These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 28173979)

  • 41. Feasibility study of patient positioning verification in electron beam radiotherapy with an electronic portal imaging device (EPID).
    Ramm U; Köhn J; Rodriguez Dominguez R; Licher J; Koch N; Kara E; Scherf C; Rödel C; Weiß C
    Phys Med; 2014 Mar; 30(2):215-20. PubMed ID: 23850512
    [TBL] [Abstract][Full Text] [Related]  

  • 42. An EPID-based method to determine mechanical deformations in a linear accelerator.
    Gourdeau D; Gingras L; Beaulieu F; Leclerc G; Archambault L
    Med Phys; 2018 Nov; 45(11):5054-5065. PubMed ID: 30242848
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A field size specific backscatter correction algorithm for accurate EPID dosimetry.
    Berry SL; Polvorosa CS; Wuu CS
    Med Phys; 2010 Jun; 37(6):2425-34. PubMed ID: 20632552
    [TBL] [Abstract][Full Text] [Related]  

  • 44. 3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry.
    Mans A; Remeijer P; Olaciregui-Ruiz I; Wendling M; Sonke JJ; Mijnheer B; van Herk M; Stroom JC
    Radiother Oncol; 2010 Feb; 94(2):181-7. PubMed ID: 20089323
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Time dependent pre-treatment EPID dosimetry for standard and FFF VMAT.
    Podesta M; Nijsten SM; Persoon LC; Scheib SG; Baltes C; Verhaegen F
    Phys Med Biol; 2014 Aug; 59(16):4749-68. PubMed ID: 25088064
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Sensitivity of an Elekta iView GT a-Si EPID model to delivery errors for pre-treatment verification of IMRT fields.
    Herwiningsih S; Hanlon P; Fielding A
    Australas Phys Eng Sci Med; 2014 Dec; 37(4):763-70. PubMed ID: 25182667
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Online 3D EPID-based dose verification: Proof of concept.
    Spreeuw H; Rozendaal R; Olaciregui-Ruiz I; González P; Mans A; Mijnheer B; van Herk M
    Med Phys; 2016 Jul; 43(7):3969. PubMed ID: 27370115
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A global calibration model for a-Si EPIDs used for transit dosimetry.
    Nijsten SM; van Elmpt WJ; Jacobs M; Mijnheer BJ; Dekker AL; Lambin P; Minken AW
    Med Phys; 2007 Oct; 34(10):3872-84. PubMed ID: 17985633
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Inclusion of the treatment couch in portal dose image prediction for high precision EPID dosimetry.
    Ali AS; Dirkx ML; Breuers MG; Heijmen BJ
    Med Phys; 2011 Jan; 38(1):377-81. PubMed ID: 21361205
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A novel technique for VMAT QA with EPID in cine mode on a Varian TrueBeam linac.
    Liu B; Adamson J; Rodrigues A; Zhou F; Yin FF; Wu Q
    Phys Med Biol; 2013 Oct; 58(19):6683-700. PubMed ID: 24018655
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Portal dose image verification: the collapsed cone superposition method applied with different electronic portal imaging devices.
    Dahlgren CV; Eilertsen K; Jørgensen TD; Ahnesjö A
    Phys Med Biol; 2006 Jan; 51(2):335-49. PubMed ID: 16394342
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A new approach in the design of electronic portal imaging devices for portal dosimetry in radiotherapy.
    Badel JN; Partouche-Sebban D; Abraham I; Carrie C
    Phys Med; 2014 Sep; 30(6):644-53. PubMed ID: 24767869
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery.
    Rowshanfarzad P; Sabet M; O'Connor DJ; Greer PB
    Med Phys; 2011 Jul; 38(7):3963-70. PubMed ID: 21858993
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Dose-response characteristics of an amorphous silicon EPID.
    Winkler P; Hefner A; Georg D
    Med Phys; 2005 Oct; 32(10):3095-105. PubMed ID: 16279061
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments.
    Wendling M; McDermott LN; Mans A; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2009 Jul; 36(7):3310-21. PubMed ID: 19673227
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration.
    Sabet M; Rowshanfarzad P; Vial P; Menk FW; Greer PB
    Phys Med Biol; 2012 Aug; 57(15):N295-306. PubMed ID: 22801089
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Site-specific alert criteria to detect patient-related errors with 3D EPID transit dosimetry.
    Olaciregui-Ruiz I; Rozendaal R; Mijnheer B; Mans A
    Med Phys; 2019 Jan; 46(1):45-55. PubMed ID: 30372521
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Model-based prediction of portal dose images during patient treatment.
    Chytyk-Praznik K; VanUytven E; vanBeek TA; Greer PB; McCurdy BM
    Med Phys; 2013 Mar; 40(3):031713. PubMed ID: 23464308
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Comprehensive fluence model for absolute portal dose image prediction.
    Chytyk K; McCurdy BM
    Med Phys; 2009 Apr; 36(4):1389-98. PubMed ID: 19472646
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Dosimetric IMRT verification with a flat-panel EPID.
    Warkentin B; Steciw S; Rathee S; Fallone BG
    Med Phys; 2003 Dec; 30(12):3143-55. PubMed ID: 14713081
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.