These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 28159450)

  • 1. Laser fabrication of electrical feedthroughs in polymer encapsulations for active implantable medical devices.
    Gough Z; Chaminade C; Barclay-Monteith P; Kallinen A; Lei W; Ganesan R; Grace J; McKenzie DR
    Med Eng Phys; 2017 Apr; 42():105-110. PubMed ID: 28159450
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evolving uses for implantable PEEK and PEEK based compounds.
    Jarman-Smith M
    Med Device Technol; 2008 Oct; 19(6):12-5. PubMed ID: 18988542
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.
    Siskey R; Ciccarelli L; Lui MK; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2428-2440. PubMed ID: 27677290
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface topography and wetting modifications of PEEK for implant applications.
    Akkan CK; Hammadeh ME; May A; Park HW; Abdul-Khaliq H; Strunskus T; Aktas OC
    Lasers Med Sci; 2014 Sep; 29(5):1633-9. PubMed ID: 24691717
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Research Progress of 3D-Printed Polyetheretherketone in Implantable Medical Devices].
    Zhang S
    Zhongguo Yi Liao Qi Xie Za Zhi; 2024 May; 48(3):251-256. PubMed ID: 38863089
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical and in vitro investigation of a porous PEEK foam for medical device implants.
    Landy BC; Vangordon SB; McFetridge PS; Sikavitsas VI; Jarman-Smith M
    J Appl Biomater Funct Mater; 2013 Jun; 11(1):e35-44. PubMed ID: 23413130
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Chip-scale hermetic feedthroughs for implantable bionics.
    Guenther T; Dodds CW; Lovell NH; Suaning GJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():6717-20. PubMed ID: 22255880
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantifying Moisture Penetration in Encapsulated Devices by Heavy Water Mass Spectrometry: A Standard Moisture Leak Using Poly(ether-ether-ketone).
    Lei W; Fong NWS; Jarvis KL; McKenzie DR
    ACS Appl Mater Interfaces; 2021 Mar; 13(11):13666-13675. PubMed ID: 33688725
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fabrication and test of a hermetic miniature implant package with 360 electrical feedthroughs.
    Schuettler M; Ordonez JS; Silva Santisteban T; Schatz A; Wilde J; Stieglitz T
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1585-8. PubMed ID: 21096387
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hermetic diamond capsules for biomedical implants enabled by gold active braze alloys.
    Lichter SG; Escudié MC; Stacey AD; Ganesan K; Fox K; Ahnood A; Apollo NV; Kua DC; Lee AZ; McGowan C; Saunders AL; Burns O; Nayagam DA; Williams RA; Garrett DJ; Meffin H; Prawer S
    Biomaterials; 2015; 53():464-74. PubMed ID: 25890743
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Polyetheretherketone (PEEK). Part I: prospects for use in orthopaedics and traumatology].
    Horák Z; Pokorný D; Fulín P; Slouf M; Jahoda D; Sosna A
    Acta Chir Orthop Traumatol Cech; 2010; 77(6):463-9. PubMed ID: 21223825
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implantable PEEK extends the options.
    Jarman-Smith M
    Med Device Technol; 2006 Sep; 17(7):51-2. PubMed ID: 17039961
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polyetheretherketone for long-term implantable devices.
    Williams D
    Med Device Technol; 2008; 19(1):8, 10-1. PubMed ID: 18348432
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Physicomechanical characterization of polyetheretherketone and current esthetic dental CAD/CAM polymers after aging in different storage media.
    Liebermann A; Wimmer T; Schmidlin PR; Scherer H; Löffler P; Roos M; Stawarczyk B
    J Prosthet Dent; 2016 Mar; 115(3):321-8.e2. PubMed ID: 26548869
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?
    Torstrick FB; Evans NT; Stevens HY; Gall K; Guldberg RE
    Clin Orthop Relat Res; 2016 Nov; 474(11):2373-2383. PubMed ID: 27154533
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis.
    Ferguson SJ; Visser JM; Polikeit A
    Eur Spine J; 2006 Feb; 15(2):149-56. PubMed ID: 15940477
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Polyetheretherketone (PEEK). Part II: application in clinical practice].
    Pokorný D; Fulín P; Slouf M; Jahoda D; Landor I; Sosna A
    Acta Chir Orthop Traumatol Cech; 2010; 77(6):470-8. PubMed ID: 21223826
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Properties and Corrosion Performance of Self-reinforced Composite PEEK for Proposed Use as a Modular Taper Gasket.
    Ouellette ES; Gilbert JL
    Clin Orthop Relat Res; 2016 Nov; 474(11):2414-2427. PubMed ID: 27146655
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polyetheretherketone (PEEK) for medical applications.
    Panayotov IV; Orti V; Cuisinier F; Yachouh J
    J Mater Sci Mater Med; 2016 Jul; 27(7):118. PubMed ID: 27259708
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.
    Baykal D; Siskey RS; Underwood RJ; Briscoe A; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2384-2393. PubMed ID: 27457625
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.