646 related articles for article (PubMed ID: 28233729)
1. Outcome of distal end clavicle fractures treated with locking plates.
Vaishya R; Vijay V; Khanna V
Chin J Traumatol; 2017 Feb; 20(1):45-48. PubMed ID: 28233729
[TBL] [Abstract][Full Text] [Related]
2. Comparative analysis of functional outcome of anatomical precontoured locking plate versus reconstruction plate in the management of displaced midshaft clavicular fractures.
Kingsly P; Sathish M; Ismail NDM
J Orthop Surg (Hong Kong); 2019; 27(1):2309499018820351. PubMed ID: 30798707
[TBL] [Abstract][Full Text] [Related]
3. Angular stable fixation of displaced distal-third clavicle fractures with superior precontoured locking plates.
Fleming MA; Dachs R; Maqungo S; du Plessis JP; Vrettos BC; Roche SJ
J Shoulder Elbow Surg; 2015 May; 24(5):700-4. PubMed ID: 25457780
[TBL] [Abstract][Full Text] [Related]
4. Complications after surgical treatment of distal clavicle fractures.
Singh A; Schultzel M; Fleming JF; Navarro RA
Orthop Traumatol Surg Res; 2019 Sep; 105(5):853-859. PubMed ID: 31202717
[TBL] [Abstract][Full Text] [Related]
5. Precontoured locking plate fixation for displaced lateral clavicle fractures.
Lee SK; Lee JW; Song DG; Choy WS
Orthopedics; 2013 Jun; 36(6):801-7. PubMed ID: 23746019
[TBL] [Abstract][Full Text] [Related]
6. Precontoured Locking Compression Plate with Titanium Alloy Cable System: In Treatment of Neer Type IIb Distal Clavicle Fracture.
Xie Z; Song M; Zhou J; Yin G; Lin H
Orthop Surg; 2021 Apr; 13(2):451-457. PubMed ID: 33480180
[TBL] [Abstract][Full Text] [Related]
7. Return to sports after plate fixation of displaced midshaft clavicular fractures in athletes.
Ranalletta M; Rossi LA; Piuzzi NS; Bertona A; Bongiovanni SL; Maignon G
Am J Sports Med; 2015 Mar; 43(3):565-9. PubMed ID: 25492034
[TBL] [Abstract][Full Text] [Related]
8. Management of unstable distal third clavicle fractures: clinical and radiological outcomes of the arthroscopy-assisted conoid ligament reconstruction and fracture cerclage with sutures.
Cisneros LN; Reiriz JS
Eur J Orthop Surg Traumatol; 2017 Apr; 27(3):373-380. PubMed ID: 28229229
[TBL] [Abstract][Full Text] [Related]
9. Comparative Analysis of Clavicular Hook Plate Versus Distal Radius Volar Plate With Coracoclavicular Augmentation for Neer's Type 2b Lateral Clavicle Fractures: A Prospective Study.
Bandebuche AR; Rai AK; Bansal D; Gupta D; Naidu A
Cureus; 2022 Mar; 14(3):e22969. PubMed ID: 35415023
[TBL] [Abstract][Full Text] [Related]
10. Displaced medial end clavicular fractures treated with an inverted distal clavicle plate contoured through 90 degrees.
Titchener A; See A; Van Rensburg L; Tytherleigh-Strong G
J Shoulder Elbow Surg; 2019 Apr; 28(4):e97-e103. PubMed ID: 30454930
[TBL] [Abstract][Full Text] [Related]
11. [Treatment of fresh tossy type III acromioclavicular joint dislocations and neer type II distal clavicle fractures with clavicular hook plate].
Tan H; Wang S; Zhao J; Qian C; Zhou Q; Shi Y
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 Jan; 24(1):69-73. PubMed ID: 20135976
[TBL] [Abstract][Full Text] [Related]
12. Displaced Medial-End Clavicle Fractures Treated with Locking Plate Osteosynthesis.
Liu Z; Zhang J; Tian X; Kan S
Med Sci Monit; 2019 Oct; 25():7591-7596. PubMed ID: 31596837
[TBL] [Abstract][Full Text] [Related]
13. Comparison of hook plate versus T-plate in the treatment of Neer type II distal clavicle fractures: a prospective matched comparative cohort study.
Teimouri M; Ravanbod H; Farrokhzad A; Sabaghi J; Mirghaderi SP
J Orthop Surg Res; 2022 Jul; 17(1):369. PubMed ID: 35907856
[TBL] [Abstract][Full Text] [Related]
14. Use of plate fixation without coracoclavicular ligament augmentation for unstable distal clavicle fractures.
Shin SJ; Ko YW; Lee J; Park MG
J Shoulder Elbow Surg; 2016 Jun; 25(6):942-8. PubMed ID: 26711474
[TBL] [Abstract][Full Text] [Related]
15. Clavicle hook plate fixation for distal-third clavicle fracture (Neer type II): comparison of clinical and radiologic outcomes between Neer types IIA and IIB.
Lee W; Choi CH; Choi YR; Lim KH; Chun YM
J Shoulder Elbow Surg; 2017 Jul; 26(7):1210-1215. PubMed ID: 28131682
[TBL] [Abstract][Full Text] [Related]
16. Hook versus locking plate fixation for Neer type-II and type-V distal clavicle fractures: a retrospective cohort study.
Chen MJ; DeBaun MR; Salazar BP; Lai C; Bishop JA; Gardner MJ
Eur J Orthop Surg Traumatol; 2020 Aug; 30(6):1027-1031. PubMed ID: 32221679
[TBL] [Abstract][Full Text] [Related]
17. Comparing hook plates and Kirschner tension band wiring for unstable lateral clavicle fractures.
Wu K; Chang CH; Yang RS
Orthopedics; 2011 Nov; 34(11):e718-23. PubMed ID: 22049952
[TBL] [Abstract][Full Text] [Related]
18. Clinical results of treatment using a clavicular hook plate versus a T-plate in neer type II distal clavicle fractures.
Tan HL; Zhao JK; Qian C; Shi Y; Zhou Q
Orthopedics; 2012 Aug; 35(8):e1191-7. PubMed ID: 22868604
[TBL] [Abstract][Full Text] [Related]
19. Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle.
Collinge C; Devinney S; Herscovici D; DiPasquale T; Sanders R
J Orthop Trauma; 2006; 20(10):680-6. PubMed ID: 17106378
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical Analysis of Superior and Anterior Precontoured Plate Fixation Techniques for Neer Type II-A Clavicle Fractures.
Worhacz K; Nayak AN; Boudreaux RL; Pavan B; Wipf Dipl-Ing F; Jacofsky MC; Araghi A
J Orthop Trauma; 2018 Dec; 32(12):e462-e468. PubMed ID: 30252778
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]