These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 28153367)

  • 1. Using Sigma Quality Control to Verify and Monitor Performance in a Multi-Instrument, Multisite Integrated Health Care Network.
    Harrison HH; Jones JB
    Clin Lab Med; 2017 Mar; 37(1):207-241. PubMed ID: 28153367
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance evaluation of a coagulation laboratory using Sigma metrics.
    Shaikh MS; Ali SA; Rashid A; Karim F; Moiz B
    Int J Health Care Qual Assur; 2018 Jul; 31(6):600-608. PubMed ID: 29954266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Utilizing global data to estimate analytical performance on the Sigma scale: A global comparative analysis of methods, instruments, and manufacturers through external quality assurance and proficiency testing programs.
    Westgard SA
    Clin Biochem; 2016 Jun; 49(9):699-707. PubMed ID: 26948097
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analytical performance evaluation of a high-volume hematology laboratory utilizing sigma metrics as standard of excellence.
    Shaikh MS; Moiz B
    Int J Lab Hematol; 2016 Apr; 38(2):193-7. PubMed ID: 26847366
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quality control validation for a veterinary laboratory network of six Sysmex XT-2000iV hematology analyzers.
    Daly S; Graham PA; Freeman KP
    Vet Clin Pathol; 2022 Dec; 51(4):565-576. PubMed ID: 35922888
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interest and limits of the six sigma methodology in medical laboratory.
    Scherrer F; Bouilloux JP; Calendini O; Chamard D; Cornu F
    Ann Biol Clin (Paris); 2017 Feb; 75(1):107-113. PubMed ID: 28132939
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Applying Sigma Metrics to Reduce Outliers.
    Litten J
    Clin Lab Med; 2017 Mar; 37(1):177-186. PubMed ID: 28153365
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the analytical performance of endocrine analytes using sigma metrics.
    Liu Y; Cao Y; Liu X; Wu L; Cai W
    J Clin Lab Anal; 2021 Jan; 35(1):e23581. PubMed ID: 32951270
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Theoretic and practical contribution of bayesian inference to statistical process control: The experience of the Lyon Hospitals Board hemostasis laboratory].
    Sobas F; Jousselme E; Beghin M; Baillat MG; Perucchetti Y; Nougier C
    Ann Biol Clin (Paris); 2020 Oct; 78(5):574-580. PubMed ID: 32716002
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of Sigma metrics in the quality control strategies of immunology and protein analytes.
    Luo Y; Yan X; Xiao Q; Long Y; Pu J; Li Q; Cai Y; Chen Y; Zhang H; Chen C; Ou S
    J Clin Lab Anal; 2021 Nov; 35(11):e24041. PubMed ID: 34606652
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Practical application of Sigma Metrics QC procedures in clinical chemistry.
    Schoenmakers CH; Naus AJ; Vermeer HJ; van Loon D; Steen G
    Clin Chem Lab Med; 2011 Nov; 49(11):1837-43. PubMed ID: 21801029
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of hematology quality control using six sigma metrics.
    Goel S; Nisal AR; Raj A; Nimbargi RC
    Indian J Pathol Microbiol; 2024 Apr; 67(2):332-335. PubMed ID: 38394423
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.
    Westgard JO
    Clin Lab Med; 2017 Mar; 37(1):137-150. PubMed ID: 28153361
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sigma metrics used to assess analytical quality of clinical chemistry assays: importance of the allowable total error (TEa) target.
    Hens K; Berth M; Armbruster D; Westgard S
    Clin Chem Lab Med; 2014 Jul; 52(7):973-80. PubMed ID: 24615486
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Practical application of European biological variation combined with Westgard Sigma Rules in internal quality control.
    Song Z; Zhang J; Liu B; Wang H; Bi L; Xu Q
    Clin Chem Lab Med; 2022 Oct; 60(11):1729-1735. PubMed ID: 36036501
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluating laboratory key performance using quality indicators in Alexandria University Hospital Clinical Chemistry Laboratories.
    Rizk MM; Zaki A; Hossam N; Aboul-Ela Y
    J Egypt Public Health Assoc; 2014 Dec; 89(3):105-13. PubMed ID: 25534174
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A primer on patient-based quality control techniques.
    Badrick T; Cervinski M; Loh TP
    Clin Biochem; 2019 Feb; 64():1-5. PubMed ID: 30550876
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Timeliness “at a glance”: assessing the turnaround time through the six sigma metrics.
    Ialongo C; Bernardini S
    Biochem Med (Zagreb); 2016; 26(1):98-102. PubMed ID: 27019886
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of Six Sigma Worksheets for assessment of internal and external failure costs associated with candidate quality control rules for an ADVIA 120 hematology analyzer.
    Cian F; Villiers E; Archer J; Pitorri F; Freeman K
    Vet Clin Pathol; 2014 Jun; 43(2):164-71. PubMed ID: 24750485
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative analysis of calculating sigma metrics by a trueness verification proficiency testing-based approach and an internal quality control data inter-laboratory comparison-based approach.
    Li R; Wang T; Gong L; Peng P; Yang S; Zhao H; Xiong P
    J Clin Lab Anal; 2019 Nov; 33(9):e22989. PubMed ID: 31386228
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.