saran N; Zhang R; Turcotte RE
    Clin Orthop Relat Res; 2011 May; 469(5):1470-8. PubMed ID: 20878288
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Early radiological outcomes of a fully porous bridging collar in lower-limb endoprosthetic reconstructions: a case-matched retrospective series to assess osseointegration.
    Stevenson J; Siddiqi MA; Sheehy V; Kendrick B; Whitwell D; Taylor A; Blunn G; Mohammad HR; Kamath AF; Thoma S
    Arthroplasty; 2024 Mar; 6(1):17. PubMed ID: 38429812
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Osseointegration in porous coated knee arthroplasty. The influence of component coating type in sheep.
    Bellemans J
    Acta Orthop Scand Suppl; 1999 Oct; 288():1-35. PubMed ID: 10949554
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Osteointegration of hydroxyapatite-coated collars in cemented massive endoprostheses following revision surgery.
    Davies B; Kaila R; Andritsos L; Gray Stephens C; Blunn GW; Gerrand C; Gikas P; Johnston A
    Bone Jt Open; 2021 Jun; 2(6):371-379. PubMed ID: 34134510
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Osseointegration of multiphase anodic spark deposition treated porous titanium implants in an ovine model.
    Bertollo N; Sandrini E; Dalla Pria P; Walsh WR
    J Arthroplasty; 2015 Mar; 30(3):484-8. PubMed ID: 25540993
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Extracortical bone bridging in tumor endoprostheses. Radiographic and histologic analysis.
    Tanzer M; Turcotte R; Harvey E; Bobyn JD
    J Bone Joint Surg Am; 2003 Dec; 85(12):2365-70. PubMed ID: 14668506
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implants.
    Cheong VS; Fromme P; Mumith A; Coathup MJ; Blunn GW
    J Mech Behav Biomed Mater; 2018 Nov; 87():230-239. PubMed ID: 30086415
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does implantation site influence bone ingrowth into 3D-printed porous implants?
    Walsh WR; Pelletier MH; Wang T; Lovric V; Morberg P; Mobbs RJ
    Spine J; 2019 Nov; 19(11):1885-1898. PubMed ID: 31255790
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Partial Bone Formation in Additive Manufactured Porous Implants Reduces Predicted Stress and Danger of Fatigue Failure.
    Cheong VS; Fromme P; Coathup MJ; Mumith A; Blunn GW
    Ann Biomed Eng; 2020 Jan; 48(1):502-514. PubMed ID: 31549330
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term results of segmental prosthesis fixation by extracortical bone-bridging and ingrowth.
    Chao EY; Fuchs B; Rowland CM; Ilstrup DM; Pritchard DJ; Sim FH
    J Bone Joint Surg Am; 2004 May; 86(5):948-55. PubMed ID: 15118037
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Novel Nanostructured Surface on Titanium Implants Increases Osseointegration in a Sheep Model.
    Jones CF; Quarrington RD; Tsangari H; Starczak Y; Mulaibrahimovic A; Burzava ALS; Christou C; Barker AJ; Morel J; Bright R; Barker D; Brown T; Vasilev K; Anderson PH
    Clin Orthop Relat Res; 2022 Nov; 480(11):2232-2250. PubMed ID: 36001022
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of sol-gel-formed calcium phosphate coatings on bone ingrowth and osteoconductivity of porous-surfaced Ti alloy implants.
    Nguyen HQ; Deporter DA; Pilliar RM; Valiquette N; Yakubovich R
    Biomaterials; 2004 Feb; 25(5):865-76. PubMed ID: 14609675
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of laser sintered Ti-6Al-4V implants with bone-inspired porosity and micro/nanoscale surface roughness in the rabbit femur.
    Cohen DJ; Cheng A; Sahingur K; Clohessy RM; Hopkins LB; Boyan BD; Schwartz Z
    Biomed Mater; 2017 Apr; 12(2):025021. PubMed ID: 28452335
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.