BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

417 related articles for article (PubMed ID: 28218352)

  • 1. Concomitant pulsatile and continuous flow VAD in biventricular and univentricular physiology: a comparison study with a numerical model.
    Di Molfetta A; Ferrari G; Iacobelli R; Filippelli S; Guccione P; Fresiello L; Perri G; Amodeo A
    Int J Artif Organs; 2017 Mar; 40(2):74-81. PubMed ID: 28218352
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of a Lumped Parameter Model to Study the Feasibility of Simultaneous Implantation of a Continuous Flow Ventricular Assist Device (VAD) and a Pulsatile Flow VAD in BIVAD Patients.
    Di Molfetta A; Ferrari G; Iacobelli R; Filippelli S; Fresiello L; Guccione P; Toscano A; Amodeo A
    Artif Organs; 2017 Mar; 41(3):242-252. PubMed ID: 28281287
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Concurrent use of continuous and pulsatile flow Ventricular Assist Device on a fontan patient: A simulation study.
    Di Molfetta A; Ferrari G; Iacobelli R; Filippelli S; Amodeo A
    Artif Organs; 2017 Jan; 41(1):32-39. PubMed ID: 28025826
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simulation of Ventricular, Cavo-Pulmonary, and Biventricular Ventricular Assist Devices in Failing Fontan.
    Di Molfetta A; Amodeo A; Fresiello L; Trivella MG; Iacobelli R; Pilati M; Ferrari G
    Artif Organs; 2015 Jul; 39(7):550-8. PubMed ID: 25808201
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemodynamic Effects of Ventricular Assist Device Implantation on Norwood, Glenn, and Fontan Circulation: A Simulation Study.
    Di Molfetta A; Amodeo A; Gagliardi MG; Trivella MG; Fresiello L; Filippelli S; Toscano A; Ferrari G
    Artif Organs; 2016 Jan; 40(1):34-42. PubMed ID: 26526959
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The use of a numerical model to simulate the cavo-pulmonary assistance in Fontan circulation: a preliminary verification.
    Di Molfetta A; Amodeo A; Fresiello L; Filippelli S; Pilati M; Iacobelli R; Adorisio R; Colella D; Ferrari G
    J Artif Organs; 2016 Jun; 19(2):105-13. PubMed ID: 26545595
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of Ventricular Assist Device in Univentricular Physiology: The Role of Lumped Parameter Models.
    Di Molfetta A; Ferrari G; Filippelli S; Fresiello L; Iacobelli R; Gagliardi MG; Amodeo A
    Artif Organs; 2016 May; 40(5):444-53. PubMed ID: 26494529
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Coupling pediatric ventricle assist devices to the Fontan circulation: simulations with a lumped-parameter model.
    Pekkan K; Frakes D; De Zelicourt D; Lucas CW; Parks WJ; Yoganathan AP
    ASAIO J; 2005; 51(5):618-28. PubMed ID: 16322728
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Single-Institutional Experience with 36 Children Smaller Than 5 Kilograms Supported with the Berlin Heart Ventricular Assist Device (VAD) over 12 Years: Comparison of Patients with Biventricular versus Functionally Univentricular Circulation.
    Bleiweis MS; Philip J; Peek GJ; Stukov Y; Janelle GM; Pitkin AD; Sullivan KJ; Nixon CS; Sharaf OM; Neal D; Jacobs JP
    World J Pediatr Congenit Heart Surg; 2023 Mar; 14(2):117-124. PubMed ID: 36798022
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Support with Single Ventricle-Ventricular Assist Device (sVAD) in Patients with Functionally Univentricular Circulation Prior to Fontan Operation.
    Bleiweis MS; Philip J; Fudge JC; Vyas HV; Peek GJ; Pitkin AD; Janelle GM; Sullivan KJ; Stukov Y; Nixon CS; Sharaf OM; Neal D; Jacobs JP
    Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu; 2023; 26():26-39. PubMed ID: 36842796
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Switching the Left and the Right Hearts: A Novel Bi-ventricle Mechanical Support Strategy with Spared Native Single-Ventricle.
    Şişli E; Yıldırım C; Aka İB; Tuncer ON; Atay Y; Özbaran M; Pekkan K
    Ann Biomed Eng; 2023 Dec; 51(12):2853-2872. PubMed ID: 37635154
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improving arterial pulsatility by feedback control of a continuous flow left ventricular assist device via in silico modeling.
    Bozkurt S; van de Vosse FN; Rutten MC
    Int J Artif Organs; 2014 Oct; 37(10):773-85. PubMed ID: 24970558
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis.
    Scardulla F; Agnese V; Romano G; Di Gesaro G; Sciacca S; Bellavia D; Clemenza F; Pilato M; Pasta S
    Cardiovasc Eng Technol; 2018 Sep; 9(3):427-437. PubMed ID: 29700783
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Exercise physiology with a left ventricular assist device: Analysis of heart-pump interaction with a computational simulator.
    Fresiello L; Rademakers F; Claus P; Ferrari G; Di Molfetta A; Meyns B
    PLoS One; 2017; 12(7):e0181879. PubMed ID: 28738087
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of 82 Children Supported With Pulsatile Paracorporeal Ventricular Assist Device: Comparison of Patients With Biventricular Versus Univentricular Circulation.
    Bleiweis MS; Stukov Y; Philip J; Peek GJ; Pitkin AD; Sullivan KJ; Neal D; Jacobs JP
    Semin Thorac Cardiovasc Surg; 2023; 35(2):367-376. PubMed ID: 35584776
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Control of a Pediatric Pulsatile Ventricular Assist Device: A Hybrid Cardiovascular Model Study.
    Ferrari G; Di Molfetta A; Zieliński K; Fresiello L; Górczyńska K; Pałko KJ; Darowski M; Amodeo A; Kozarski M
    Artif Organs; 2017 Dec; 41(12):1099-1108. PubMed ID: 28621816
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro evaluation of an external compression device for fontan mechanical assistance.
    Valdovinos J; Shkolyar E; Carman GP; Levi DS
    Artif Organs; 2014 Mar; 38(3):199-207. PubMed ID: 24147904
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The impact of prolonged rotary ventricular assist device support upon ventricular geometry and flow kinetics.
    Weiss RM; Kerber RE; Goerbig-Campbell JL; Davis MK; Cabuay BM; Ashrith G; Karrowni W; Davis JE; Johnson FL
    J Am Soc Echocardiogr; 2011 Feb; 24(2):149-56. PubMed ID: 21093217
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Designing an Active Valvulated Outflow Conduit for a Continuous-Flow Left Ventricular Assist Device to Increase Pulsatility: A Simulation Study.
    Cusimano V; Di Molfetta A; Ferrari G
    ASAIO J; 2021 May; 67(5):529-535. PubMed ID: 33902101
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simulation of acute haemodynamic outcomes of the surgical strategies for the right ventricular failure treatment in pediatric LVAD.
    Di Molfetta A; Ferrari G; Iacobelli R; Filippelli S; Fresiello L; Gagliardi MG; Toscano A; Trivella MG; Amodeo A
    Int J Artif Organs; 2015 Dec; 38(12):638-45. PubMed ID: 26847500
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.