These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

256 related articles for article (PubMed ID: 28228313)

  • 1. Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size.
    Mohan JC; Mohan V; Shukla M; Sethi A
    Indian Heart J; 2017; 69(1):87-92. PubMed ID: 28228313
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
    Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
    J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stented bioprosthetic valve hemodynamics: is the supra-annular implant better than the intra-annular?
    Badano LP; Pavoni D; Musumeci S; Frassani R; Gianfagna P; Baldassi M; Tursi V; Mazzaro E; Zakja E; Fioretti PM; Livi U
    J Heart Valve Dis; 2006 Mar; 15(2):238-46. PubMed ID: 16607907
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis.
    Bleiziffer S; Eichinger WB; Wagner I; Guenzinger R; Bauernschmitt R; Lange R
    J Heart Valve Dis; 2005 Nov; 14(6):814-21; discussion 821. PubMed ID: 16359064
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of early hemodynamic performance of 3 aortic valve bioprostheses.
    Ugur M; Suri RM; Daly RC; Dearani JA; Park SJ; Joyce LD; Burkhart HM; Greason KL; Schaff HV
    J Thorac Cardiovasc Surg; 2014 Nov; 148(5):1940-6. PubMed ID: 24530199
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemodynamic comparison of bioprostheses for complete supra-annular position in patients with small aortic annulus.
    Botzenhardt F; Eichinger WB; Bleiziffer S; Guenzinger R; Wagner IM; Bauernschmitt R; Lange R
    J Am Coll Cardiol; 2005 Jun; 45(12):2054-60. PubMed ID: 15963409
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The new St Jude Trifecta versus Carpentier-Edwards Perimount Magna and Magna Ease aortic bioprosthesis: is there a hemodynamic superiority?
    Wendt D; Thielmann M; Plicht B; Aßmann J; Price V; Neuhäuser M; Jakob H
    J Thorac Cardiovasc Surg; 2014 May; 147(5):1553-60. PubMed ID: 23870159
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hemodynamic performance of the Medtronic Mosaic and Perimount Magna aortic bioprostheses: five-year results of a prospectively randomized study.
    Dalmau MJ; González-Santos JM; Blázquez JA; Sastre JA; López-Rodríguez J; Bueno M; Castaño M; Arribas A
    Eur J Cardiothorac Surg; 2011 Jun; 39(6):844-52; discussion 852. PubMed ID: 21193320
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Do differences in early hemodynamic performance of current generation biologic aortic valves predict outcomes 1 year following surgery?
    Thalji NM; Suri RM; Michelena HI; Greason KL; Dearani JA; Daly RC; Joyce LD; Stulak JM; Burkhart HM; Li Z; Schaff HV
    J Thorac Cardiovasc Surg; 2015 Jan; 149(1):163-73.e2. PubMed ID: 25439772
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Early haemodynamic performance of a latest generation supra-annular aortic bioprosthesis: experience from a large single-centre series.
    Deutsch MA; Prinzing A; Fiegl K; Wottke M; Badiu CC; Krane M; Goppel G; Bleiziffer S; Guenzinger R; Lange R
    Eur J Cardiothorac Surg; 2016 Jun; 49(6):1691-8. PubMed ID: 26656235
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stentless vs Stented Aortic Valve Bioprostheses in the Small Aortic Root.
    Wollersheim LW; Li WW; Kaya A; Bouma BJ; Driessen AH; van Boven WJ; van der Meulen J; de Mol BA
    Semin Thorac Cardiovasc Surg; 2016 Summer; 28(2):390-397. PubMed ID: 28043449
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Suture technique does not affect hemodynamic performance of the small supra-annular Trifecta bioprosthesis.
    Ugur M; Byrne JG; Bavaria JE; Cheung A; Petracek M; Groh MA; Suri RM; Borger MA; Schaff HV
    J Thorac Cardiovasc Surg; 2014 Oct; 148(4):1347-51. PubMed ID: 24518226
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro assessment of heart valve bioprostheses by cardiovascular magnetic resonance: four-dimensional mapping of flow patterns and orifice area planimetry.
    von Knobelsdorff-Brenkenhoff F; Dieringer MA; Greiser A; Schulz-Menger J
    Eur J Cardiothorac Surg; 2011 Sep; 40(3):736-42. PubMed ID: 21342775
    [TBL] [Abstract][Full Text] [Related]  

  • 14. First ex vivo and preliminary sheep model results of the new TRIBIO aortic valve bioprosthesis in small aortic annuli.
    Stock S; Sievers HH; Richardt D; Scharfschwerdt M
    Interact Cardiovasc Thorac Surg; 2017 Nov; 25(5):793-798. PubMed ID: 28637199
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effective orifice area/patient aortic annulus area ratio: a better way to compare different bioprostheses? A prospective randomized comparison of the Mosaic and Perimount bioprostheses in the aortic position.
    Eichinger WB; Botzenhardt F; Guenzinger R; Bleiziffer S; Keithahn A; Bauernschmitt R; Lange R
    J Heart Valve Dis; 2004 May; 13(3):382-8; discussion 388-9. PubMed ID: 15222284
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the Carpentier-Edwards Perimount and St. Jude Medical Epic bioprostheses for aortic valve replacement--a retrospective echocardiographic short-term study.
    Goetzenich A; Langebartels G; Christiansen S; Hatam N; Autschbach R; Dohmen G
    J Card Surg; 2009; 24(3):260-4. PubMed ID: 19438778
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Differences in performance of five types of aortic valve prostheses: haemodynamic assessment by dobutamine stress echocardiography.
    Khoo JP; Davies JE; Ang KL; Galiñanes M; Chin DT
    Heart; 2013 Jan; 99(1):41-7. PubMed ID: 22895641
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.
    Nishioka N; Yamada A; Ujihira K; Iba Y; Maruyama R; Hatta E; Kurimoto Y; Nakanishi K
    Gen Thorac Cardiovasc Surg; 2016 Dec; 64(12):728-734. PubMed ID: 27491542
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study.
    Tasca G; Stefano A; Giannico F; Lobiati E; Riva B; Galanti A; Triggiani M; Gamba A
    J Heart Valve Dis; 2014 Sep; 23(5):633-41. PubMed ID: 25799714
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rigorous patient-prosthesis matching of Perimount Magna aortic bioprosthesis.
    Nakamura H; Yamaguchi H; Takagaki M; Kadowaki T; Nakao T; Amano A
    Asian Cardiovasc Thorac Ann; 2015 Mar; 23(3):261-6. PubMed ID: 25033914
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.