These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 28212136)

  • 1. Impact of different values of prosthesis-patient mismatch on outcome in male patients with aortic valve replacement.
    Mannacio VA; Mannacio L; Antignano A; Pinna GB; Giordano R; Mottola M; Iannelli G
    J Cardiovasc Med (Hagerstown); 2017 May; 18(5):366-373. PubMed ID: 28212136
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of aortic prosthesis-patient mismatch on left ventricular mass regression.
    Alassal MA; Ibrahim BM; Elsadeck N
    Asian Cardiovasc Thorac Ann; 2014 Jun; 22(5):546-50. PubMed ID: 24867028
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prosthesis-patient mismatch in high-risk patients with severe aortic stenosis: A randomized trial of a self-expanding prosthesis.
    Zorn GL; Little SH; Tadros P; Deeb GM; Gleason TG; Heiser J; Kleiman NS; Oh JK; Popma JJ; Adams D; Huang J; Reardon MJ
    J Thorac Cardiovasc Surg; 2016 Apr; 151(4):1014-22, 1023.e1-3. PubMed ID: 26614412
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prosthesis-patient mismatch in bovine pericardial aortic valves: evaluation using 3 different modalities and associated medium-term outcomes.
    Chacko SJ; Ansari AH; McCarthy PM; Malaisrie SC; Andrei AC; Li Z; Lee R; McGee E; Bonow RO; Puthumana JJ
    Circ Cardiovasc Imaging; 2013 Sep; 6(5):776-83. PubMed ID: 23926194
    [TBL] [Abstract][Full Text] [Related]  

  • 5. CT-Defined Prosthesis-Patient Mismatch Downgrades Frequency and Severity, and Demonstrates No Association With Adverse Outcomes After Transcatheter Aortic Valve Replacement.
    Mooney J; Sellers SL; Blanke P; Pibarot P; Hahn RT; Dvir D; Douglas PS; Weissman NJ; Kodali SK; Thourani VH; Jilaihawi H; Khalique O; Smith CR; Kueh SH; Ohana M; Grover R; Naoum C; Crowley A; Jaber WA; Alu MC; Parvataneni R; Mack M; Webb JG; Leon MB; Leipsic JA
    JACC Cardiovasc Interv; 2017 Aug; 10(15):1578-1587. PubMed ID: 28734891
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Patient-prosthesis mismatch and left ventricular remodelling after implantation of Shelhigh SuperStentless aortic valve prostheses.
    Germing A; Lindstaedt M; Holt S; Reber D; Mügge A; Laczkovics A; Fritz M
    J Cardiovasc Surg (Torino); 2008 Aug; 49(4):539-43. PubMed ID: 18665119
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences.
    Pisano C; D'Amico T; Palmeri C; Franchino R; Fattouch K; Bianco G; Ruvolo G
    Interact Cardiovasc Thorac Surg; 2011 Dec; 13(6):606-10. PubMed ID: 21891800
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients.
    Haverich A; Wahlers TC; Borger MA; Shrestha M; Kocher AA; Walther T; Roth M; Misfeld M; Mohr FW; Kempfert J; Dohmen PM; Schmitz C; Rahmanian P; Wiedemann D; Duhay FG; Laufer G
    J Thorac Cardiovasc Surg; 2014 Dec; 148(6):2854-60. PubMed ID: 25218544
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN™ prosthesis.
    Van Linden A; Kempfert J; Blumenstein J; Rastan A; Holzhey D; Lehmann S; Mohr FW; Walther T
    Thorac Cardiovasc Surg; 2013 Aug; 61(5):414-20. PubMed ID: 22791205
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement.
    Poulin F; Yingchoncharoen T; Wilson WM; Horlick EM; Généreux P; Tuzcu EM; Stewart W; Osten MD; Woo A; Thavendiranathan P
    J Am Heart Assoc; 2016 Feb; 5(2):. PubMed ID: 26857069
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of valve prosthesis-patient mismatch on intermediate-term outcome and regression of left ventricular mass following aortic valve replacement with mechanical prosthesis.
    Tao K; Sakata R; Iguro Y; Ueno M; Tanaka Y; Otsuji Y; Tei C
    J Card Surg; 2007; 22(6):486-92. PubMed ID: 18039208
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patient-prosthesis mismatch has no influence on in-hospital mortality after aortic valve replacement.
    Yottasurodom C; Namthaisong K; Porapakkham P; Kasemsarn C; Chotivatanapong T; Chaiseri P; Wongdit S; Yasotarin S
    J Med Assoc Thai; 2012 Aug; 95 Suppl 8():S64-70. PubMed ID: 23130477
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement.
    Bleiziffer S; Ali A; Hettich IM; Akdere D; Laubender RP; Ruzicka D; Boehm J; Lange R; Eichinger W
    Heart; 2010 Jun; 96(11):865-71. PubMed ID: 20406767
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of the increase in valve area after aortic valve replacement with a 19-mm aortic valve prosthesis on left ventricular mass regression in patients with pure aortic stenosis.
    Mhagna Z; Tasca G; Brunelli F; Cirillo M; Amaducci A; DallaTomba M; Troise G
    J Cardiovasc Med (Hagerstown); 2006 May; 7(5):351-5. PubMed ID: 16645414
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The CarboMedics supra-annular Top Hat valve improves long-term left ventricular mass regression.
    Mosquera VX; Bouzas-Mosquera A; Bautista-Hernandez V; Estévez-Cid F; Herrera-Noreña JM; Alvarez-García N; Cuenca-Castillo JJ
    J Thorac Cardiovasc Surg; 2014 Dec; 148(6):2845-53.e1. PubMed ID: 25131169
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: a prospective observational study.
    Hong S; Yi G; Youn YN; Lee S; Yoo KJ; Chang BC
    J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1098-104. PubMed ID: 22959323
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stentless and stented aortic valve replacement in elderly patients: Factors affecting midterm clinical and hemodynamical outcome.
    Bové T; Van Belleghem Y; François K; Caes F; Van Overbeke H; Van Nooten G
    Eur J Cardiothorac Surg; 2006 Nov; 30(5):706-13. PubMed ID: 16950630
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Aortic valve replacement in elderly patients with small aortic annulus; is the indexed effective orifice area important?].
    Baba H; Aoki M; Nishimura Y; Hashimoto M; Okawa Y
    Kyobu Geka; 2006 Apr; 59(4):329-35. PubMed ID: 16613153
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prevalence and Impact of Prosthesis-Patient Mismatch Following Surgical Aortic Valve Replacement for Pure Aortic Regurgitation.
    Auffret V; Voisine P; Cinq-Mars A; Charbonneau É; Le Ven F; Dubois-Sénéchal SM; Brenna E; Dagenais F; Dubois M; Ridard C; Sénéchal M
    J Heart Valve Dis; 2016 Sep; 25(5):543-551. PubMed ID: 28238235
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Patient-prosthesis mismatch in aortic valve replacement: really tolerable?
    Fuster RG; Montero Argudo JA; Albarova OG; Sos FH; López SC; Codoñer MB; Buendía Miñano JA; Albarran IR
    Eur J Cardiothorac Surg; 2005 Mar; 27(3):441-9; discussion 449. PubMed ID: 15740953
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.