263 related articles for article (PubMed ID: 28233604)
1. Effects of Suture and Tourniquet on Intraoperative Kinematics in Navigated Total Knee Arthroplasty.
Tsubosaka M; Ishida K; Sasaki H; Shibanuma N; Kuroda R; Matsumoto T
J Arthroplasty; 2017 Jun; 32(6):1824-1828. PubMed ID: 28233604
[TBL] [Abstract][Full Text] [Related]
2. Navigation-based tibial rotation at 90° of flexion is associated with better range of motion in navigated total knee arthroplasty.
Ishida K; Shibanuma N; Matsumoto T; Sasaki H; Takayama K; Hiroshima Y; Kuroda R; Kurosaka M
Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2447-52. PubMed ID: 26846657
[TBL] [Abstract][Full Text] [Related]
3. Intraoperative posterior movement of the tibia at 90° of flexion predicts worse postoperative flexion angles in cruciate-substituting total knee arthroplasty.
Inokuchi T; Ishida K; Takayama K; Shibanuma N; Hayashi S; Kurosaka M; Kuroda R; Matsumoto T
Knee Surg Sports Traumatol Arthrosc; 2020 Sep; 28(9):2816-2822. PubMed ID: 31324963
[TBL] [Abstract][Full Text] [Related]
4. Posterior Reference Position Affects Intraoperative Kinematic and Soft Tissue Balance in Navigated Posterior-Stabilized Total Knee Arthroplasty.
Ishida K; Shibanuma N; Takayama K; Kurosaka M; Kuroda R; Matsumoto T
J Arthroplasty; 2018 Sep; 33(9):2851-2857. PubMed ID: 29805103
[TBL] [Abstract][Full Text] [Related]
5. Intraoperative joint gaps and mediolateral balance affect postoperative knee kinematics in posterior-stabilized total knee arthroplasty.
Watanabe T; Muneta T; Sekiya I; Banks SA
Knee; 2015 Dec; 22(6):527-34. PubMed ID: 26014342
[TBL] [Abstract][Full Text] [Related]
6. Tibiofemoral rotational alignment affects flexion angles in navigated posterior-stabilized total knee arthroplasty.
Ishida K; Shibanuma N; Matsumoto T; Toda A; Oka S; Kodato K; Takayama K; Kurosaka M; Kuroda R
Knee Surg Sports Traumatol Arthrosc; 2018 May; 26(5):1532-1539. PubMed ID: 28439637
[TBL] [Abstract][Full Text] [Related]
7. Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty.
Ishida K; Shibanuma N; Matsumoto T; Sasaki H; Takayama K; Toda A; Kuroda R; Kurosaka M
Knee Surg Sports Traumatol Arthrosc; 2015 Jun; 23(6):1741-7. PubMed ID: 25763851
[TBL] [Abstract][Full Text] [Related]
8. The Relationship between Soft-Tissue Balance and Intraoperative Kinematics of Guided Motion Total Knee Arthroplasty.
Inui H; Taketomi S; Yamagami R; Shirakawa N; Kawaguchi K; Tanaka S
J Knee Surg; 2019 Jan; 32(1):91-96. PubMed ID: 29514366
[TBL] [Abstract][Full Text] [Related]
9. Mid-flexion stability in the anteroposterior plane is achieved with a medial congruent insert in cruciate-retaining total knee arthroplasty for varus osteoarthritis.
Tsubosaka M; Ishida K; Kodato K; Shibanuma N; Hayashi S; Kurosaka M; Kuroda R; Matsumoto T
Knee Surg Sports Traumatol Arthrosc; 2021 Feb; 29(2):467-473. PubMed ID: 32157363
[TBL] [Abstract][Full Text] [Related]
10. Association of knee flexion angle after posterior-stabilized total knee arthroplasty with postoperative tibial external position relative to the femur and the extent of tibial internal rotation from knee extension to flexion.
Hanada M; Hotta K; Furuhashi H; Koyama H; Matsuyama Y
Knee; 2020 Oct; 27(5):1467-1475. PubMed ID: 33010763
[TBL] [Abstract][Full Text] [Related]
11. Medial knee stability at flexion increases tibial internal rotation and knee flexion angle after posterior-stabilized total knee arthroplasty.
Kamenaga T; Takayama K; Ishida K; Muratsu H; Hayashi S; Hashimoto S; Kuroda Y; Tsubosaka M; Takashima Y; Matsushita T; Niikura T; Kuroda R; Matsumoto T
Clin Biomech (Bristol, Avon); 2019 Aug; 68():16-22. PubMed ID: 31141758
[TBL] [Abstract][Full Text] [Related]
12. Comparison of in vivo knee kinematics before and after bicruciate-stabilized total knee arthroplasty during squatting.
Kiyohara M; Hamai S; Gondo H; Higaki H; Ikebe S; Okazaki K; Nakashima Y
BMC Musculoskelet Disord; 2021 Sep; 22(1):772. PubMed ID: 34511113
[TBL] [Abstract][Full Text] [Related]
13. Navigation-based femorotibial rotation pattern correlated with flexion angle after total knee arthroplasty.
Ishida K; Shibanuma N; Matsumoto T; Sasaki H; Takayama K; Matsuzaki T; Tei K; Kuroda R; Kurosaka M
Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):89-95. PubMed ID: 25261225
[TBL] [Abstract][Full Text] [Related]
14. Precision of Ci-navigated extension and flexion gap balancing in total knee arthroplasty and analysis of potential predictive variables.
Fickert S; Jawhar A; Sunil P; Scharf HP
Arch Orthop Trauma Surg; 2012 Apr; 132(4):565-74. PubMed ID: 22072193
[TBL] [Abstract][Full Text] [Related]
15. Lower Limb Anatomy and Alignment Affect Natural Tibiofemoral Knee Kinematics: A Cadaveric Investigation.
Maderbacher G; Baier C; Springorum HR; Zeman F; Grifka J; Keshmiri A
J Arthroplasty; 2016 Sep; 31(9):2038-42. PubMed ID: 27017201
[TBL] [Abstract][Full Text] [Related]
16. Three-dimensional tibiofemoral articular contact kinematics of a cruciate-retaining total knee arthroplasty.
Li G; Suggs J; Hanson G; Durbhakula S; Johnson T; Freiberg A
J Bone Joint Surg Am; 2006 Feb; 88(2):395-402. PubMed ID: 16452753
[TBL] [Abstract][Full Text] [Related]
17. Intraoperative kinematics of bicruciate-stabilized total knee arthroplasty during high-flexion motion of the knee.
Kono K; Inui H; Taketomi S; Yamagami R; Kawaguchi K; Sameshima S; Kage T; Tanaka S
Knee; 2021 Mar; 29():291-297. PubMed ID: 33677153
[TBL] [Abstract][Full Text] [Related]
18. Influence of Medial Collateral Ligament Release for Internal Rotation of Tibia in Posterior-Stabilized Total Knee Arthroplasty: A Cadaveric Study.
Wada K; Hamada D; Tamaki S; Higashino K; Fukui Y; Sairyo K
J Arthroplasty; 2017 Jan; 32(1):270-273. PubMed ID: 27460300
[TBL] [Abstract][Full Text] [Related]
19. Tourniquet does not affect intraoperative kinematics during total knee arthroplasty: Results of a prospective study using a robotic assistance system.
Faschingbauer M; Freisem K; Khury F; Martin RJ; Bieger R; Reichel H
Knee Surg Sports Traumatol Arthrosc; 2024 Mar; 32(3):678-684. PubMed ID: 38410061
[TBL] [Abstract][Full Text] [Related]
20. Gap measurement in posterior-stabilized total knee arthroplasty with or without a trial femoral component.
Hayashi S; Murakami Y; Inoue H; Nobutou H; Nishida K; Mochizuki Y
Arch Orthop Trauma Surg; 2014 Jun; 134(6):861-5. PubMed ID: 24519710
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]