These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
104 related articles for article (PubMed ID: 2817478)
1. Desaturation noted by pulmonary artery catheter oximeter after methylene blue injection. Varon AJ; Anderson HB; Civetta JM Anesthesiology; 1989 Nov; 71(5):791-4. PubMed ID: 2817478 [No Abstract] [Full Text] [Related]
2. Effect of methylene blue on the absorbance of solutions of haemoglobin. Gorman ES; Shnider MR Br J Anaesth; 1988 Mar; 60(4):439-44. PubMed ID: 3355740 [TBL] [Abstract][Full Text] [Related]
3. Methylene blue and indocyanine green artifactually lower pulse oximetry readings of oxygen saturation. Studies in dogs. Sidi A; Paulus DA; Rush W; Gravenstein N; Davis RF J Clin Monit; 1987 Oct; 3(4):249-56. PubMed ID: 3681358 [TBL] [Abstract][Full Text] [Related]
4. Interference of methylene blue with CO-Oximetry of hemoglobin derivatives. Gourlain H; Buneaux F; Borron SW; Gouget B; Levillain P Clin Chem; 1997 Jun; 43(6 Pt 1):1078-80. PubMed ID: 9191565 [No Abstract] [Full Text] [Related]
5. False indication of arterial oxygen desaturation and methemoglobinemia following injection of methylene blue in urological surgery. Kirlangitis JJ; Middaugh RE; Zablocki A; Rodriquez F Mil Med; 1990 Jun; 155(6):260-2. PubMed ID: 2122301 [TBL] [Abstract][Full Text] [Related]
6. Cerebral oximetry changes "out of the blue". Yu JS; Seefelder C Paediatr Anaesth; 2020 May; 30(5):626-627. PubMed ID: 32243671 [No Abstract] [Full Text] [Related]
7. Estimation of oxygen utilization by dual oximetry. Räsänen J; Downs JB; Malec DJ; DeHaven B; Seidman P Ann Surg; 1987 Nov; 206(5):621-3. PubMed ID: 3314749 [TBL] [Abstract][Full Text] [Related]
8. Somanetics INVOS 3100 cerebral oximeter. Dujovny M; Ausman JI; Stoddart H; Slavin KV; Lewis GD; Widman R Neurosurgery; 1995 Jul; 37(1):160. PubMed ID: 8587681 [No Abstract] [Full Text] [Related]
9. Correct and spurious calibration of the Oxicom oximeter. Russell EL Cathet Cardiovasc Diagn; 1994 Nov; 33(3):264-6. PubMed ID: 7874723 [TBL] [Abstract][Full Text] [Related]
10. Accuracy of oxyhemoglobin saturation monitors during simulated altitude exposure of men with chronic obstructive pulmonary disease. Mehm WJ; Dillard TA; Berg BW; Dooley JW; Rajagopal KR Aviat Space Environ Med; 1991 May; 62(5):418-21. PubMed ID: 2053906 [TBL] [Abstract][Full Text] [Related]
11. Methylene blue and pulse oximeter readings in a patient undergoing transurethral procedure. Schleifer WF; Chapin JW; Cuka DJ; Taylor RJ Urology; 1990 Dec; 36(6):537-8. PubMed ID: 2247925 [No Abstract] [Full Text] [Related]
12. Carboxyhaemoglobinaemia and pulse oximetry. Vegfors M; Lennmarken C Br J Anaesth; 1991 May; 66(5):625-6. PubMed ID: 2031826 [TBL] [Abstract][Full Text] [Related]
14. In vitro oxyhaemoglobin saturation measurements in haemoglobin solutions using fibreoptic pulmonary artery catheters. Kong CS; Ryder IG; Kahn R; Gregory L; Mackenzie CF Br J Anaesth; 1995 Feb; 74(2):201-8. PubMed ID: 7696072 [TBL] [Abstract][Full Text] [Related]
15. [Medico-legal application of hemoglobin analysis using CO-oximeter]. Watanabe N Hokkaido Igaku Zasshi; 2003 Nov; 78(6):557-66. PubMed ID: 14672043 [No Abstract] [Full Text] [Related]
16. Effect on oximetry of dyes used for sentinel lymph node biopsy. Piñero A; Illana J; García-Palenciano C; Cañizarese F; Canteras M; Cañadillas V; Durán E; Parilla P Arch Surg; 2004 Nov; 139(11):1204-7. PubMed ID: 15546820 [TBL] [Abstract][Full Text] [Related]
17. Severe oxyhemoglobin desaturation during induction of anesthesia in a patient with congenital methemoglobinemia. Baraka AS; Ayoub CM; Kaddoum RN; Maalouli JM; Chehab IR; Hadi UM Anesthesiology; 2001 Nov; 95(5):1296-7. PubMed ID: 11685006 [No Abstract] [Full Text] [Related]
19. Effect of methylene blue on the vasodilator action of inhaled nitric oxide in hypoxic sheep. Young JD; Dyar OJ; Xiong L; Zhang J; Gavaghan D Br J Anaesth; 1994 Oct; 73(4):511-6. PubMed ID: 7999494 [TBL] [Abstract][Full Text] [Related]