149 related articles for article (PubMed ID: 28269599)
1. Simultaneous reconstruction and segmentation with the Mumford-Shah functional for electron tomography.
Li Shen ; Quinto ET; Shiqiang Wang ; Ming Jiang
Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():5909-5912. PubMed ID: 28269599
[TBL] [Abstract][Full Text] [Related]
2. Compensation of missing wedge effects with sequential statistical reconstruction in electron tomography.
Paavolainen L; Acar E; Tuna U; Peltonen S; Moriya T; Soonsawad P; Marjomäki V; Cheng RH; Ruotsalainen U
PLoS One; 2014; 9(10):e108978. PubMed ID: 25279759
[TBL] [Abstract][Full Text] [Related]
3. Removing high contrast artifacts via digital inpainting in cryo-electron tomography: an application of compressed sensing.
Song K; Comolli LR; Horowitz M
J Struct Biol; 2012 May; 178(2):108-20. PubMed ID: 22248454
[TBL] [Abstract][Full Text] [Related]
4. ICON: 3D reconstruction with 'missing-information' restoration in biological electron tomography.
Deng Y; Chen Y; Zhang Y; Wang S; Zhang F; Sun F
J Struct Biol; 2016 Jul; 195(1):100-12. PubMed ID: 27079261
[TBL] [Abstract][Full Text] [Related]
5. FIRT: Filtered iterative reconstruction technique with information restoration.
Chen Y; Zhang Y; Zhang K; Deng Y; Wang S; Zhang F; Sun F
J Struct Biol; 2016 Jul; 195(1):49-61. PubMed ID: 27134004
[TBL] [Abstract][Full Text] [Related]
6. IPET and FETR: experimental approach for studying molecular structure dynamics by cryo-electron tomography of a single-molecule structure.
Zhang L; Ren G
PLoS One; 2012; 7(1):e30249. PubMed ID: 22291925
[TBL] [Abstract][Full Text] [Related]
7. LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure.
Zhai X; Lei D; Zhang M; Liu J; Wu H; Yu Y; Zhang L; Ren G
Sci Rep; 2020 Jun; 10(1):10489. PubMed ID: 32591588
[TBL] [Abstract][Full Text] [Related]
8. ℓ0 Gradient Minimization Based Image Reconstruction for Limited-Angle Computed Tomography.
Yu W; Zeng L
PLoS One; 2015; 10(7):e0130793. PubMed ID: 26158543
[TBL] [Abstract][Full Text] [Related]
9. Local regularization of tilt projections reduces artifacts in electron tomography.
Maiorca M; Millet C; Hanssen E; Abbey B; Kazmierczak E; Tilley L
J Struct Biol; 2014 Apr; 186(1):28-37. PubMed ID: 24632448
[TBL] [Abstract][Full Text] [Related]
10. A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis.
Zhang Y; Chan HP; Sahiner B; Wei J; Goodsitt MM; Hadjiiski LM; Ge J; Zhou C
Med Phys; 2006 Oct; 33(10):3781-95. PubMed ID: 17089843
[TBL] [Abstract][Full Text] [Related]
11. Progressive Stochastic Reconstruction Technique (PSRT) for cryo electron tomography.
Turoňová B; Marsalek L; Davidovič T; Slusallek P
J Struct Biol; 2015 Mar; 189(3):195-206. PubMed ID: 25659894
[TBL] [Abstract][Full Text] [Related]
12. Adaptive multiresolution method for MAP reconstruction in electron tomography.
Acar E; Peltonen S; Ruotsalainen U
Ultramicroscopy; 2016 Nov; 170():24-34. PubMed ID: 27522477
[TBL] [Abstract][Full Text] [Related]
13. Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization.
Dong X; Niu T; Zhu L
Med Phys; 2014 May; 41(5):051909. PubMed ID: 24784388
[TBL] [Abstract][Full Text] [Related]
14. Refinement procedure for the image alignment in high-resolution electron tomography.
Houben L; Bar Sadan M
Ultramicroscopy; 2011; 111(9-10):1512-20. PubMed ID: 21930024
[TBL] [Abstract][Full Text] [Related]
15. l0 regularization based on a prior image incorporated non-local means for limited-angle X-ray CT reconstruction.
Zhang L; Zeng L; Guo Y
J Xray Sci Technol; 2018; 26(3):481-498. PubMed ID: 29562578
[TBL] [Abstract][Full Text] [Related]
16. Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT.
Chen GH; Li Y
Med Phys; 2015 Aug; 42(8):4698-707. PubMed ID: 26233197
[TBL] [Abstract][Full Text] [Related]
17. Iterative image reconstruction using modified non-local means filtering for limited-angle computed tomography.
Qi H; Chen Z; Wu S; Xu Y; Zhou L
Phys Med; 2016 Sep; 32(9):1041-51. PubMed ID: 27501875
[TBL] [Abstract][Full Text] [Related]
18. Iterative reconstruction of cryo-electron tomograms using nonuniform fast Fourier transforms.
Chen Y; Förster F
J Struct Biol; 2014 Mar; 185(3):309-16. PubMed ID: 24326216
[TBL] [Abstract][Full Text] [Related]
19. It's noisy out there! A review of denoising techniques in cryo-electron tomography.
Frangakis AS
J Struct Biol; 2021 Dec; 213(4):107804. PubMed ID: 34732363
[TBL] [Abstract][Full Text] [Related]
20. A methodology for finding the optimal iteration number of the SIRT algorithm for quantitative Electron Tomography.
Okariz A; Guraya T; Iturrondobeitia M; Ibarretxe J
Ultramicroscopy; 2017 Feb; 173():36-46. PubMed ID: 27907830
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]