BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 28166055)

  • 1. A comprehensive and efficient daily quality assurance for PBS proton therapy.
    Actis O; Meer D; König S; Weber DC; Mayor A
    Phys Med Biol; 2017 Mar; 62(5):1661-1675. PubMed ID: 28166055
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and long-term stability of a comprehensive daily QA program for a modern pencil beam scanning (PBS) proton therapy delivery system.
    Rana S; Bennouna J; Samuel EJJ; Gutierrez AN
    J Appl Clin Med Phys; 2019 Apr; 20(4):29-44. PubMed ID: 30920146
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A method to reconstruct and apply 3D primary fluence for treatment delivery verification.
    Liu S; Mazur TR; Li H; Curcuru A; Green OL; Sun B; Mutic S; Yang D
    J Appl Clin Med Phys; 2017 Jan; 18(1):128-138. PubMed ID: 28291913
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Technical Note: An efficient daily QA procedure for proton pencil beam scanning.
    Younkin JE; Shen J; Bues M; Robertson DG; Mundy DW; Clouser E; Liu W; Ding X; Stoker JB
    Med Phys; 2018 Mar; 45(3):1040-1049. PubMed ID: 29394447
    [TBL] [Abstract][Full Text] [Related]  

  • 5. AAPM task group 224: Comprehensive proton therapy machine quality assurance.
    Arjomandy B; Taylor P; Ainsley C; Safai S; Sahoo N; Pankuch M; Farr JB; Yong Park S; Klein E; Flanz J; Yorke ED; Followill D; Kase Y
    Med Phys; 2019 Aug; 46(8):e678-e705. PubMed ID: 31125441
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Evaluation of daily quality assurance for proton therapy at National Cancer Center Hospital East.].
    Kohno R; Nishio T; Miyagishi T; Matsumura K; Saito H; Uzawa N; Sasano T; Nakamura T; Ogino T
    Igaku Butsuri; 2006; 26(4):153-62. PubMed ID: 17634734
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Auto-Trending daily quality assurance program for a pencil beam scanning proton system aligned with TG 224.
    Shi C; Chen Q; Yu F; Zhang J; Kang M; Tang S; Chang C; Lin H
    J Appl Clin Med Phys; 2021 Jan; 22(1):117-127. PubMed ID: 33338293
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical Note: Use of commercial multilayer Faraday cup for offline daily beam range verification at the McLaren Proton Therapy Center.
    Tesfamicael B; Athar B; Bejarano Buele A; Kozlyuk V; Nichiporov D; Watts DA; Arjomandy B
    Med Phys; 2019 Feb; 46(2):1049-1053. PubMed ID: 30570757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Daily QA in proton therapy using a single commercially available detector.
    Lambert J; Bäumer C; Koska B; Ding X
    J Appl Clin Med Phys; 2014 Nov; 15(6):5005. PubMed ID: 25493526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A revision of proton machine quality assurance for wobbled-proton-beam therapy.
    Kase Y; Yamashita H; Numano M; Fuji H; Murayama S
    Radiol Phys Technol; 2013 Jul; 6(2):444-52. PubMed ID: 23689901
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel daily QA system for proton therapy.
    Ding X; Zheng Y; Zeidan O; Mascia A; Hsi W; Kang Y; Ramirez E; Schreuder N; Harris B
    J Appl Clin Med Phys; 2013 Mar; 14(2):4058. PubMed ID: 23470936
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom.
    Bizzocchi N; Fracchiolla F; Schwarz M; Algranati C
    Med Dosim; 2017 Autumn; 42(3):238-246. PubMed ID: 28645509
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design of a QA method to characterize submillimeter-sized PBS beam properties using a 2D ionization chamber array.
    Lin Y; Bentefour H; Flanz J; Kooy H; Clasie B
    Phys Med Biol; 2018 May; 63(10):105007. PubMed ID: 29644984
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technical Note: A simple and fast daily quality assurance solution for modulated scanning proton and carbon ion beams.
    Chen JN; Moyers MF; Lin LC
    Med Phys; 2021 Oct; 48(10):5684-5693. PubMed ID: 34370305
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Daily QA of linear accelerators using only EPID and OBI.
    Sun B; Goddu SM; Yaddanapudi S; Noel C; Li H; Cai B; Kavanaugh J; Mutic S
    Med Phys; 2015 Oct; 42(10):5584-94. PubMed ID: 26429233
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impacts of gantry angle dependent scanning beam properties on proton PBS treatment.
    Lin Y; Clasie B; Lu HM; Flanz J; Shen T; Jee KW
    Phys Med Biol; 2017 Jan; 62(2):344-357. PubMed ID: 27997378
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A systematic study of independently-tuned room-specific PBS beam model in a beam-matched multiroom proton therapy system.
    Huang YH; Fang C; Yang T; Cao L; Zhang G; Qu B; Zhang Y; Wang Z; Xu S
    Radiat Oncol; 2021 Oct; 16(1):206. PubMed ID: 34715894
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation.
    Handsfield LL; Jones R; Wilson DD; Siebers JV; Read PW; Chen Q
    Med Phys; 2014 Oct; 41(10):101703. PubMed ID: 25281942
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Daily quality assurance phantom for ultrasound image guided radiation therapy.
    Drever L; Hilts M
    J Appl Clin Med Phys; 2007 Jun; 8(3):126-136. PubMed ID: 17712304
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical Note: Long-term monitoring of diode sensitivity degradation induced by proton irradiation.
    Younkin JE; Robertson DG; Liu W; Hu Y; Morales DH; Bues M; Shen J; Ding X
    Med Phys; 2021 Nov; 48(11):6634-6641. PubMed ID: 34608990
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.