These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

250 related articles for article (PubMed ID: 28216756)

  • 21. Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach.
    Ali N; Ahmad Mir N; Ahmad Dar T; Nawaz Rather M; Ahmad Mir W; S S; Maajid S
    Bull Emerg Trauma; 2018 Oct; 6(4):306-312. PubMed ID: 30402518
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Internal fixation of proximal humerus fractures using the locking proximal humerus plate.
    Plecko M; Kraus A
    Oper Orthop Traumatol; 2005 Feb; 17(1):25-50. PubMed ID: 16007377
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Effectiveness of locking compress plate and extra cortical bone bridge fixation for treatment of atrophic humeral nonunions].
    Wu M; Guan J; Xiao Y; Dai X; Li Y; Bao Z; Wang Z; Chen X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2017 Jan; 31(1):1-4. PubMed ID: 29798620
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Locking plates in distal humerus fractures: study of 43 patients.
    Gupta RK; Gupta V; Marak DR
    Chin J Traumatol; 2013; 16(4):207-11. PubMed ID: 23910671
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Type C2 proximal humeral fracture fixation using locking-plate with an intramedullary fibular allograft].
    Chen X; Chen H; Zou Y; Feng H; Wu J; Zhang J; Peng Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Feb; 28(2):201-4. PubMed ID: 24796193
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [AO type 13-C distal humerus fractures. Results of surgical treatment].
    Holub K; Kloub M; Kopačka P
    Acta Chir Orthop Traumatol Cech; 2012; 79(6):529-34. PubMed ID: 23286686
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures.
    Vallier HA; Cureton BA; Patterson BM
    J Orthop Trauma; 2011 Dec; 25(12):736-41. PubMed ID: 21904230
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Surgical treatment of humeral diaphyseal fractures].
    Smejkal K; Lochman P; Dědek T; Trlica J
    Acta Chir Orthop Traumatol Cech; 2014; 81(2):129-34. PubMed ID: 25105787
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®.
    Helfen T; Siebenbürger G; Mayer M; Böcker W; Ockert B; Haasters F
    BMC Musculoskelet Disord; 2016 Oct; 17(1):448. PubMed ID: 27793135
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Functional outcome of extra-articular distal humerus fracture fixation using a single locking plate: A retrospective study.
    Trikha V; Agrawal P; Das S; Gaba S; Kumar A
    J Orthop Surg (Hong Kong); 2017; 25(3):2309499017727948. PubMed ID: 28844197
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Effectiveness of AO anatomical locking compression plate in treating type C distal humeral fracture].
    Zhang L; Hu F; Zhang L; Chen H; Xu M; Wang Y; Tang P
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 Dec; 24(12):1409-12. PubMed ID: 21261082
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical evaluation of a modified proximal humeral locking plate application for distal extra-articular diaphyseal humeral fractures.
    Lim JR; Yoon TH; Choi YR; Lee HM; Chun YM
    J Orthop Res; 2021 Sep; 39(9):1877-1883. PubMed ID: 33222233
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Condylar orientation plating in comminuted intraarticular fractures of adult distal humerus.
    Sarkhel S; Bhattacharyya S; Mukherjee S
    Indian J Orthop; 2015; 49(5):523-8. PubMed ID: 26538758
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Role of autologous non-vascularised intramedullary fibular strut graft in humeral shaft nonunions following failed plating.
    Kashayi-Chowdojirao S; Vallurupalli A; Chilakamarri VK; Patnala C; Chodavarapu LM; Kancherla NR; Khazi Syed AH
    J Clin Orthop Trauma; 2017 Nov; 8(Suppl 2):S21-S30. PubMed ID: 29339841
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.
    Shin SJ; Sohn HS; Do NH
    J Orthop Trauma; 2012 Oct; 26(10):585-9. PubMed ID: 22534690
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The functional outcome of operative treatment of ununited fractures of the humeral diaphysis in older patients.
    Ring D; Perey BH; Jupiter JB
    J Bone Joint Surg Am; 1999 Feb; 81(2):177-90. PubMed ID: 10073581
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Clinical study on locking plate for the treatment of non-osteoporotic complex proximal humeral fractures].
    Li X; Li FL; Lu Y; Zhu YM; Guo SY; Li YJ; Jiang CY
    Beijing Da Xue Xue Bao Yi Xue Ban; 2017 Oct; 49(5):855-860. PubMed ID: 29045969
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of Fixation for Distal Humeral Diaphyseal Fracture by Locking Compression Plate.
    Saha MK; Islam SS; Alam S; Rahman MW; Kamruzzaman M; Paul J; Rahman MM; Alamgir MK
    Mymensingh Med J; 2019 Jan; 28(1):60-69. PubMed ID: 30755552
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Functional outcomes of minimal invasive percutaneous plate osteosynthesis (MIPPO) in humerus shaft fractures: a clinical study.
    Huri G; Biçer ÖS; Öztürk H; Deveci MA; Tan I
    Acta Orthop Traumatol Turc; 2014; 48(4):406-12. PubMed ID: 25230263
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Minimally invasive osteosynthesis using helical plate for complex humeral shaft fractures involved proximal metaphysis].
    Wang X; Yin D; Liang B; Jin X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Jul; 30(7):799-802. PubMed ID: 29786312
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.