These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

411 related articles for article (PubMed ID: 28261978)

  • 41. Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses.
    Park SW; Chung MJ; Lee SH; Lee HS; Lee HJ; Park JY; Park SW; Song SY; Kim H; Chung JB; Bang S
    PLoS One; 2016; 11(5):e0154401. PubMed ID: 27149404
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Comparison of Ultrasound-Guided Core Needle Biopsy and Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Pancreatic Lesions.
    Sur YK; Kim YC; Kim JK; Lee JH; Yoo BM; Kim YB
    J Ultrasound Med; 2015 Dec; 34(12):2163-9. PubMed ID: 26491091
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A 19-Gauge Histology Needle Versus a 19-Gauge Standard Needle in Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Lesions: A Multicenter Randomized Comparison Study (GREATER Study).
    Iwashita T; Nakai Y; Mukai T; Togawa O; Matsubara S; Hatano Y; Hara A; Tanaka M; Shibahara J; Fukayama M; Isayama H; Yasuda I
    Dig Dis Sci; 2018 Apr; 63(4):1043-1051. PubMed ID: 29464585
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Randomized Trial Comparing the Flexible 19G and 25G Needles for Endoscopic Ultrasound-Guided Fine Needle Aspiration of Solid Pancreatic Mass Lesions.
    Ramesh J; Bang JY; Hebert-Magee S; Trevino J; Eltoum I; Frost A; Hasan MK; Logue A; Hawes R; Varadarajulu S
    Pancreas; 2015 Jan; 44(1):128-33. PubMed ID: 25232713
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Slow-pull and different conventional suction techniques in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid lesions using 22-gauge needles.
    Chen JY; Ding QY; Lv Y; Guo W; Zhi FC; Liu SD; Cheng TM
    World J Gastroenterol; 2016 Oct; 22(39):8790-8797. PubMed ID: 27818594
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Benefit of high negative pressure during endoscopic ultrasound-guided fine-needle aspiration with standard 22-gauge needles for pancreatic lesions: a retrospective comparative study.
    Sato J; Ishiwatari H; Sasaki K; Fujie S; Kaneko J; Satoh T; Matsubayashi H; Kishida Y; Yoshida M; Ito S; Kawata N; Imai K; Kakushima N; Takizawa K; Hotta K; Ono H
    Scand J Gastroenterol; 2019 Jan; 54(1):108-113. PubMed ID: 30676114
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Comparison of endoscopic ultrasound-guided fine-needle biopsy versus fine-needle aspiration for genomic profiling and DNA yield in pancreatic cancer: a randomized crossover trial.
    Kandel P; Nassar A; Gomez V; Raimondo M; Woodward TA; Crook JE; Fares NS; Wallace MB
    Endoscopy; 2021 Apr; 53(4):376-382. PubMed ID: 32767288
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Endoscopic ultrasound-guided fine-needle aspiration needles: which one and in what situation?
    Karadsheh Z; Al-Haddad M
    Gastrointest Endosc Clin N Am; 2014 Jan; 24(1):57-69. PubMed ID: 24215760
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study.
    Larghi A; Iglesias-Garcia J; Poley JW; Monges G; Petrone MC; Rindi G; Abdulkader I; Arcidiacono PG; Costamagna G; Biermann K; Bories E; Doglioni C; Dominguez-Muñoz JE; Hassan C; Bruno M; Giovannini M
    Surg Endosc; 2013 Oct; 27(10):3733-8. PubMed ID: 23644834
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Primary pancreatic leiomyosarcoma with metastasis to the liver diagnosed by endoscopic ultrasound-guided fine needle aspiration and fine needle biopsy: A Case Report and Review of Literature.
    Reyes MC; Huang X; Bain A; Ylagan L
    Diagn Cytopathol; 2016 Dec; 44(12):1070-1073. PubMed ID: 27455910
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Novel fork-tip needles versus standard needles for EUS-guided tissue acquisition from solid masses of the upper GI tract: a matched cohort study.
    Jovani M; Abidi WM; Lee LS
    Scand J Gastroenterol; 2017; 52(6-7):784-787. PubMed ID: 28355953
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses.
    Sakamoto H; Kitano M; Komaki T; Noda K; Chikugo T; Dote K; Takeyama Y; Das K; Yamao K; Kudo M
    J Gastroenterol Hepatol; 2009 Mar; 24(3):384-90. PubMed ID: 19032453
    [TBL] [Abstract][Full Text] [Related]  

  • 53. EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles.
    Siddiqui UD; Rossi F; Rosenthal LS; Padda MS; Murali-Dharan V; Aslanian HR
    Gastrointest Endosc; 2009 Dec; 70(6):1093-7. PubMed ID: 19640524
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparative accuracy of needle sizes and designs for EUS tissue sampling of solid pancreatic masses: a network meta-analysis.
    Facciorusso A; Wani S; Triantafyllou K; Tziatzios G; Cannizzaro R; Muscatiello N; Singh S
    Gastrointest Endosc; 2019 Dec; 90(6):893-903.e7. PubMed ID: 31310744
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Diagnostic yield of EUS-FNA of small (≤15 mm) solid pancreatic lesions using a 25-gauge needle.
    Crinò SF; Conti Bellocchi MC; Bernardoni L; Manfrin E; Parisi A; Amodio A; De Pretis N; Frulloni L; Gabbrielli A
    Hepatobiliary Pancreat Dis Int; 2018 Feb; 17(1):70-74. PubMed ID: 29428108
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The yield of cytology and histology obtained by endoscopic ultrasound-guided fine needle aspiration and biopsy needles in the diagnosis of pancreatic adenocarcinoma.
    Sbeit W; Abu Hanna N; Alejandro L; Khoury T
    Cytopathology; 2024 Jan; 35(1):92-97. PubMed ID: 37698128
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Cohort study comparing the diagnostic yields of 2 different EUS fine-needle biopsy needles.
    Abdelfatah MM; Grimm IS; Gangarosa LM; Baron TH
    Gastrointest Endosc; 2018 Feb; 87(2):495-500. PubMed ID: 28882575
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A prospective, randomized trial comparing 25-gauge and 22-gauge needles for endoscopic ultrasound-guided fine needle aspiration of pancreatic masses.
    Lee JK; Lee KT; Choi ER; Jang TH; Jang KT; Lee JK; Lee KH
    Scand J Gastroenterol; 2013 Jun; 48(6):752-7. PubMed ID: 23600919
    [TBL] [Abstract][Full Text] [Related]  

  • 59. IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
    Ardengh JC; Brunaldi VO; Brunaldi MO; Gaspar AF; Lopes-JÚnior JR; Sankarankutty AK; Kemp R; Santos JSD
    Arq Bras Cir Dig; 2021; 33(4):e1554. PubMed ID: 33503114
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Evaluation of 22G fine-needle aspiration (FNA) versus fine-needle biopsy (FNB) for endoscopic ultrasound-guided sampling of pancreatic lesions: a prospective comparison study.
    Tian L; Tang AL; Zhang L; Liu XW; Li JB; Wang F; Shen SR; Wang XY
    Surg Endosc; 2018 Aug; 32(8):3533-3539. PubMed ID: 29404729
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.