These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

201 related articles for article (PubMed ID: 28249493)

  • 1. All-digital pulse-expansion-based CMOS digital-to-time converter.
    Chen CC; Chu CH
    Rev Sci Instrum; 2017 Feb; 88(2):024704. PubMed ID: 28249493
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CMOS time-to-digital converter based on a pulse-mixing scheme.
    Chen CC; Hwang CS; Liu KC; Chen GH
    Rev Sci Instrum; 2014 Nov; 85(11):114702. PubMed ID: 25430128
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A 13-Bit, 12-ps Resolution Vernier Time-to-Digital Converter Based on Dual Delay-Rings for SPAD Image Sensor.
    Huang Z; Huang J; Tian L; Wang N; Zhu Y; Wang H; Feng S
    Sensors (Basel); 2021 Jan; 21(3):. PubMed ID: 33499338
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Area-efficient all-digital pulse-shrinking smart temperature sensor with improved accuracy and resolution.
    Chen CC; Hwang CS; Chu CS
    Rev Sci Instrum; 2018 Dec; 89(12):125002. PubMed ID: 30599587
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Low-Power Gateable Vernier Ring Oscillator Time-to-Digital Converter for Biomedical Imaging Applications.
    Cheng Z; Deen MJ; Peng H
    IEEE Trans Biomed Circuits Syst; 2016 Apr; 10(2):445-54. PubMed ID: 26168446
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Note: All-digital CMOS MOS-capacitor-based pulse-shrinking mechanism suitable for time-to-digital converters.
    Chen CC; Hwang CS; Lin YT; Liu KC
    Rev Sci Instrum; 2015 Dec; 86(12):126113. PubMed ID: 26724094
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A 12-bit high-speed column-parallel two-step single-slope analog-to-digital converter (ADC) for CMOS image sensors.
    Lyu T; Yao S; Nie K; Xu J
    Sensors (Basel); 2014 Nov; 14(11):21603-25. PubMed ID: 25407903
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Design of a Single-Bit CMOS Image Sensor for Iris Recognition Applications.
    Park K; Song M; Kim SY
    Sensors (Basel); 2018 Feb; 18(2):. PubMed ID: 29495273
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-Linearity High-Resolution Time-of-Flight Linear-Array Digital Image Sensor Using Time-Domain Feedback.
    Kim J; Yasutomi K; Kagawa K; Kawahito S
    Sensors (Basel); 2021 Jan; 21(2):. PubMed ID: 33440663
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reconfigurable Sensor Analog Front-End Using Low-Noise Chopper-Stabilized Delta-Sigma Capacitance-to-Digital Converter.
    Kim H; Lee B; Mun Y; Kim J; Han K; Roh Y; Song D; Huh S; Ko H
    Micromachines (Basel); 2018 Jul; 9(7):. PubMed ID: 30424280
    [TBL] [Abstract][Full Text] [Related]  

  • 11. CMOS Ultrasound Transceiver Chip for High-Resolution Ultrasonic Imaging Systems.
    Insoo Kim ; Hyunsoo Kim ; Griggio F; Tutwiler RL; Jackson TN; Trolier-McKinstry S; Kyusun Choi
    IEEE Trans Biomed Circuits Syst; 2009 Oct; 3(5):293-303. PubMed ID: 23853268
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Low Noise CMOS Readout Based on a Polymer-Coated SAW Array for Miniature Electronic Nose.
    Wu CC; Liu SC; Chiu SW; Tang KT
    Sensors (Basel); 2016 Oct; 16(11):. PubMed ID: 27792131
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design of an Always-On Image Sensor Using an Analog Lightweight Convolutional Neural Network.
    Choi J; Lee S; Son Y; Kim SY
    Sensors (Basel); 2020 May; 20(11):. PubMed ID: 32486271
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Design of a New Column-Parallel Analog-to-Digital Converter Flash for Monolithic Active Pixel Sensor.
    Chakir M; Akhamal H; Qjidaa H
    ScientificWorldJournal; 2017; 2017():8418042. PubMed ID: 28243628
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Multi-Resolution Mode CMOS Image Sensor with a Novel Two-Step Single-Slope ADC for Intelligent Surveillance Systems.
    Kim D; Song M; Choe B; Kim SY
    Sensors (Basel); 2017 Jun; 17(7):. PubMed ID: 28672832
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A 1.33 μW 8.02-ENOB 100 kS/s successive approximation ADC with supply reduction technique for implantable retinal prosthesis.
    Tang H; Sun ZC; Chew KW; Siek L
    IEEE Trans Biomed Circuits Syst; 2014 Dec; 8(6):844-56. PubMed ID: 25608284
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A PWM Buck Converter With Load-Adaptive Power Transistor Scaling Scheme Using Analog-Digital Hybrid Control for High Energy Efficiency in Implantable Biomedical Systems.
    Park SY; Cho J; Lee K; Yoon E
    IEEE Trans Biomed Circuits Syst; 2015 Dec; 9(6):885-95. PubMed ID: 26742139
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Low-Power All-Digital on-Chip CMOS Oscillator for a Wireless Sensor Node.
    Sheng D; Hong MR
    Sensors (Basel); 2016 Oct; 16(10):. PubMed ID: 27754439
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pulse-forming-line based on-chip short pulse generator.
    Zou H; Wang H
    Rev Sci Instrum; 2015 Apr; 86(4):044706. PubMed ID: 25933879
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design of a CMOS Image Sensor with Bi-Directional Gamma-Corrected Digital-Correlated Double Sampling.
    Cho J; Choo H; Lee S; Yoon S; Kam G; Kim S
    Sensors (Basel); 2023 Jan; 23(2):. PubMed ID: 36679827
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.