These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
162 related articles for article (PubMed ID: 28247658)
1. [Comparative evaluation of the efficacy of uncoated and coated with silver silicone urethral catheters for prevention of urinary tract infections among patients of the intensive care unit]. Sergevnin VI; Klyuchareva NM; Antipin DP; Laricheva EN Urologiia; 2016 Apr; (2):33-36. PubMed ID: 28247658 [TBL] [Abstract][Full Text] [Related]
2. A prospective trial of a novel, silicone-based, silver-coated foley catheter for the prevention of nosocomial urinary tract infections. Srinivasan A; Karchmer T; Richards A; Song X; Perl TM Infect Control Hosp Epidemiol; 2006 Jan; 27(1):38-43. PubMed ID: 16418985 [TBL] [Abstract][Full Text] [Related]
4. Types of urethral catheters for management of short-term voiding problems in hospitalized adults: a short version Cochrane review. Schumm K; Lam TB Neurourol Urodyn; 2008; 27(8):738-46. PubMed ID: 18951451 [TBL] [Abstract][Full Text] [Related]
5. A randomized controlled trial to assess the efficacy and cost-effectiveness of urinary catheters with silver alloy coating in spinal cord injured patients: trial protocol. Bonfill X; Rigau D; Jáuregui-Abrisqueta ML; Barrera Chacón JM; de la Barrera SS; Alemán-Sánchez CM; Bea-Muñoz M; Moraleda Pérez S; Borau Duran A; Espinosa Quirós JR; Ledesma Romano L; Fuertes ME; Araya I; Martínez-Zapata MJ BMC Urol; 2013 Jul; 13():38. PubMed ID: 23895463 [TBL] [Abstract][Full Text] [Related]
7. Restriction of in vivo infection by antifouling coating on urinary catheter with controllable and sustained silver release: a proof of concept study. Mandakhalikar KD; Wang R; Rahmat JN; Chiong E; Neoh KG; Tambyah PA BMC Infect Dis; 2018 Aug; 18(1):370. PubMed ID: 30081836 [TBL] [Abstract][Full Text] [Related]
8. A randomized clinical trial comparing Nitrofurazone-coated and uncoated urinary catheters in kidney transplant recipients: Results from a pilot study. Menezes FG; Corrêa L; Medina-Pestana JO; Aguiar WF; Camargo LFA Transpl Infect Dis; 2019 Apr; 21(2):e13031. PubMed ID: 30451342 [TBL] [Abstract][Full Text] [Related]
9. Catheter-associated urinary tract infections and other infections in patients hospitalized for acute stroke: A prospective cohort study of two different silicone catheters. Stenzelius K; Laszlo L; Madeja M; Pessah-Rasmusson H; Grabe M Scand J Urol; 2016 Dec; 50(6):483-488. PubMed ID: 27328334 [TBL] [Abstract][Full Text] [Related]
10. An investigation of the effectiveness against bacteriuria of silver-coated catheters in short-term urinary catheter applications: A randomized controlled study. Akcam FZ; Kaya O; Temel EN; Buyuktuna SA; Unal O; Yurekli VA J Infect Chemother; 2019 Oct; 25(10):797-800. PubMed ID: 31030965 [TBL] [Abstract][Full Text] [Related]
11. Audit of catheter-associated UTI using silver alloy-coated Foley catheters. Seymour C Br J Nurs; 2006 Jun 8-21; 15(11):598-603. PubMed ID: 16835528 [TBL] [Abstract][Full Text] [Related]
12. Antifouling coating with controllable and sustained silver release for long-term inhibition of infection and encrustation in urinary catheters. Wang R; Neoh KG; Kang ET; Tambyah PA; Chiong E J Biomed Mater Res B Appl Biomater; 2015 Apr; 103(3):519-28. PubMed ID: 24922113 [TBL] [Abstract][Full Text] [Related]
13. Catheter induced urethral inflammatory reaction and urinary tract infection. An experimental and clinical study. Liedberg H Scand J Urol Nephrol Suppl; 1989; 124():1-43. PubMed ID: 2633310 [TBL] [Abstract][Full Text] [Related]
14. Effects of the use of silver-coated urinary catheters on the incidence of catheter-associated bacteriuria and urinary tract infection in dogs. Ogilvie AT; Brisson BA; Gow WR; Wainberg S; Singh A; Weese JS J Am Vet Med Assoc; 2018 Nov; 253(10):1289-1293. PubMed ID: 30398417 [TBL] [Abstract][Full Text] [Related]
15. Randomized multi-centre trial of the effects of a catheter coated with hydrogel and silver salts on the incidence of hospital-acquired urinary tract infections. Thibon P; Le Coutour X; Leroyer R; Fabry J J Hosp Infect; 2000 Jun; 45(2):117-24. PubMed ID: 10860688 [TBL] [Abstract][Full Text] [Related]
16. [A controlled trial of a new material for coating urinary catheters]. Chene G; Boulard G; Gachie JP Agressologie; 1990; 31(8 Spec No):499-501. PubMed ID: 2089969 [TBL] [Abstract][Full Text] [Related]
17. Noble metal alloy-coated latex versus silicone Foley catheter in short-term catheterization: a randomized controlled study. Stenzelius K; Persson S; Olsson UB; Stjärneblad M Scand J Urol Nephrol; 2011 Sep; 45(4):258-64. PubMed ID: 21452931 [TBL] [Abstract][Full Text] [Related]
19. In vitro evaluation of the efficacy of a silver-coated catheter. Gabriel MM; Mayo MS; May LL; Simmons RB; Ahearn DG Curr Microbiol; 1996 Jul; 33(1):1-5. PubMed ID: 8661684 [TBL] [Abstract][Full Text] [Related]
20. Intermittent catheterisation with hydrophilic-coated catheters (SpeediCath) reduces the risk of clinical urinary tract infection in spinal cord injured patients: a prospective randomised parallel comparative trial. De Ridder DJ; Everaert K; Fernández LG; Valero JV; Durán AB; Abrisqueta ML; Ventura MG; Sotillo AR Eur Urol; 2005 Dec; 48(6):991-5. PubMed ID: 16137822 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]