These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
475 related articles for article (PubMed ID: 28188408)
1. Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter. Lamia B; Kim HK; Severyn DA; Pinsky MR J Clin Monit Comput; 2018 Feb; 32(1):33-43. PubMed ID: 28188408 [TBL] [Abstract][Full Text] [Related]
2. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Hadian M; Kim HK; Severyn DA; Pinsky MR Crit Care; 2010; 14(6):R212. PubMed ID: 21092290 [TBL] [Abstract][Full Text] [Related]
3. Reliability of cardiac output measurements using LiDCOrapid™ and FloTrac/Vigileo™ across broad ranges of cardiac output values. Asamoto M; Orii R; Otsuji M; Bougaki M; Imai Y; Yamada Y J Clin Monit Comput; 2017 Aug; 31(4):709-716. PubMed ID: 27300325 [TBL] [Abstract][Full Text] [Related]
4. Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference. Mukkamala R; Kohl BA; Mahajan A BMC Anesthesiol; 2021 Jul; 21(1):189. PubMed ID: 34246222 [TBL] [Abstract][Full Text] [Related]
5. Accuracy of Continuous Cardiac Output Measurement With the LiDCOplus System During Intra-Aortic Counterpulsation After Cardiac Surgery. Menger J; Mora B; Skhirtladze K; Fischer A; Jan Ankersmit H; Dworschak M J Cardiothorac Vasc Anesth; 2016 Jun; 30(3):592-8. PubMed ID: 26718662 [TBL] [Abstract][Full Text] [Related]
6. The influence of acute pulmonary hypertension on cardiac output measurements: calibrated pulse contour analysis, transpulmonary and pulmonary artery thermodilution against a modified Fick method in an animal model. Kutter APN; Mosing M; Hartnack S; Raszplewicz J; Renggli M; Mauch JY; Hofer CK Anesth Analg; 2015 Jul; 121(1):99-107. PubMed ID: 25742632 [TBL] [Abstract][Full Text] [Related]
7. Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre. Cho YJ; Koo CH; Kim TK; Hong DM; Jeon Y J Clin Monit Comput; 2016 Dec; 30(6):771-782. PubMed ID: 26429135 [TBL] [Abstract][Full Text] [Related]
8. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method. Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321 [TBL] [Abstract][Full Text] [Related]
9. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients. Wagner JY; Körner A; Schulte-Uentrop L; Kubik M; Reichenspurner H; Kluge S; Reuter DA; Saugel B J Clin Monit Comput; 2018 Apr; 32(2):235-244. PubMed ID: 28540614 [TBL] [Abstract][Full Text] [Related]
10. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Cannesson M; Attof Y; Rosamel P; Joseph P; Bastien O; Lehot JJ Eur J Anaesthesiol; 2007 Oct; 24(10):832-9. PubMed ID: 17666154 [TBL] [Abstract][Full Text] [Related]
11. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Marqué S; Cariou A; Chiche JD; Squara P Crit Care; 2009; 13(3):R73. PubMed ID: 19454009 [TBL] [Abstract][Full Text] [Related]
12. Pulmonary arterial thermodilution, femoral arterial thermodilution and bioreactance cardiac output monitoring in a pediatric hemorrhagic hypovolemic shock model. Ballestero Y; Urbano J; López-Herce J; Solana MJ; Botrán M; Vinciguerra D; Bellón JM Resuscitation; 2012 Jan; 83(1):125-9. PubMed ID: 21763249 [TBL] [Abstract][Full Text] [Related]
13. Comparing the Mutual Interchangeability of ECOM, FloTrac/Vigileo, 3D-TEE, and ITD-PAC Cardiac Output Measuring Systems in Coronary Artery Bypass Grafting. Milam AJ; Ghoddoussi F; Lucaj J; Narreddy S; Kumar N; Reddy V; Hakim J; Krishnan SH J Cardiothorac Vasc Anesth; 2021 Feb; 35(2):514-529. PubMed ID: 32622708 [TBL] [Abstract][Full Text] [Related]
14. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery. Breukers RM; Sepehrkhouy S; Spiegelenberg SR; Groeneveld AB J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265 [TBL] [Abstract][Full Text] [Related]
15. Minimally invasive or noninvasive cardiac output measurement: an update. Sangkum L; Liu GL; Yu L; Yan H; Kaye AD; Liu H J Anesth; 2016 Jun; 30(3):461-80. PubMed ID: 26961819 [TBL] [Abstract][Full Text] [Related]
16. Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution. Lee M; Weinberg L; Pearce B; Scurrah N; Story DA; Pillai P; McCall PR; P McNicol L; Peyton PJ J Clin Monit Comput; 2017 Apr; 31(2):343-351. PubMed ID: 26884378 [TBL] [Abstract][Full Text] [Related]
17. Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers. Squara P; Rotcajg D; Denjean D; Estagnasie P; Brusset A Crit Care; 2009; 13(4):R125. PubMed ID: 19638227 [TBL] [Abstract][Full Text] [Related]
18. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. Manecke GR; Auger WR J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):3-7. PubMed ID: 17289472 [TBL] [Abstract][Full Text] [Related]