375 related articles for article (PubMed ID: 28257624)
1. Endotracheal tubes and fluid aspiration: an in vitro evaluation of new cuff technologies.
Mariyaselvam MZ; Marsh LL; Bamford S; Smith A; Wise MP; Williams DW
BMC Anesthesiol; 2017 Mar; 17(1):36. PubMed ID: 28257624
[TBL] [Abstract][Full Text] [Related]
2. Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs.
Chenelle CT; Itagaki T; Fisher DF; Berra L; Kacmarek RM
Respir Care; 2017 Jan; 62(1):102-112. PubMed ID: 27879379
[TBL] [Abstract][Full Text] [Related]
3. Influence of an endotracheal tube with polyurethane cuff and subglottic secretion drainage on pneumonia.
Lorente L; Lecuona M; Jiménez A; Mora ML; Sierra A
Am J Respir Crit Care Med; 2007 Dec; 176(11):1079-83. PubMed ID: 17872488
[TBL] [Abstract][Full Text] [Related]
4. Strategies to prevent ventilation-associated pneumonia: the effect of cuff pressure monitoring techniques and tracheal tube type on aspiration of subglottic secretions: an in-vitro study.
Carter EL; Duguid A; Ercole A; Matta B; Burnstein RM; Veenith T
Eur J Anaesthesiol; 2014 Mar; 31(3):166-71. PubMed ID: 24270899
[TBL] [Abstract][Full Text] [Related]
5. Comparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia.
Mahmoodpoor A; Peyrovi-far A; Hamishehkar H; Bakhtyiari Z; Mirinezhad MM; Hamidi M; Golzari SE
Acta Med Iran; 2013 Aug; 51(7):461-6. PubMed ID: 23945890
[TBL] [Abstract][Full Text] [Related]
6. Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: a bench-top study.
Zanella A; Scaravilli V; Isgrò S; Milan M; Cressoni M; Patroniti N; Fumagalli R; Pesenti A
Intensive Care Med; 2011 Feb; 37(2):343-7. PubMed ID: 21152894
[TBL] [Abstract][Full Text] [Related]
7. The value of polyurethane-cuffed endotracheal tubes to reduce microaspiration and intubation-related pneumonia: a systematic review of laboratory and clinical studies.
Blot SI; Rello J; Koulenti D
Crit Care; 2016 Jun; 20(1):203. PubMed ID: 27342802
[TBL] [Abstract][Full Text] [Related]
8. Endotracheal Tube Seal and Suction Performance in a Novel Biorealistic Tracheal Model.
Rozycki SK; Dixon FP; Yopp MA; Maxvold NJ; Rubin BK
Respir Care; 2015 Aug; 60(8):1113-9. PubMed ID: 25944945
[TBL] [Abstract][Full Text] [Related]
9. Variables affecting leakage past endotracheal tube cuffs: a bench study.
Pitts R; Fisher D; Sulemanji D; Kratohvil J; Jiang Y; Kacmarek R
Intensive Care Med; 2010 Dec; 36(12):2066-73. PubMed ID: 20852839
[TBL] [Abstract][Full Text] [Related]
10. Incidence of endotracheal tube colonization with the use of PneuX endotracheal tubes in patients following cardiac surgery.
Senanayake EL; Giri R; Gopal S; Nevill A; Luckraz H
J Hosp Infect; 2017 Jan; 95(1):81-86. PubMed ID: 27837930
[TBL] [Abstract][Full Text] [Related]
11. A double-layer tracheal tube cuff designed to prevent leakage: a bench-top study.
Zanella A; Cressoni M; Epp M; Stylianou M; Kolobow T
Intensive Care Med; 2008 Jun; 34(6):1145-9. PubMed ID: 18259729
[TBL] [Abstract][Full Text] [Related]
12. The impact of hospital-wide use of a tapered-cuff endotracheal tube on the incidence of ventilator-associated pneumonia.
Bowton DL; Hite RD; Martin RS; Sherertz R
Respir Care; 2013 Oct; 58(10):1582-7. PubMed ID: 23431308
[TBL] [Abstract][Full Text] [Related]
13. Endotracheal tubes: old and new.
Haas CF; Eakin RM; Konkle MA; Blank R
Respir Care; 2014 Jun; 59(6):933-52; discussion 952-5. PubMed ID: 24891200
[TBL] [Abstract][Full Text] [Related]
14. Randomized Pilot Trial of Two Modified Endotracheal Tubes To Prevent Ventilator-associated Pneumonia.
Deem S; Yanez D; Sissons-Ross L; Broeckel JA; Daniel S; Treggiari M
Ann Am Thorac Soc; 2016 Jan; 13(1):72-80. PubMed ID: 26523433
[TBL] [Abstract][Full Text] [Related]
15. An Artificial Cough Maneuver to Remove Secretions From Below the Endotracheal Tube Cuff.
Zanella A; Florio G; Rezoagli E; Pastore M; Cadringer P; Biancolilli O; Carlesso E; Scaravilli V; Ristagno G; Pesenti AM
Respir Care; 2019 Apr; 64(4):372-383. PubMed ID: 30622174
[TBL] [Abstract][Full Text] [Related]
16. The interaction of subglottic drainage, cuff pressure, and oral care on endotracheal tube fluid leakage: A benchtop study.
Chair SY; Chan DWK; Cao X
Aust Crit Care; 2020 Jul; 33(4):358-363. PubMed ID: 31248697
[TBL] [Abstract][Full Text] [Related]
17. Ventilator associated pneumonia: evolving definitions and preventive strategies.
Mietto C; Pinciroli R; Patel N; Berra L
Respir Care; 2013 Jun; 58(6):990-1007. PubMed ID: 23709196
[TBL] [Abstract][Full Text] [Related]
18. Insights on the role of antimicrobial cuffed endotracheal tubes in preventing transtracheal transmission of VAP pathogens from an in vitro model of microaspiration and microbial proliferation.
Rosenblatt J; Reitzel R; Jiang Y; Hachem R; Raad I
Biomed Res Int; 2014; 2014():120468. PubMed ID: 24818125
[TBL] [Abstract][Full Text] [Related]
19. Endotracheal tube and laryngeal mask airway cuff pressures can exceed critical values during ascent to higher altitude.
Miyashiro RM; Yamamoto LG
Pediatr Emerg Care; 2011 May; 27(5):367-70. PubMed ID: 21494168
[TBL] [Abstract][Full Text] [Related]
20. Prehospital Intubations Are Associated with Elevated Endotracheal Tube Cuff Pressures: A Cross-Sectional Study Characterizing ETT Cuff Pressures at a Tertiary Care Emergency Department.
Chen RS; O'Connor L; Rebesco MR; LaBarge KL; Remotti EJ; Tennyson JC
Prehosp Disaster Med; 2021 Jun; 36(3):283-286. PubMed ID: 33818359
[TBL] [Abstract][Full Text] [Related]