These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
203 related articles for article (PubMed ID: 28197582)
1. Wearable microfluidics: fabric-based digital droplet flowmetry for perspiration analysis. Yang Y; Xing S; Fang Z; Li R; Koo H; Pan T Lab Chip; 2017 Feb; 17(5):926-935. PubMed ID: 28197582 [TBL] [Abstract][Full Text] [Related]
2. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat. Koh A; Kang D; Xue Y; Lee S; Pielak RM; Kim J; Hwang T; Min S; Banks A; Bastien P; Manco MC; Wang L; Ammann KR; Jang KI; Won P; Han S; Ghaffari R; Paik U; Slepian MJ; Balooch G; Huang Y; Rogers JA Sci Transl Med; 2016 Nov; 8(366):366ra165. PubMed ID: 27881826 [TBL] [Abstract][Full Text] [Related]
3. A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis. Nyein HYY; Tai LC; Ngo QP; Chao M; Zhang GB; Gao W; Bariya M; Bullock J; Kim H; Fahad HM; Javey A ACS Sens; 2018 May; 3(5):944-952. PubMed ID: 29741360 [TBL] [Abstract][Full Text] [Related]
4. All fabric and flexible wearable sensors for simultaneous sweat metabolite detection and high-efficiency collection. Zhang Y; Liao J; Li Z; Hu M; Bian C; Lin S Talanta; 2023 Aug; 260():124610. PubMed ID: 37146456 [TBL] [Abstract][Full Text] [Related]
5. A thread/fabric-based band as a flexible and wearable microfluidic device for sweat sensing and monitoring. Zhao Z; Li Q; Chen L; Zhao Y; Gong J; Li Z; Zhang J Lab Chip; 2021 Mar; 21(5):916-932. PubMed ID: 33438703 [TBL] [Abstract][Full Text] [Related]
6. Digital nanoliter to milliliter flow rate sensor with in vivo demonstration for continuous sweat rate measurement. Francis J; Stamper I; Heikenfeld J; Gomez EF Lab Chip; 2018 Dec; 19(1):178-185. PubMed ID: 30525141 [TBL] [Abstract][Full Text] [Related]
7. Digital microfluidic meter-on-chip. Fang Z; Ding Y; Zhang Z; Wang F; Wang Z; Wang H; Pan T Lab Chip; 2020 Feb; 20(4):722-733. PubMed ID: 31853525 [TBL] [Abstract][Full Text] [Related]
8. Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities. Kim S; Lee B; Reeder JT; Seo SH; Lee SU; Hourlier-Fargette A; Shin J; Sekine Y; Jeong H; Oh YS; Aranyosi AJ; Lee SP; Model JB; Lee G; Seo MH; Kwak SS; Jo S; Park G; Han S; Park I; Jung HI; Ghaffari R; Koo J; Braun PV; Rogers JA Proc Natl Acad Sci U S A; 2020 Nov; 117(45):27906-27915. PubMed ID: 33106394 [TBL] [Abstract][Full Text] [Related]
9. Stretchable and Smart Wettable Sensing Patch with Guided Liquid Flow for Multiplexed Sun Y; Wang J; Lu Q; Fang T; Wang S; Yang C; Lin Y; Wang Q; Lu YQ; Kong D ACS Nano; 2024 Jan; 18(3):2335-2345. PubMed ID: 38189251 [TBL] [Abstract][Full Text] [Related]
11. Hydrogel-enabled osmotic pumping for microfluidics: towards wearable human-device interfaces. Shay T; Dickey MD; Velev OD Lab Chip; 2017 Feb; 17(4):710-716. PubMed ID: 28150821 [TBL] [Abstract][Full Text] [Related]
12. A wearable lab-on-a-patch platform with stretchable nanostructured biosensor for non-invasive immunodetection of biomarker in sweat. Lee HB; Meeseepong M; Trung TQ; Kim BY; Lee NE Biosens Bioelectron; 2020 May; 156():112133. PubMed ID: 32174559 [TBL] [Abstract][Full Text] [Related]
13. A wearable patch for continuous monitoring of sweat electrolytes during exertion. Alizadeh A; Burns A; Lenigk R; Gettings R; Ashe J; Porter A; McCaul M; Barrett R; Diamond D; White P; Skeath P; Tomczak M Lab Chip; 2018 Aug; 18(17):2632-2641. PubMed ID: 30063233 [TBL] [Abstract][Full Text] [Related]
14. A Step Forward for Smart Clothes─Fabric-Based Microfluidic Sensors for Wearable Health Monitoring. Zhang T; Ratajczak AM; Chen H; Terrell JA; Chen C ACS Sens; 2022 Dec; 7(12):3857-3866. PubMed ID: 36455259 [TBL] [Abstract][Full Text] [Related]
15. Microfluidics by Additive Manufacturing for Wearable Biosensors: A Review. Padash M; Enz C; Carrara S Sensors (Basel); 2020 Jul; 20(15):. PubMed ID: 32751404 [TBL] [Abstract][Full Text] [Related]
16. An epidermal wearable microfluidic patch for simultaneous sampling, storage, and analysis of biofluids with counterion monitoring. Paul Kunnel B; Demuru S Lab Chip; 2022 May; 22(9):1793-1804. PubMed ID: 35316321 [TBL] [Abstract][Full Text] [Related]
17. Wearable tesla valve-based sweat collection device for sweat colorimetric analysis. Shi H; Cao Y; Zeng Y; Zhou Y; Wen W; Zhang C; Zhao Y; Chen Z Talanta; 2022 Apr; 240():123208. PubMed ID: 34998143 [TBL] [Abstract][Full Text] [Related]
18. Soft, Skin-Interfaced Microfluidic Systems with Passive Galvanic Stopwatches for Precise Chronometric Sampling of Sweat. Bandodkar AJ; Choi J; Lee SP; Jeang WJ; Agyare P; Gutruf P; Wang S; Sponenburg RA; Reeder JT; Schon S; Ray TR; Chen S; Mehta S; Ruiz S; Rogers JA Adv Mater; 2019 Aug; 31(32):e1902109. PubMed ID: 31206791 [TBL] [Abstract][Full Text] [Related]
19. Microfluidic solutions for biofluids handling in on-skin wearable systems. Kashaninejad N; Nguyen NT Lab Chip; 2023 Mar; 23(5):913-937. PubMed ID: 36628970 [TBL] [Abstract][Full Text] [Related]