These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 28192285)

  • 1. Real-time detection of fast and thermal neutrons in radiotherapy with CMOS sensors.
    Arbor N; Higueret S; Elazhar H; Combe R; Meyer P; Dehaynin N; Taupin F; Husson D
    Phys Med Biol; 2017 Mar; 62(5):1920-1934. PubMed ID: 28192285
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy.
    Sakurai Y; Tanaka H; Kondo N; Kinashi Y; Suzuki M; Masunaga S; Ono K; Maruhashi A
    Med Phys; 2015 Nov; 42(11):6651-7. PubMed ID: 26520755
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The neutron sensitivity of dosimeters applied to boron neutron capture therapy.
    Raaijmakers CP; Watkins PR; Nottelman EL; Verhagen HW; Jansen JT; Zoetelief J; Mijnheer BJ
    Med Phys; 1996 Sep; 23(9):1581-9. PubMed ID: 8892256
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Neutron flow measurements in the d(14) + Be neutron radiation field from the cyclotron in Essen].
    Pöller F; Sauerwein W; Rau D; Wagner FM; Olthoff K; Rassow J; Sack H
    Strahlenther Onkol; 1990 Jun; 166(6):426-9. PubMed ID: 2363106
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neutron measurements in radiotherapy: A method to correct neutron sensitive devices for parasitic photon response.
    Irazola L; Terrón JA; Bedogni R; Pola A; Lorenzoli M; Jimenez-Ortega E; Barbeiro AR; Sánchez-Nieto B; Sánchez-Doblado F
    Appl Radiat Isot; 2017 May; 123():32-35. PubMed ID: 28214683
    [TBL] [Abstract][Full Text] [Related]  

  • 6. European protocol for neutron dosimetry for external beam therapy. European Clinical Neutron Dosimetry Group (ECNEU).
    Broerse JJ; Mijnheer BJ; Williams JR
    Br J Radiol; 1981 Oct; 54(646):882-98. PubMed ID: 6794701
    [No Abstract]   [Full Text] [Related]  

  • 7. Empirical description and Monte Carlo simulation of fast neutron pencil beams as basis of a treatment planning system.
    Bourhis-Martin E; Meissner P; Rassow J; Baumhoer W; Schmidt R; Sauerwein W
    Med Phys; 2002 Aug; 29(8):1670-7. PubMed ID: 12201412
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of the thermal neutron flux in a fast neutron beam by use of a boron-coated ionization chamber.
    Lüdemann L; Matzen T; Matzke M; Schmidt R; Scobel W
    Med Phys; 1995 Nov; 22(11 Pt 1):1743-7. PubMed ID: 8587527
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of a pencil beam model-based treatment planning system for fast neutron therapy.
    Bourhis-Martin E; Meissner P; Rassow J; Baumhoer W; Schmidt R; Sauerwein W
    Med Phys; 2003 Jan; 30(1):21-6. PubMed ID: 12557974
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Neutron measurements with ultra-thin 3D silicon sensors in a radiotherapy treatment room using a Siemens PRIMUS linac.
    Guardiola C; Gómez F; Fleta C; Rodríguez J; Quirion D; Pellegrini G; Lousa A; Martínez-de-Olcoz L; Pombar M; Lozano M
    Phys Med Biol; 2013 May; 58(10):3227-42. PubMed ID: 23611848
    [TBL] [Abstract][Full Text] [Related]  

  • 11. DISCRIMINATION METHOD FOR GAMMA RAY DOSES IN NEUTRON FIELDS USING AN IONIZATION CHAMBER WITH ATTENUATION FILTERS.
    Ogawara R; Suda M; Hagihara T; Kodaira S; Hamano T
    Radiat Prot Dosimetry; 2019 May; 183(1-2):280-284. PubMed ID: 30726975
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A study on the optimum fast neutron flux for boron neutron capture therapy of deep-seated tumors.
    Rasouli FS; Masoudi SF
    Appl Radiat Isot; 2015 Feb; 96():45-51. PubMed ID: 25479433
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz.
    Schmitz T; Blaickner M; Schütz C; Wiehl N; Kratz JV; Bassler N; Holzscheiter MH; Palmans H; Sharpe P; Otto G; Hampel G
    Acta Oncol; 2010 Oct; 49(7):1165-9. PubMed ID: 20831509
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measuring neutron spectra in radiotherapy using the nested neutron spectrometer.
    Maglieri R; Licea A; Evans M; Seuntjens J; Kildea J
    Med Phys; 2015 Nov; 42(11):6162-9. PubMed ID: 26520709
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo simulation of the response of ESR dosimeters added with gadolinium exposed to thermal, epithermal and fast neutrons.
    Marrale M; Basile S; Brai M; Longo A
    Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S186-9. PubMed ID: 19380235
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Triple chamber technique for thermal neutron dose measurements in fast neutron beams.
    Schmidt R; Hess A
    Strahlentherapie; 1982 Oct; 158(10):612-5. PubMed ID: 7179343
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fluence measurement of fast neutron fields with a highly efficient recoil proton telescope using active pixel sensors.
    Taforeau J; Higueret S; Husson D; Kachel M; Lebreton L
    Radiat Prot Dosimetry; 2014 Oct; 161(1-4):41-5. PubMed ID: 24243312
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Feasibility study on using imaging plates to estimate thermal neutron fluence in neutron-gamma mixed fields.
    Fujibuchi T; Tanabe Y; Sakae T; Terunuma T; Isobe T; Kawamura H; Yasuoka K; Matsumoto T; Harano H; Nishiyama J; Masuda A; Nohtomi A
    Radiat Prot Dosimetry; 2011 Nov; 147(3):394-400. PubMed ID: 21196463
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Study on the measurement of photo-neutron for15 MV photon beam from medical linear accelerator under different irradiation geometries using passive detectors.
    Thekkedath SC; Raman RG; Musthafa MM; Bakshi AK; Pal R; Dawn S; Kummali AH; Huilgol NG; Selvam TP; Datta D
    J Cancer Res Ther; 2016; 12(2):1060-4. PubMed ID: 27461699
    [TBL] [Abstract][Full Text] [Related]  

  • 20. CHARACTERIZATION OF A THIN SILICON SENSOR FOR ACTIVE NEUTRON PERSONAL DOSEMETERS.
    Takada M; Nunomiya T; Nakamura T; Matsumoto T; Masuda A
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):213-7. PubMed ID: 27150515
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.