These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 28269487)

  • 1. Cortical responses following simultaneous and sequential retinal neurostimulation with different return configurations.
    Barriga-Rivera A; Morley JW; Lovell NH; Suaning GJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():5435-5438. PubMed ID: 28269487
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Visual cortex responses to single- and simultaneous multiple-electrode stimulation of the retina: implications for retinal prostheses.
    Shivdasani MN; Fallon JB; Luu CD; Cicione R; Allen PJ; Morley JW; Williams CE
    Invest Ophthalmol Vis Sci; 2012 Sep; 53(10):6291-300. PubMed ID: 22899754
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Visual cortex responses to suprachoroidal electrical stimulation of the retina: effects of electrode return configuration.
    Cicione R; Shivdasani MN; Fallon JB; Luu CD; Allen PJ; Rathbone GD; Shepherd RK; Williams CE
    J Neural Eng; 2012 Jun; 9(3):036009. PubMed ID: 22595310
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Spatial Restriction of Neural Activation Using Focused Multipolar Stimulation With a Retinal Prosthesis.
    Spencer TC; Fallon JB; Thien PC; Shivdasani MN
    Invest Ophthalmol Vis Sci; 2016 Jun; 57(7):3181-91. PubMed ID: 27309622
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Focal activation of the feline retina via a suprachoroidal electrode array.
    Wong YT; Chen SC; Seo JM; Morley JW; Lovell NH; Suaning GJ
    Vision Res; 2009 Mar; 49(8):825-33. PubMed ID: 19272402
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Virtual electrodes by current steering in retinal prostheses.
    Dumm G; Fallon JB; Williams CE; Shivdasani MN
    Invest Ophthalmol Vis Sci; 2014 Oct; 55(12):8077-85. PubMed ID: 25335975
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prediction of cortical responses to simultaneous electrical stimulation of the retina.
    Halupka KJ; Shivdasani MN; Cloherty SL; Grayden DB; Wong YT; Burkitt AN; Meffin H
    J Neural Eng; 2017 Feb; 14(1):016006. PubMed ID: 27900949
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cortical activation following chronic passive implantation of a wide-field suprachoroidal retinal prosthesis.
    Villalobos J; Fallon JB; Nayagam DA; Shivdasani MN; Luu CD; Allen PJ; Shepherd RK; Williams CE
    J Neural Eng; 2014 Aug; 11(4):046017. PubMed ID: 24965866
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spatiotemporal interactions in the visual cortex following paired electrical stimulation of the retina.
    Cicione R; Fallon JB; Rathbone GD; Williams CE; Shivdasani MN
    Invest Ophthalmol Vis Sci; 2014 Nov; 55(12):7726-38. PubMed ID: 25370517
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spatially restricted electrical activation of retinal ganglion cells in the rabbit retina by hexapolar electrode return configuration.
    Habib AG; Cameron MA; Suaning GJ; Lovell NH; Morley JW
    J Neural Eng; 2013 Jun; 10(3):036013. PubMed ID: 23612906
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quasi-monopolar electrical stimulation of the retina: a computational modelling study.
    Abramian M; Lovell NH; Habib A; Morley JW; Suaning GJ; Dokos S
    J Neural Eng; 2014 Apr; 11(2):025002. PubMed ID: 24556561
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Current steering in retinal stimulation via a quasimonopolar stimulation paradigm.
    Matteucci PB; Chen SC; Tsai D; Dodds CW; Dokos S; Morley JW; Lovell NH; Suaning GJ
    Invest Ophthalmol Vis Sci; 2013 Jun; 54(6):4307-20. PubMed ID: 23661370
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Suprachoroidal electrical stimulation: effects of stimulus pulse parameters on visual cortical responses.
    John SE; Shivdasani MN; Williams CE; Morley JW; Shepherd RK; Rathbone GD; Fallon JB
    J Neural Eng; 2013 Oct; 10(5):056011. PubMed ID: 23928717
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chronic electrical stimulation with a suprachoroidal retinal prosthesis: a preclinical safety and efficacy study.
    Nayagam DA; Williams RA; Allen PJ; Shivdasani MN; Luu CD; Salinas-LaRosa CM; Finch S; Ayton LN; Saunders AL; McPhedran M; McGowan C; Villalobos J; Fallon JB; Wise AK; Yeoh J; Xu J; Feng H; Millard R; McWade M; Thien PC; Williams CE; Shepherd RK
    PLoS One; 2014; 9(5):e97182. PubMed ID: 24853376
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimizing Stimulation Strategies for Retinal Electrical Stimulation: a Modelling Study.
    Alqahtani A; Al Abed A; Lovell NH; Dokos S
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():2872-2875. PubMed ID: 31946491
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of extraocular electrodes for a retinal prosthesis using evoked potentials in cat visual cortex.
    Chowdhury V; Morley JW; Coroneo MT
    J Clin Neurosci; 2005 Jun; 12(5):574-9. PubMed ID: 16051097
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Creating virtual electrodes with 2D current steering.
    Spencer TC; Fallon JB; Shivdasani MN
    J Neural Eng; 2018 Jun; 15(3):035002. PubMed ID: 29473543
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Effect of Electric Cross-Talk in Retinal Neurostimulation.
    Matteucci PB; Barriga-Rivera A; Eiber CD; Lovell NH; Morley JW; Suaning GJ
    Invest Ophthalmol Vis Sci; 2016 Mar; 57(3):1031-7. PubMed ID: 26962699
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis.
    Shivdasani MN; Luu CD; Cicione R; Fallon JB; Allen PJ; Leuenberger J; Suaning GJ; Lovell NH; Shepherd RK; Williams CE
    J Neural Eng; 2010 Jun; 7(3):036008. PubMed ID: 20479521
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vivo electrical stimulation of rabbit retina with a microfabricated array: strategies to maximize responses for prospective assessment of stimulus efficacy and biocompatibility.
    Rizzo JF; Goldbaum S; Shahin M; Denison TJ; Wyatt J
    Restor Neurol Neurosci; 2004; 22(6):429-43. PubMed ID: 15798362
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.