These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Prospective study of filtering blebs after XEN45 surgery. Olate-Pérez Á; Pérez-Torregrosa VT; Gargallo-Benedicto A; Neira-Ibáñez P; Cerdà-Ibáñez M; Osorio-Alayo V; Barreiro-Rego A; Duch-Samper A Arch Soc Esp Oftalmol; 2017 Aug; 92(8):366-371. PubMed ID: 28454898 [TBL] [Abstract][Full Text] [Related]
3. Qualitative and quantitative analysis of filtering blebs with optical coherence tomography. Napoli PE; Zucca I; Fossarello M Can J Ophthalmol; 2014 Apr; 49(2):210-6. PubMed ID: 24767231 [TBL] [Abstract][Full Text] [Related]
4. Quantification of the filtering bleb's structure with anterior segment optical coherence tomography. Kokubun T; Kunikata H; Tsuda S; Himori N; Maruyama K; Nakazawa T Clin Exp Ophthalmol; 2016 Aug; 44(6):446-54. PubMed ID: 27452223 [TBL] [Abstract][Full Text] [Related]
5. Evaluating subconjunctival bleb function after trabeculectomy using slit-lamp optical coherence tomography and ultrasound biomicroscopy. Zhang Y; Wu Q; Zhang M; Song BW; DU XH; Lu B Chin Med J (Engl); 2008 Jul; 121(14):1274-9. PubMed ID: 18713546 [TBL] [Abstract][Full Text] [Related]
6. Filtering bleb evaluation with slit-lamp-adapted 1310-nm optical coherence tomography. Müller M; Hoerauf H; Geerling G; Pape S; Winter C; Hüttmann G; Birngruber R; Laqua H Curr Eye Res; 2006 Nov; 31(11):909-15. PubMed ID: 17114116 [TBL] [Abstract][Full Text] [Related]
7. Structural imaging of conjunctival filtering blebs in XEN gel implantation and trabeculectomy: a confocal and anterior segment optical coherence tomography study. Sacchi M; Agnifili L; Brescia L; Oddone F; Villani E; Nucci P; Mastropasqua L Graefes Arch Clin Exp Ophthalmol; 2020 Aug; 258(8):1763-1770. PubMed ID: 32415535 [TBL] [Abstract][Full Text] [Related]
8. Noninvasive evaluation of phase retardation in blebs after glaucoma surgery using anterior segment polarization-sensitive optical coherence tomography. Fukuda S; Beheregaray S; Kasaragod D; Hoshi S; Kishino G; Ishii K; Yasuno Y; Oshika T Invest Ophthalmol Vis Sci; 2014 Jul; 55(8):5200-6. PubMed ID: 25074775 [TBL] [Abstract][Full Text] [Related]
9. Imaging of trabeculectomy blebs using anterior segment optical coherence tomography. Singh M; Chew PT; Friedman DS; Nolan WP; See JL; Smith SD; Zheng C; Foster PJ; Aung T Ophthalmology; 2007 Jan; 114(1):47-53. PubMed ID: 17070581 [TBL] [Abstract][Full Text] [Related]
10. [Evaluation of the bleb morphology and the function of post filtration surgery using slit-lamp adapted optical coherence tomography and ultrasound biomicroscopy in glaucoma patients]. Wu Q; Zhang Y; Song BW; Lu B; Guan JH Zhonghua Yan Ke Za Zhi; 2008 May; 44(5):402-7. PubMed ID: 18953893 [TBL] [Abstract][Full Text] [Related]
11. Filtering bleb functionality: a clinical, anterior segment optical coherence tomography and in vivo confocal microscopy study. Ciancaglini M; Carpineto P; Agnifili L; Nubile M; Lanzini M; Fasanella V; Mastropasqua L J Glaucoma; 2008; 17(4):308-17. PubMed ID: 18552617 [TBL] [Abstract][Full Text] [Related]
12. Characteristics of successful filtering blebs at 1 year after trabeculectomy using swept-source three-dimensional anterior segment optical coherence tomography. Narita A; Morizane Y; Miyake T; Seguchi J; Baba T; Shiraga F Jpn J Ophthalmol; 2017 May; 61(3):253-259. PubMed ID: 28197740 [TBL] [Abstract][Full Text] [Related]
13. Morphological analysis of functional filtering blebs with anterior segment optical coherence tomography: A short-term prediction for success of trabeculectomy. Raj A; Bahadur H Eur J Ophthalmol; 2021 Jul; 31(4):1978-1985. PubMed ID: 32423253 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of Filtering Bleb Function after Trabeculectomy with Mitomycin C Using Biomicroscopy, Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy. Güven Yılmaz S; Değirmenci C; Palamar M; Yağcı A Turk J Ophthalmol; 2015 Aug; 45(4):132-137. PubMed ID: 27800219 [TBL] [Abstract][Full Text] [Related]
16. Three-dimensional anterior segment optical coherence tomography of filtering blebs after trabeculectomy. Miura M; Kawana K; Iwasaki T; Kiuchi T; Oshika T; Mori H; Yamanari M; Makita S; Yatagai T; Yasuno Y J Glaucoma; 2008; 17(3):193-6. PubMed ID: 18414104 [TBL] [Abstract][Full Text] [Related]
17. Usefulness of Polarization-sensitive Optical Coherence Tomography-derived Attenuation-coefficient Images to Visualize the Internal Structure of the Filtering Bleb. Kosugi M; Kokubun T; Tsuda S; Yamanari M; Nakazawa T Curr Eye Res; 2021 Apr; 46(4):606-609. PubMed ID: 33016140 [TBL] [Abstract][Full Text] [Related]
18. Stratus optical coherence tomography study of filtering blebs after primary trabeculectomy with a fornix-based conjunctival flap. Hirooka K; Takagishi M; Baba T; Takenaka H; Shiraga F Acta Ophthalmol; 2010 Feb; 88(1):60-4. PubMed ID: 19021595 [TBL] [Abstract][Full Text] [Related]
19. Anterior-segment optical coherence tomography of filtering blebs in the early postoperative period of ab externo SIBS microshunt implantation with mitomycin C: Morphological analysis and correlation with intraocular pressure reduction. Ibarz Barberá M; Morales Fernández L; Tañá Rivero P; Gómez de Liaño R; Teus MA Acta Ophthalmol; 2022 Feb; 100(1):e192-e203. PubMed ID: 33838021 [TBL] [Abstract][Full Text] [Related]