These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 28184151)

  • 1. Wound and surface temperatures in vivo in torsional and longitudinal modalities of ultrasound in coaxial microincisional cataract surgery.
    Nair S; Nair RU
    Clin Ophthalmol; 2017; 11():249-255. PubMed ID: 28184151
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wound temperature profiles of coaxial mini-incision versus sleeveless microincision phacoemulsification.
    Belkin A; Abulafia A; Michaeli A; Ofir S; Assia EI
    Clin Exp Ophthalmol; 2017 Apr; 45(3):247-253. PubMed ID: 27731924
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Impact of Reused Phaco Tip on Outcomes of Phacoemulsification Surgery.
    Demircan S; Gokce G; Atas M; Baskan B; Goktas E; Zararsiz G
    Curr Eye Res; 2016 May; 41(5):636-42. PubMed ID: 25880893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of Balanced Torsional Phacoemulsification Tip for Cataract Surgery.
    Sabur H; Eroglu SA; Azarsiz SS
    J Curr Ophthalmol; 2022; 34(1):74-79. PubMed ID: 35620374
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of two different ultrasound methods of phacoemulsification.
    Helvacioglu F; Yeter C; Sencan S; Tunc Z; Uyar OM
    Am J Ophthalmol; 2014 Aug; 158(2):221-226.e1. PubMed ID: 24792106
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of 45-degree Kelman and 45-degree balanced phaco tip designs in torsional microcoaxial phacoemulsification.
    Demircan S; Ataş M; Göktaş E; Başkan B
    Int J Ophthalmol; 2015; 8(6):1168-72. PubMed ID: 26682167
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Laboratory assessment of thermal characteristics of three phacoemulsification tip designs operated using torsional ultrasound.
    Zacharias J
    Clin Ophthalmol; 2016; 10():1095-101. PubMed ID: 27358554
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thermal study of longitudinal and torsional ultrasound phacoemulsification: tracking the temperature of the corneal surface, incision, and handpiece.
    Jun B; Berdahl JP; Kim T
    J Cataract Refract Surg; 2010 May; 36(5):832-7. PubMed ID: 20457377
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mini-flared Kelman tip, reverse tip, and sidewinder tip with torsional phaco: a prospective randomized comparative study.
    Hida WT; Tzelikis PF; Nakano CT; Motta AF; Alves MR
    Arq Bras Oftalmol; 2015; 78(1):19-22. PubMed ID: 25714532
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thermal characterization of phacoemulsification probes operated in axial and torsional modes.
    Zacharias J
    J Cataract Refract Surg; 2015 Jan; 41(1):208-16. PubMed ID: 25532644
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of torsional and longitudinal modes using phacoemulsification parameters.
    Rekas M; Montés-Micó R; Krix-Jachym K; Kluś A; Stankiewicz A; Ferrer-Blasco T
    J Cataract Refract Surg; 2009 Oct; 35(10):1719-24. PubMed ID: 19781466
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corneal wound architecture and integrity after torsional and mixed phacoemulsification: evaluation of standard and microincisional coaxial techniques.
    Jun B; Berdahl JP; Kuo AN; Cummings TJ; Kim T
    Ophthalmic Surg Lasers Imaging; 2010; 41(1):128-34. PubMed ID: 20128583
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Heat production: Longitudinal versus torsional phacoemulsification.
    Han YK; Miller KM
    J Cataract Refract Surg; 2009 Oct; 35(10):1799-805. PubMed ID: 19781477
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determining optimal torsional ultrasound power for cataract surgery with automatic longitudinal pulses at maximum vacuum ex vivo.
    Ronquillo CC; Zaugg B; Stagg B; Kirk KR; Gupta I; Barlow WR; Pettey JH; Olson RJ
    Am J Ophthalmol; 2014 Dec; 158(6):1262-1266.e2. PubMed ID: 25174892
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combined occlusion-triggered longitudinal and torsional phacoemulsification during coaxial microincision cataract surgery: effect on 30-degree mini-flared tip behavior.
    Ratnarajan G; Packard R; Ward M
    J Cataract Refract Surg; 2011 May; 37(5):825-9. PubMed ID: 21440411
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of bimanual and micro-coaxial phacoemulsification with torsional ultrasound.
    Wang Y; Xia Y; Liu X; Zheng D; Luo L; Liu Y
    Acta Ophthalmol; 2012 Mar; 90(2):184-7. PubMed ID: 20163365
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve.
    Yoo A; Nam KY; Tchah H; Kim MJ
    PLoS One; 2016; 11(8):e0159049. PubMed ID: 27487206
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Influence of 3.0 mm incision coaxial phacoemulsification and microincision cataract surgery (MICS) on corneal thickness].
    Wylegała E; Rebkowska-Juraszek M; Dobrowolski D; Woyna-Orlewicz A
    Klin Oczna; 2009; 111(7-9):207-11. PubMed ID: 19899575
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of IOP based infusion system with and without balanced phaco tip on cumulative dissipated energy and estimated fluid usage in comparison to gravity fed infusion in torsional phacoemulsification.
    Malik PK; Dewan T; Patidar AK; Sain E
    Eye Vis (Lond); 2017; 4():22. PubMed ID: 28932753
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Consecutive drilling combined with phaco chop for full thickness segmentation of very hard nucleus in coaxial microincisional cataract surgery.
    Chen D; Tang Q; Yu F; Cai X; Lu F
    BMC Ophthalmol; 2019 Jan; 19(1):20. PubMed ID: 30651088
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.