These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 28211105)

  • 21. Ictal SPECT in neocortical epilepsies: clinical usefulness and factors affecting the pattern of hyperperfusion.
    Lee SK; Lee SY; Yun CH; Lee HY; Lee JS; Lee DS
    Neuroradiology; 2006 Sep; 48(9):678-84. PubMed ID: 16896909
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of injection time on rates of epileptogenic zone localization using SISCOM and STATISCOM.
    Hlauschek G; Sinclair B; Brinkmann B; Fuge J; Kwan P; O'Brien TJ; Vivash L
    Epilepsy Behav; 2021 May; 118():107945. PubMed ID: 33845344
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Development of a new method of high-speed rotation multiplied projection single photon emission computed tomography of the triple-headed type: lung MAA SPECT based on phantom study].
    Iwanaga H; Oishi Y; Suga K
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2006 Jun; 62(6):848-54. PubMed ID: 16799413
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Ictal single-photon emission computed tomography imaging in extra temporal lobe epilepsy using statistical parametric mapping.
    Knowlton RC; Lawn ND; Mountz JM; Buddhiwardhan O; Miller S; Burneo JG; Kuzniecky RI
    J Neuroimaging; 2004 Oct; 14(4):324-30. PubMed ID: 15358952
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Computer-aided intrapatient comparison of brain SPECT images: the gray-level normalization issue applied to children with epilepsy.
    Pérault C; Papathanassiou D; Wampach H; Véra P; Kaminska A; Chiron C; Peruzzi P; Liehn JC
    J Nucl Med; 2002 Jun; 43(6):715-24. PubMed ID: 12050314
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Repeated ictal SPECT in partial epilepsy patients: SISCOM analysis.
    Lee JY; Joo EY; Park HS; Song P; Young Byun S; Seo DW; Hong SB
    Epilepsia; 2011 Dec; 52(12):2249-56. PubMed ID: 21913912
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Quantitative and clinical analysis of SPECT image registration for epilepsy studies.
    Brinkmann BH; O'Brien TJ; Aharon S; O'Connor MK; Mullan BP; Hanson DP; Robb RA
    J Nucl Med; 1999 Jul; 40(7):1098-105. PubMed ID: 10405126
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Optimization of
    Alqahtani MM; Willowson KP; Constable C; Fulton R; Kench PL
    J Appl Clin Med Phys; 2022 Apr; 23(4):e13528. PubMed ID: 35049129
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A comparison of 180 degrees and 360 degrees acquisition for attenuation-compensated thallium-201 SPECT images.
    LaCroix KJ; Tsui BM; Hasegawa BH
    J Nucl Med; 1998 Mar; 39(3):562-74. PubMed ID: 9529312
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Patient-specific estimation of spatially variant image noise for a pinhole cardiac SPECT camera.
    Cuddy-Walsh SG; Wells RG
    Med Phys; 2018 May; 45(5):2033-2047. PubMed ID: 29574767
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ictogenesis and symptomatogenesis of gelastic seizures in hypothalamic hamartomas: an ictal SPECT study.
    Kameyama S; Masuda H; Murakami H
    Epilepsia; 2010 Nov; 51(11):2270-9. PubMed ID: 20887368
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A blind deconvolution method incorporated with anatomical-based filtering for partial volume correction: Validations with
    Wu J; Liu H; Hashemi Zonouz T; Sandoval VM; Mohy-Ud-Din H; Lampert RJ; Sinusas AJ; Liu C; Liu YH
    Med Phys; 2017 Dec; 44(12):6435-6446. PubMed ID: 28994458
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
    Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
    J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
    [TBL] [Abstract][Full Text] [Related]  

  • 34. ROC and LROC analyses of the effects of lesion contrast, size, and signal-to-noise ratio on detectability in PET images.
    Farquhar TH; Llacer J; Sayre J; Tai YC; Hoffman EJ
    J Nucl Med; 2000 Apr; 41(4):745-54. PubMed ID: 10768578
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Interictal PET and ictal subtraction SPECT: sensitivity in the detection of seizure foci in patients with medically intractable epilepsy.
    Desai A; Bekelis K; Thadani VM; Roberts DW; Jobst BC; Duhaime AC; Gilbert K; Darcey TM; Studholme C; Siegel A
    Epilepsia; 2013 Feb; 54(2):341-50. PubMed ID: 23030361
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Performance of a SPECT collimator-detector response reconstruction algorithm: phantom studies and validation in inflammation clinical studies.
    Arosio M; Pasquali C; Crivellaro C; De Ponti E; Morzenti S; Guerra L; Crespi A; Messa C
    Q J Nucl Med Mol Imaging; 2011 Dec; 55(6):671-9. PubMed ID: 21285924
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Intracranial ictal onset zone in nonlesional lateral temporal lobe epilepsy on scalp ictal EEG.
    Lee SK; Yun CH; Oh JB; Nam HW; Jung SW; Paeng JC; Lee DS; Chung CK; Choe G
    Neurology; 2003 Sep; 61(6):757-64. PubMed ID: 14504317
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging.
    Hulme KW; Kappadath SC
    Med Phys; 2014 Apr; 41(4):042502. PubMed ID: 24694155
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Noise suppressed partial volume correction for cardiac SPECT/CT.
    Chan C; Liu H; Grobshtein Y; Stacy MR; Sinusas AJ; Liu C
    Med Phys; 2016 Sep; 43(9):5225. PubMed ID: 27587054
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks.
    Ghaly M; Du Y; Links JM; Frey EC
    Phys Med Biol; 2016 Mar; 61(5):2048-66. PubMed ID: 26895287
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.