408 related articles for article (PubMed ID: 28189541)
21. LC-MS/MS bioanalysis of loratadine (Claritin) in dried blood spot (DBS) samples collected by subjects in a clinical research study.
Li W; Doherty J; Moench P; Flarakos J; Tse FL
J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Mar; 983-984():117-24. PubMed ID: 25645810
[TBL] [Abstract][Full Text] [Related]
22. Multiplexed steroid profiling of gluco- and mineralocorticoids pathways using a liquid chromatography tandem mass spectrometry method.
Travers S; Martinerie L; Bouvattier C; Boileau P; Lombès M; Pussard E
J Steroid Biochem Mol Biol; 2017 Jan; 165(Pt B):202-211. PubMed ID: 27339652
[TBL] [Abstract][Full Text] [Related]
23. Volumetric absorptive microsampling as an alternative sampling strategy for the determination of paracetamol in blood and cerebrospinal fluid.
Delahaye L; Dhont E; De Cock P; De Paepe P; Stove CP
Anal Bioanal Chem; 2019 Jan; 411(1):181-191. PubMed ID: 30353218
[TBL] [Abstract][Full Text] [Related]
24. Volumetric absorptive microsampling as an alternative tool for therapeutic drug monitoring of first-generation anti-epileptic drugs.
Velghe S; Stove CP
Anal Bioanal Chem; 2018 Mar; 410(9):2331-2341. PubMed ID: 29362853
[TBL] [Abstract][Full Text] [Related]
25. Quantitative bioanalysis of paracetamol in rats using volumetric absorptive microsampling (VAMS).
Denniff P; Parry S; Dopson W; Spooner N
J Pharm Biomed Anal; 2015 Apr; 108():61-9. PubMed ID: 25710904
[TBL] [Abstract][Full Text] [Related]
26. Dried haematic microsamples and LC-MS/MS for the analysis of natural and synthetic cannabinoids.
Protti M; Rudge J; Sberna AE; Gerra G; Mercolini L
J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Feb; 1044-1045():77-86. PubMed ID: 28088044
[TBL] [Abstract][Full Text] [Related]
27. Application of a new volumetric microsampling device for quantitative bioanalysis of immunosuppression.
Leino AD; Takyi-Williams J; Wen B; Sun D; Pai MP
Bioanalysis; 2022 Sep; 14(17):1141-1152. PubMed ID: 36208082
[No Abstract] [Full Text] [Related]
28. LC-MS/MS measurement of endogenous steroid hormones and phase II metabolites in blood volumetric absorptive microsampling (VAMS) for doping control purposes.
Ponzetto F; Parasiliti-Caprino M; Leoni L; Marinelli L; Nonnato A; Nicoli R; Kuuranne T; Ghigo E; Mengozzi G; Settanni F
Clin Chim Acta; 2024 Apr; 557():117890. PubMed ID: 38537673
[TBL] [Abstract][Full Text] [Related]
29. Volumetric absorptive MicroSampling vs. other blood sampling materials in LC-MS-based protein analysis - preliminary investigations.
Andersen IKL; Rosting C; Gjelstad A; Halvorsen TG
J Pharm Biomed Anal; 2018 Jul; 156():239-246. PubMed ID: 29729637
[TBL] [Abstract][Full Text] [Related]
30. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.
Bruschettini M; Barco S; Romantsik O; Risso F; Gennai I; Chinea B; Ramenghi LA; Tripodi G; Cangemi G
Bioanalysis; 2016 Sep; 8(18):1893-902. PubMed ID: 27532249
[TBL] [Abstract][Full Text] [Related]
31. Dried Blood Spot Multiplexed Steroid Profiling Using Liquid Chromatography Tandem Mass Spectrometry in Korean Neonates.
Choi R; Park HD; Oh HJ; Lee K; Song J; Lee SY
Ann Lab Med; 2019 May; 39(3):263-270. PubMed ID: 30623618
[TBL] [Abstract][Full Text] [Related]
32. Development, validation, and application of a quantitative volumetric absorptive microsampling-based method in finger prick blood by means of LC-HRMS/MS applicable for adherence monitoring of antipsychotics.
Jacobs CM; Wagmann L; Meyer MR
Anal Bioanal Chem; 2021 Mar; 413(6):1729-1737. PubMed ID: 33517479
[TBL] [Abstract][Full Text] [Related]
33. Drug monitoring by volumetric absorptive microsampling: method development considerations to mitigate hematocrit effects.
Fang K; Bowen CL; Kellie JF; Karlinsey MZ; Evans CA
Bioanalysis; 2018 Feb; 10(4):241-255. PubMed ID: 29333871
[TBL] [Abstract][Full Text] [Related]
34. A volumetric absorptive microsampling LC-MS/MS method for five immunosuppressants and their hematocrit effects.
Koster RA; Niemeijer P; Veenhof H; Hateren KV; Alffenaar JC; Touw DJ
Bioanalysis; 2019 Mar; 11(6):495-508. PubMed ID: 30892068
[No Abstract] [Full Text] [Related]
35. Volumetric Absorptive Microsampling (VAMS) for Targeted LC-MS/MS Determination of Tryptophan-Related Biomarkers.
Protti M; Cirrincione M; Mandrioli R; Rudge J; Regazzoni L; Valsecchi V; Volpi C; Mercolini L
Molecules; 2022 Sep; 27(17):. PubMed ID: 36080419
[TBL] [Abstract][Full Text] [Related]
36. Hematocrit prediction in volumetric absorptive microsamples.
Capiau S; Stove C
J Pharm Biomed Anal; 2020 Oct; 190():113491. PubMed ID: 32777731
[TBL] [Abstract][Full Text] [Related]
37. Measurement of steroids in rats after exposure to an endocrine disruptor: mass spectrometry and radioimmunoassay demonstrate similar results.
Riffle BW; Henderson WM; Laws SC
J Pharmacol Toxicol Methods; 2013; 68(3):314-22. PubMed ID: 23871967
[TBL] [Abstract][Full Text] [Related]
38. Volumetric absorptive microsampling (VAMS®) in therapeutic protein quantification by LC-MS/MS: Investigation of anticoagulant impact on assay performance and recommendations for best practices in method development.
Gao X; Chen C; Geng D; Bateman KP; Shi S; Woolf EJ; Xu Y
J Pharm Biomed Anal; 2021 Mar; 196():113895. PubMed ID: 33486450
[TBL] [Abstract][Full Text] [Related]
39. Determination of oxycodone and its major metabolites in haematic and urinary matrices: Comparison of traditional and miniaturised sampling approaches.
Protti M; Catapano MC; Samolsky Dekel BG; Rudge J; Gerra G; Somaini L; Mandrioli R; Mercolini L
J Pharm Biomed Anal; 2018 Apr; 152():204-214. PubMed ID: 29414014
[TBL] [Abstract][Full Text] [Related]
40. Evaluation of sample extraction methods for minimizing hematocrit effect on whole blood analysis with volumetric absorptive microsampling.
Ye Z; Gao H
Bioanalysis; 2017 Feb; 9(4):349-357. PubMed ID: 28102694
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]