244 related articles for article (PubMed ID: 28207758)
1. An improved schlieren method for measurement and automatic reconstruction of the far-field focal spot.
Wang Z; Hu B; Yin Q
PLoS One; 2017; 12(2):e0171415. PubMed ID: 28207758
[TBL] [Abstract][Full Text] [Related]
2. Imaging properties of digital magnification radiography.
Boyce SJ; Samei E
Med Phys; 2006 Apr; 33(4):984-96. PubMed ID: 16696475
[TBL] [Abstract][Full Text] [Related]
3. Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector.
Russo P; Mettivier G
Med Phys; 2011 Apr; 38(4):2099-115. PubMed ID: 21626943
[TBL] [Abstract][Full Text] [Related]
4. Effects of ray profile modeling on resolution recovery in clinical CT.
Hofmann C; Knaup M; Kachelrieß M
Med Phys; 2014 Feb; 41(2):021907. PubMed ID: 24506628
[TBL] [Abstract][Full Text] [Related]
5. A new method for the automated alignment of dental radiographs for digital subtraction radiography.
Yoon DC
Dentomaxillofac Radiol; 2000 Jan; 29(1):11-9. PubMed ID: 10654031
[TBL] [Abstract][Full Text] [Related]
6. Quantitative measurement of acoustic pressure in the focal zone of acoustic lens-line focusing using the Schlieren method.
Jiang X; Cheng Q; Xu Z; Qian M; Han Q
Appl Opt; 2016 Apr; 55(10):2478-83. PubMed ID: 27139646
[TBL] [Abstract][Full Text] [Related]
7. Fully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac CT reconstruction.
Isola AA; Grass M; Niessen WJ
Med Phys; 2010 Mar; 37(3):1093-109. PubMed ID: 20384245
[TBL] [Abstract][Full Text] [Related]
8. Focal spot motion of linear accelerators and its effect on portal image analysis.
Sonke JJ; Brand B; van Herk M
Med Phys; 2003 Jun; 30(6):1067-75. PubMed ID: 12852530
[TBL] [Abstract][Full Text] [Related]
9. Dual focal-spot imaging for phase extraction in phase-contrast radiography.
Donnelly EF; Price RR; Pickens DR
Med Phys; 2003 Sep; 30(9):2292-6. PubMed ID: 14528949
[TBL] [Abstract][Full Text] [Related]
10. Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot.
Flohr TG; Stierstorfer K; Ulzheimer S; Bruder H; Primak AN; McCollough CH
Med Phys; 2005 Aug; 32(8):2536-47. PubMed ID: 16193784
[TBL] [Abstract][Full Text] [Related]
11. [A GPU-based fast volume CT reconstructive algorithm method].
Li Z; Zhou F; Bai X
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Apr; 28(2):238-42. PubMed ID: 21604476
[TBL] [Abstract][Full Text] [Related]
12. X-ray focal spot reconstruction by circular penumbra analysis-Application to digital radiography systems.
Di Domenico G; Cardarelli P; Contillo A; Taibi A; Gambaccini M
Med Phys; 2016 Jan; 43(1):294. PubMed ID: 26745922
[TBL] [Abstract][Full Text] [Related]
13. Lobe based image reconstruction in Electrical Impedance Tomography.
Schullcke B; Gong B; Krueger-Ziolek S; Tawhai M; Adler A; Mueller-Lisse U; Moeller K
Med Phys; 2017 Feb; 44(2):426-436. PubMed ID: 28121374
[TBL] [Abstract][Full Text] [Related]
14. Quantitative image-based spectral reconstruction for computed tomography.
Heismann B; Balda M
Med Phys; 2009 Oct; 36(10):4471-85. PubMed ID: 19928078
[TBL] [Abstract][Full Text] [Related]
15. Measurement of focal spot size with slit camera using computed radiography and flat-panel based digital detectors.
Rong XJ; Krugh KT; Shepard SJ; Geiser WR
Med Phys; 2003 Jul; 30(7):1768-75. PubMed ID: 12906194
[TBL] [Abstract][Full Text] [Related]
16. Comparison of advanced iterative reconstruction methods for SPECT/CT.
Knoll P; Kotalova D; Köchle G; Kuzelka I; Minear G; Mirzaei S; Sámal M; Zadrazil L; Bergmann H
Z Med Phys; 2012 Feb; 22(1):58-69. PubMed ID: 21723716
[TBL] [Abstract][Full Text] [Related]
17. Laser Spot Center Location Method for Chinese Spaceborne GF-7 Footprint Camera.
Ren C; Xie J; Zhi X; Yang Y; Yang S
Sensors (Basel); 2020 Apr; 20(8):. PubMed ID: 32325678
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of cost functions for gray value matching of two-dimensional images in radiotherapy.
Dekker N; Ploeger LS; van Herk M
Med Phys; 2003 May; 30(5):778-84. PubMed ID: 12772984
[TBL] [Abstract][Full Text] [Related]
19. Quantification of the effect of system and object parameters on edge enhancement in phase-contrast radiography.
Donnelly EF; Price RR; Pickens DR
Med Phys; 2003 Nov; 30(11):2888-96. PubMed ID: 14655935
[TBL] [Abstract][Full Text] [Related]
20. Hybrid segmentation of mass in mammograms using template matching and dynamic programming.
Song E; Xu S; Xu X; Zeng J; Lan Y; Zhang S; Hung CC
Acad Radiol; 2010 Nov; 17(11):1414-24. PubMed ID: 20817575
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]