129 related articles for article (PubMed ID: 28269063)
21. Wireless platform for multi-channel analog measurements.
Heinisuo S; Vanhala J
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5908-11. PubMed ID: 17945918
[TBL] [Abstract][Full Text] [Related]
22. Event-Driven ECG Sensor in Healthcare Devices for Data Transfer Optimization.
Ben-Romdhane M; Maalej A; Tlili M; Rebai C; Rivet F; Dallet D
Arab J Sci Eng; 2020; 45(8):6361-6387. PubMed ID: 32421087
[TBL] [Abstract][Full Text] [Related]
23. Low-power signal processing devices for portable ECG detection.
Lee SY; Cheng CJ; Wang CP; Kao WC
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():1683-6. PubMed ID: 19163002
[TBL] [Abstract][Full Text] [Related]
24. [Development of a Wearable Wireless ECG Monitoring System with Ultra-low Power Consumption].
Sun Z; Ye J; Zhang X; Yuan M; Zhong Z; Tan X
Zhongguo Yi Liao Qi Xie Za Zhi; 2020 Jan; 44(1):28-32. PubMed ID: 32343062
[TBL] [Abstract][Full Text] [Related]
25. An ECG recording front-end with continuous-time level-crossing sampling.
Li Y; Mansano AL; Yuan Y; Zhao D; Serdijn WA
IEEE Trans Biomed Circuits Syst; 2014 Oct; 8(5):626-35. PubMed ID: 25330494
[TBL] [Abstract][Full Text] [Related]
26. A Low-Power High-Data-Transmission Multi-Lead ECG Acquisition Sensor System.
Wang LH; Zhang W; Guan MH; Jiang SY; Fan MH; Abu PAR; Chen CA; Chen SL
Sensors (Basel); 2019 Nov; 19(22):. PubMed ID: 31744095
[TBL] [Abstract][Full Text] [Related]
27. A 1.02 μW Battery-Less, Continuous Sensing and Post-Processing SiP for Wearable Applications.
Lukas CJ; Yahya FB; Breiholz J; Roy A; Chen X; Patel HN; Liu N; Kosari A; Li S; Akella Kamakshi D; Ayorinde O; Wentzloff DD; Calhoun BH
IEEE Trans Biomed Circuits Syst; 2019 Apr; 13(2):271-281. PubMed ID: 30676976
[TBL] [Abstract][Full Text] [Related]
28. Heart monitoring systems--a review.
Jain PK; Tiwari AK
Comput Biol Med; 2014 Nov; 54():1-13. PubMed ID: 25194717
[TBL] [Abstract][Full Text] [Related]
29. A 1.2V 1.5 microW 4 kS/s 10b Pipelined ADC for electroencephalogram applications.
Garcia-Gonzalez JM; Munoz F; Carvajal RG; Lopez-Morillo E; Elgmili H; Aguilar-Pelaez E
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5881-4. PubMed ID: 19164055
[TBL] [Abstract][Full Text] [Related]
30. An Analog Circuit Approximation of the Discrete Wavelet Transform for Ultra Low Power Signal Processing in Wearable Sensor Nodes.
Casson AJ
Sensors (Basel); 2015 Dec; 15(12):31914-29. PubMed ID: 26694414
[TBL] [Abstract][Full Text] [Related]
31. Wireless transmission of ECG signal.
Güler NF; Fidan U
J Med Syst; 2006 Jun; 30(3):231-5. PubMed ID: 16848136
[TBL] [Abstract][Full Text] [Related]
32. A 110-nW in-channel sigma-delta converter for large-scale neural recording implants.
Rezaei M; Maghsoudloo E; Sawan M; Gosselin B
Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():5741-5744. PubMed ID: 28269558
[TBL] [Abstract][Full Text] [Related]
33. A 36-nW Electrocardiogram Anomaly Detector Based on a 1.5-bit Non-Feedback Delta Quantizer for Always-on Cardiac Monitoring.
Pu N; Wu N; Abubakar SM; Yang Y; Liu X; Pan S; Guo Y; Jia W; Wang Z; Jiang H
IEEE Trans Biomed Circuits Syst; 2024 Jun; 18(3):648-661. PubMed ID: 38294924
[TBL] [Abstract][Full Text] [Related]
34. A low-voltage low-power front-end for wearable EEG systems.
Yates D; López-Morillo E; Carvajal RG; Ramirez-Angulo J; Rodriguez-Villegas E
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5282-5. PubMed ID: 18003199
[TBL] [Abstract][Full Text] [Related]
35. A computer based wireless system for online acquisition, monitoring and digital processing of ECG waveforms.
Bansal D; Khan M; Salhan AK
Comput Biol Med; 2009 Apr; 39(4):361-7. PubMed ID: 19261266
[TBL] [Abstract][Full Text] [Related]
36. Time-Interleaved SAR ADC with Background Timing-Skew Calibration for UWB Wireless Communication in IoT Systems.
Seong K; Jung DK; Yoon DH; Han JS; Kim JE; Kim TT; Lee W; Baek KH
Sensors (Basel); 2020 Apr; 20(8):. PubMed ID: 32344711
[TBL] [Abstract][Full Text] [Related]
37. Pseudo Asynchronous Level Crossing adc for ecg Signal Acquisition.
Marisa T; Niederhauser T; Haeberlin A; Wildhaber RA; Vogel R; Goette J; Jacomet M
IEEE Trans Biomed Circuits Syst; 2017 Apr; 11(2):267-278. PubMed ID: 28186908
[TBL] [Abstract][Full Text] [Related]
38. A 8.9-ENOB 2.5-εW 150-KS/s non-binary redundant successive approximation ADC in 0.18-microm CMOS for bio-implanted devices.
Chan KL; Lee AA; Yuan X; Krishna KR; Je M
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():650-3. PubMed ID: 21096546
[TBL] [Abstract][Full Text] [Related]
39. An ultra-low power (ULP) bandage-type ECG sensor for efficient cardiac disease management.
Shin K; Park GG; Kim JP; Lee TH; Ko BH; Kim YH
Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1474-7. PubMed ID: 24109977
[TBL] [Abstract][Full Text] [Related]
40. Constructing a multichannel electrocardiography system from a few standardized, high-level components.
Malkin RA
IEEE Eng Med Biol Mag; 1998; 17(1):34-8. PubMed ID: 9460618
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]