These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 2819211)

  • 1. [Is the stress period a useful parameter for rate adapted heart stimulation?].
    Niederlag W; Rentsch W; Wunderlich E; Schmidt PK
    Biomed Tech (Berl); 1989; 34 Suppl():62-5. PubMed ID: 2819211
    [No Abstract]   [Full Text] [Related]  

  • 2. [Rate adaptive cardiac pacemakers: a comparison of impulse and acceleration proportional control].
    Hubmann M; Weikl A; Hardt R; Schaldach M
    Biomed Tech (Berl); 1989; 34 Suppl():57-9. PubMed ID: 2819209
    [No Abstract]   [Full Text] [Related]  

  • 3. [Analysis of myocardial evoked potentials in relation to ergometric load and heart rate for use in frequency-adaptive cardiac pacemakers].
    Wetzig T; Fischer G; Worth H; Hardt R; Hubmann M; Bolz A; Schaldach M
    Biomed Tech (Berl); 1995; 40(1-2):9-13. PubMed ID: 7703348
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Behavior of various activity-controlled cardiac pacemakers in treadmill stress tests with variable slopes].
    Matula M; Hölzer K; Zitzmann E; Schön H; Alt E
    Z Kardiol; 1993 Feb; 82(2):108-15. PubMed ID: 8465563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The dromotropic pacemaker: system analysis and design considerations.
    Hexamer M; Meine M; Kloppe C; Kloppe A; Mügge A; Werner J
    Biomed Tech (Berl); 2004 Nov; 49(11):300-5. PubMed ID: 15624866
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Validation of control circuit behavior in frequency-adapted stimulation by interference responses].
    Polley R; Malinowski K; Schaldach M
    Biomed Tech (Berl); 1997; 42 Suppl():273-4. PubMed ID: 9517148
    [No Abstract]   [Full Text] [Related]  

  • 7. [Principle of the activity-controlled rate-adaptive cardiac pacemaker: analysis of stress and environment-induced mechanical effects on the human body].
    Alt E; Matula M; Theres H; Heinz M
    Z Kardiol; 1989 Sep; 78(9):587-97. PubMed ID: 2815913
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation by serial standardized testing of a new rate-responsive pacemaker sensor based on variations in myocardial contractility.
    Clémenty J; Kobeissi A; Garrigue S; Jaïs P; Le Métayer P; Haïssaguerre M
    Europace; 2001 Apr; 3(2):124-31. PubMed ID: 11333049
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Pre-ejection period controlled cardiac pacemaker].
    Schaldach M
    Biomed Tech (Berl); 1989; 34(7-8):177-84. PubMed ID: 2775824
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparison of rate adapted cardiac pacemakers--advantages and weaknesses].
    Zegelman M; Kreuzer J; Rahn R; Beyersdorf F; Wagner R
    Biomed Tech (Berl); 1989; 34 Suppl():60-1. PubMed ID: 2819210
    [No Abstract]   [Full Text] [Related]  

  • 11. Basic principles of permanent cardiac pacing.
    Rozkovec A
    Br J Hosp Med; 1996 Jan 17-Feb 6; 55(1-2):31-7. PubMed ID: 8646389
    [No Abstract]   [Full Text] [Related]  

  • 12. [Analysis of the course of heart rate].
    Tiesler G
    Biomed Tech (Berl); 1989; 34 Suppl():36-7. PubMed ID: 2819199
    [No Abstract]   [Full Text] [Related]  

  • 13. [Analysis of ventricular evoked action potential for the detection of chronotropic status].
    Potschadtke J; Dauer W; Bolz A; Schaldach M
    Biomed Tech (Berl); 1997; 42 Suppl():135-6. PubMed ID: 9517083
    [No Abstract]   [Full Text] [Related]  

  • 14. [Implantable pacemaker with multi-sensor control].
    Schaldach M
    Biomed Tech (Berl); 1990; 35 Suppl 3():134-7. PubMed ID: 2078666
    [No Abstract]   [Full Text] [Related]  

  • 15. [3-dimensional activity analysis with activity sensors for pacemaker therapy].
    Hoeland K; Meine M; Hexamer M; Werner J
    Biomed Tech (Berl); 1998; 43 Suppl():368-9. PubMed ID: 9859402
    [No Abstract]   [Full Text] [Related]  

  • 16. [Holter functions in cardiac pacemakers: expanding diagnostic possibilities and their clinical relevance].
    Stangl K; Wirtzfeld A; Sichart U
    Z Kardiol; 1988 May; 77(5):325-32. PubMed ID: 3407278
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Non-invasive continuous monitoring of heart function using miniaturized scintillation detectors and attached computer system].
    Fridrich L; Heute D; Mutz N; Benzer H; Stöger A; Klicpera M; Riccabona G
    Biomed Tech (Berl); 1990; 35 Suppl 2():57-8. PubMed ID: 2224027
    [No Abstract]   [Full Text] [Related]  

  • 18. [A new cardiac pacemaker stimulation technology (autocapture) allows, with unchanged life expectancy, reduction of generator size by half].
    Antretter H; Bonatti J; Cottogni M; Hangler H; Müller LC; Mair P; Dapunt OE
    Acta Med Austriaca; 1996; 23(5):159-64. PubMed ID: 9082745
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Controlled frequency-adapted stimulation of the heart based on mathematical identification of the cardiovascular system].
    Urbaszek A; Schaldach M
    Biomed Tech (Berl); 1997; 42 Suppl():73-4. PubMed ID: 9517052
    [No Abstract]   [Full Text] [Related]  

  • 20. [The characteristic wave intervals of exercise ECG influenced by changing of heart rate].
    Ye J; Zheng C; Huang Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1999 Mar; 16(1):50-3, 76. PubMed ID: 12553276
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.