BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

408 related articles for article (PubMed ID: 28189541)

  • 21. LC-MS/MS bioanalysis of loratadine (Claritin) in dried blood spot (DBS) samples collected by subjects in a clinical research study.
    Li W; Doherty J; Moench P; Flarakos J; Tse FL
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Mar; 983-984():117-24. PubMed ID: 25645810
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Multiplexed steroid profiling of gluco- and mineralocorticoids pathways using a liquid chromatography tandem mass spectrometry method.
    Travers S; Martinerie L; Bouvattier C; Boileau P; Lombès M; Pussard E
    J Steroid Biochem Mol Biol; 2017 Jan; 165(Pt B):202-211. PubMed ID: 27339652
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Volumetric absorptive microsampling as an alternative sampling strategy for the determination of paracetamol in blood and cerebrospinal fluid.
    Delahaye L; Dhont E; De Cock P; De Paepe P; Stove CP
    Anal Bioanal Chem; 2019 Jan; 411(1):181-191. PubMed ID: 30353218
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Volumetric absorptive microsampling as an alternative tool for therapeutic drug monitoring of first-generation anti-epileptic drugs.
    Velghe S; Stove CP
    Anal Bioanal Chem; 2018 Mar; 410(9):2331-2341. PubMed ID: 29362853
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Quantitative bioanalysis of paracetamol in rats using volumetric absorptive microsampling (VAMS).
    Denniff P; Parry S; Dopson W; Spooner N
    J Pharm Biomed Anal; 2015 Apr; 108():61-9. PubMed ID: 25710904
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dried haematic microsamples and LC-MS/MS for the analysis of natural and synthetic cannabinoids.
    Protti M; Rudge J; Sberna AE; Gerra G; Mercolini L
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Feb; 1044-1045():77-86. PubMed ID: 28088044
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Application of a new volumetric microsampling device for quantitative bioanalysis of immunosuppression.
    Leino AD; Takyi-Williams J; Wen B; Sun D; Pai MP
    Bioanalysis; 2022 Sep; 14(17):1141-1152. PubMed ID: 36208082
    [No Abstract]   [Full Text] [Related]  

  • 28. LC-MS/MS measurement of endogenous steroid hormones and phase II metabolites in blood volumetric absorptive microsampling (VAMS) for doping control purposes.
    Ponzetto F; Parasiliti-Caprino M; Leoni L; Marinelli L; Nonnato A; Nicoli R; Kuuranne T; Ghigo E; Mengozzi G; Settanni F
    Clin Chim Acta; 2024 Apr; 557():117890. PubMed ID: 38537673
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Volumetric absorptive MicroSampling vs. other blood sampling materials in LC-MS-based protein analysis - preliminary investigations.
    Andersen IKL; Rosting C; Gjelstad A; Halvorsen TG
    J Pharm Biomed Anal; 2018 Jul; 156():239-246. PubMed ID: 29729637
    [TBL] [Abstract][Full Text] [Related]  

  • 30. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.
    Bruschettini M; Barco S; Romantsik O; Risso F; Gennai I; Chinea B; Ramenghi LA; Tripodi G; Cangemi G
    Bioanalysis; 2016 Sep; 8(18):1893-902. PubMed ID: 27532249
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Dried Blood Spot Multiplexed Steroid Profiling Using Liquid Chromatography Tandem Mass Spectrometry in Korean Neonates.
    Choi R; Park HD; Oh HJ; Lee K; Song J; Lee SY
    Ann Lab Med; 2019 May; 39(3):263-270. PubMed ID: 30623618
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development, validation, and application of a quantitative volumetric absorptive microsampling-based method in finger prick blood by means of LC-HRMS/MS applicable for adherence monitoring of antipsychotics.
    Jacobs CM; Wagmann L; Meyer MR
    Anal Bioanal Chem; 2021 Mar; 413(6):1729-1737. PubMed ID: 33517479
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Drug monitoring by volumetric absorptive microsampling: method development considerations to mitigate hematocrit effects.
    Fang K; Bowen CL; Kellie JF; Karlinsey MZ; Evans CA
    Bioanalysis; 2018 Feb; 10(4):241-255. PubMed ID: 29333871
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A volumetric absorptive microsampling LC-MS/MS method for five immunosuppressants and their hematocrit effects.
    Koster RA; Niemeijer P; Veenhof H; Hateren KV; Alffenaar JC; Touw DJ
    Bioanalysis; 2019 Mar; 11(6):495-508. PubMed ID: 30892068
    [No Abstract]   [Full Text] [Related]  

  • 35. Volumetric Absorptive Microsampling (VAMS) for Targeted LC-MS/MS Determination of Tryptophan-Related Biomarkers.
    Protti M; Cirrincione M; Mandrioli R; Rudge J; Regazzoni L; Valsecchi V; Volpi C; Mercolini L
    Molecules; 2022 Sep; 27(17):. PubMed ID: 36080419
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hematocrit prediction in volumetric absorptive microsamples.
    Capiau S; Stove C
    J Pharm Biomed Anal; 2020 Oct; 190():113491. PubMed ID: 32777731
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Measurement of steroids in rats after exposure to an endocrine disruptor: mass spectrometry and radioimmunoassay demonstrate similar results.
    Riffle BW; Henderson WM; Laws SC
    J Pharmacol Toxicol Methods; 2013; 68(3):314-22. PubMed ID: 23871967
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Volumetric absorptive microsampling (VAMS®) in therapeutic protein quantification by LC-MS/MS: Investigation of anticoagulant impact on assay performance and recommendations for best practices in method development.
    Gao X; Chen C; Geng D; Bateman KP; Shi S; Woolf EJ; Xu Y
    J Pharm Biomed Anal; 2021 Mar; 196():113895. PubMed ID: 33486450
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Determination of oxycodone and its major metabolites in haematic and urinary matrices: Comparison of traditional and miniaturised sampling approaches.
    Protti M; Catapano MC; Samolsky Dekel BG; Rudge J; Gerra G; Somaini L; Mandrioli R; Mercolini L
    J Pharm Biomed Anal; 2018 Apr; 152():204-214. PubMed ID: 29414014
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of sample extraction methods for minimizing hematocrit effect on whole blood analysis with volumetric absorptive microsampling.
    Ye Z; Gao H
    Bioanalysis; 2017 Feb; 9(4):349-357. PubMed ID: 28102694
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.