These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 28181156)

  • 41. The reproducibility and prognostic value of serial measurements of heart rate response to regadenoson during myocardial perfusion imaging.
    Andrikopoulou E; AlJaroudi WA; Farag A; Lester D; Patel H; Iskandrian AE; Hage FG
    Eur J Nucl Med Mol Imaging; 2016 Jul; 43(8):1493-502. PubMed ID: 27079736
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The significance of automatically measured transient ischemic dilation in identifying severe and extensive coronary artery disease in regadenoson, single-isotope technetium-99m myocardial perfusion SPECT.
    Golzar Y; Olusanya A; Pe N; Dua SG; Golzar J; Gidea C; Doukky R
    J Nucl Cardiol; 2015 Jun; 22(3):526-34. PubMed ID: 25824022
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Impaired coronary flow reserve is the most important marker of viable myocardium in the myocardial segment-based analysis of dual-isotope gated myocardial perfusion single-photon emission computed tomography.
    Lee WW; So Y; Kim KB; Lee DS
    Korean J Radiol; 2014; 15(2):277-85. PubMed ID: 24642696
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparison of the prognostic value of regadenoson and adenosine myocardial perfusion imaging.
    Farzaneh-Far A; Shaw LK; Dunning A; Oldan JD; O'Connor CM; Borges-Neto S
    J Nucl Cardiol; 2015 Aug; 22(4):600-7. PubMed ID: 25987234
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Usefulness of stress gated technetium-99m single photon emission computed tomographic myocardial perfusion imaging for the prediction of cardiac death in patients with moderate to severe left ventricular systolic dysfunction and suspected coronary artery disease.
    Ahlberg AW; Kazi FA; Azemi T; Katten DM; O'Sullivan DM; Papaioannou GI; Danias PG; Heller GV
    Am J Cardiol; 2012 Jan; 109(1):26-30. PubMed ID: 21943938
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Randomized Comparison of Clinical Effectiveness of Pharmacologic SPECT and PET MPI in Symptomatic CAD Patients.
    Patel KK; Al Badarin F; Chan PS; Spertus JA; Courter S; Kennedy KF; Case JA; McGhie AI; Heller GV; Bateman TM
    JACC Cardiovasc Imaging; 2019 Sep; 12(9):1821-1831. PubMed ID: 31326480
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging.
    Liu CJ; Wu YW; Ko KY; Chen YC; Cheng MF; Yen RF; Tzen KY
    PLoS One; 2015; 10(7):e0134485. PubMed ID: 26230651
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The impacts of severe perfusion defects, akinetic/dyskinetic segments, and viable myocardium on the accuracy of volumes and LVEF measured by gated ⁹⁹mTc-MIBI SPECT and gated ¹⁸F-FDG PET in patients with left ventricular aneurysm: cardiac magnetic resonance imaging as the reference.
    Wei H; Tian C; Schindler TH; Qiu M; Lu M; Shen R; Tian Y; Zhao SH; Zhang X
    J Nucl Cardiol; 2014 Dec; 21(6):1230-44. PubMed ID: 25189143
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Initial experience with regadenoson stress positron emission tomography in patients with left bundle branch block: Low prevalence of septal defects and high accuracy for obstructive coronary artery disease.
    Meredith D; Cremer PC; Harb SC; Xu B; Mentias A; Jaber WA
    J Nucl Cardiol; 2021 Apr; 28(2):536-542. PubMed ID: 30877551
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Single-photon emission computed tomography myocardial perfusion imaging and the risk of sudden cardiac death in patients with coronary disease and left ventricular ejection fraction>35%.
    Piccini JP; Starr AZ; Horton JR; Shaw LK; Lee KL; Al-Khatib SM; Iskandrian AE; O'Connor CM; Borges-Neto S
    J Am Coll Cardiol; 2010 Jul; 56(3):206-14. PubMed ID: 20620740
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Regadenoson provides perfusion results comparable to adenosine in heterogeneous patient populations: a quantitative analysis from the ADVANCE MPI trials.
    Mahmarian JJ; Peterson LE; Xu J; Cerqueira MD; Iskandrian AE; Bateman TM; Thomas GS; Nabi F
    J Nucl Cardiol; 2015 Apr; 22(2):248-61. PubMed ID: 25287737
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Left ventricular function in response to dipyridamole stress: head-to-head comparison between
    Giorgi MC; Meneghetti JC; Soares J; Izaki M; Falcão A; Imada R; Chalela W; de Oliveira MA; Nomura C; Verberne HJ
    Eur J Nucl Med Mol Imaging; 2017 May; 44(5):876-885. PubMed ID: 27987028
    [TBL] [Abstract][Full Text] [Related]  

  • 53. High-dose dipyridamole and gated sestamibi SPECT imaging provide diagnostic resting and stress ejection fractions useful for predicting extent of coronary artery disease.
    Fleming RM
    Angiology; 2002; 53(4):415-21. PubMed ID: 12143946
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Impact of Positron Emission Tomographic Myocardial Perfusion Imaging on Patient Selection for Revascularization.
    Patel KK; McGhie AI; Kennedy KF; Thompson RC; Spertus JA; Sperry BW; Shaw LJ; Bateman TM
    J Am Coll Cardiol; 2023 Oct; 82(17):1662-1672. PubMed ID: 37852696
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Influence of respiratory motion correction on quantification of myocardial perfusion SPECT.
    Bitarafan-Rajabi A; Rajabi H; Rastgou F; Firoozabady H; Yaghoobi N; Malek H; Langesteger W; Beheshti M
    J Nucl Cardiol; 2015 Oct; 22(5):1019-30. PubMed ID: 25515421
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The prognostic utility of regadenoson SPECT myocardial perfusion imaging in patients with end-stage renal disease: The largest cohort to date.
    Kolkailah AA; Iskander M; Iskander F; Patel PP; Khan R; Doukky R
    J Nucl Cardiol; 2022 Feb; 29(1):101-110. PubMed ID: 32632913
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Detection of post-exercise stunning by early gated SPECT myocardial perfusion imaging: results from the IAEA multi-center study.
    Mut F; Giubbini R; Vitola J; Lusa L; Sobic-Saranovic D; Peix A; Bertagna F; Hang Bui D; Cunha C; Obaldo J; Rodella C; Camoni L; Paez D; Dondi M
    J Nucl Cardiol; 2014 Dec; 21(6):1168-76. PubMed ID: 25213203
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Comparison of dual-source 64-slice adenosine stress CT perfusion with stress-gated SPECT-MPI for evaluation of left ventricular function and volumes.
    Uthamalingam S; Gurm GS; Sidhu MS; Verdini DJ; Vorasettakarnkij Y; Engel LC; Blankstein R; Mamuya WS; Hoffman U; Brady TJ; Cury RC; Ghoshhajra BB
    J Cardiovasc Comput Tomogr; 2012; 6(1):24-30. PubMed ID: 22222164
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Left ventricular dyssynchrony assessed by gated SPECT phase analysis is an independent predictor of death in patients with advanced coronary artery disease and reduced left ventricular function not undergoing cardiac resynchronization therapy.
    Uebleis C; Hellweger S; Laubender RP; Becker A; Sohn HY; Lehner S; Haug A; Bartenstein P; Cumming P; Van Kriekinge SD; Slomka PJ; Hacker M
    Eur J Nucl Med Mol Imaging; 2012 Oct; 39(10):1561-9. PubMed ID: 22752450
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Myocardial perfusion, function, and dyssynchrony in patients with heart failure: baseline results from the single-photon emission computed tomography imaging ancillary study of the Heart Failure and A Controlled Trial Investigating Outcomes of Exercise TraiNing (HF-ACTION) Trial.
    Atchley AE; Kitzman DW; Whellan DJ; Iskandrian AE; Ellis SJ; Pagnanelli RA; Kao A; Abdul-Nour K; O'Connor CM; Ewald G; Kraus WE; Borges-Neto S;
    Am Heart J; 2009 Oct; 158(4 Suppl):S53-63. PubMed ID: 19782789
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.