These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 28269686)

  • 1. Wireless EEG patch sensor on forehead using on-demand stretchable electrode sheet and electrode-tissue impedance scanner.
    Yoshimoto S; Araki T; Uemura T; Nezu T; Kondo M; Sasai K; Iwase M; Satake H; Yoshida A; Kikuchi M; Sekitani T
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():6286-6289. PubMed ID: 28269686
    [TBL] [Abstract][Full Text] [Related]  

  • 2. New disposable forehead electrode set with excellent signal quality and imaging compatibility.
    Myllymaa S; Lepola P; Töyräs J; Hukkanen T; Mervaala E; Lappalainen R; Myllymaa K
    J Neurosci Methods; 2013 Apr; 215(1):103-9. PubMed ID: 23411124
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Film Electrode upon Nanoarchitectonics of Bacterial Cellulose and Conductive Fabric for Forehead Electroencephalogram Measurement.
    Gao K; Wu N; Ji B; Liu J
    Sensors (Basel); 2023 Sep; 23(18):. PubMed ID: 37765945
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Novel hydrogel-based preparation-free EEG electrode.
    Alba NA; Sclabassi RJ; Sun M; Cui XT
    IEEE Trans Neural Syst Rehabil Eng; 2010 Aug; 18(4):415-23. PubMed ID: 20423811
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design, fabrication and experimental validation of a novel dry-contact sensor for measuring electroencephalography signals without skin preparation.
    Liao LD; Wang IJ; Chen SF; Chang JY; Lin CT
    Sensors (Basel); 2011; 11(6):5819-34. PubMed ID: 22163929
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel dry polymer foam electrodes for long-term EEG measurement.
    Lin CT; Liao LD; Liu YH; Wang IJ; Lin BS; Chang JY
    IEEE Trans Biomed Eng; 2011 May; 58(5):1200-7. PubMed ID: 21193371
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Towards emerging EEG applications: a novel printable flexible Ag/AgCl dry electrode array for robust recording of EEG signals at forehead sites.
    Li G; Wu J; Xia Y; Wu Y; Tian Y; Liu J; Chen D; He Q
    J Neural Eng; 2020 Mar; 17(2):026001. PubMed ID: 32000145
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Implanted electrodes for multi-month EEG.
    Jochum T; Engdahl S; Kolls BJ; Wolf P
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6543-8. PubMed ID: 25571495
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of the suitability of using a forehead EEG electrode set and chin EMG electrodes for sleep staging in polysomnography.
    Myllymaa S; Muraja-Murro A; Westeren-Punnonen S; Hukkanen T; Lappalainen R; Mervaala E; Töyräs J; Sipilä K; Myllymaa K
    J Sleep Res; 2016 Dec; 25(6):636-645. PubMed ID: 27230805
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrode scalp impedance differences between electroencephalography machines in healthy dogs.
    Luca J; Hazenfratz M; Monteith G; Sanchez A; Gaitero L; James F
    Can J Vet Res; 2021 Oct; 85(4):309-311. PubMed ID: 34602736
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Active electrode IC for EEG and electrical impedance tomography with continuous monitoring of contact impedance.
    Guermandi M; Cardu R; Franchi Scarselli E; Guerrieri R
    IEEE Trans Biomed Circuits Syst; 2015 Feb; 9(1):21-33. PubMed ID: 24860040
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of Low-Contact-Impedance Dry Electrodes for Electroencephalogram Signal Acquisition.
    Damalerio RB; Lim R; Gao Y; Zhang TT; Cheng MY
    Sensors (Basel); 2023 May; 23(9):. PubMed ID: 37177657
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Novel Bristle-Shaped Semi-Dry Electrode With Low Contact Impedance and Ease of Use Features for EEG Signal Measurements.
    Gao KP; Yang HJ; Liao LL; Jiang CP; Zhao N; Wang XL; Li XY; Chen X; Yang B; Liu J
    IEEE Trans Biomed Eng; 2020 Mar; 67(3):750-761. PubMed ID: 31170063
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Scalp electrode impedance, infection risk, and EEG data quality.
    Ferree TC; Luu P; Russell GS; Tucker DM
    Clin Neurophysiol; 2001 Mar; 112(3):536-44. PubMed ID: 11222977
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Advancing towards Ubiquitous EEG, Correlation of In-Ear EEG with Forehead EEG.
    Mandekar S; Holland A; Thielen M; Behbahani M; Melnykowycz M
    Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214468
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Dependence of Electrode Impedance on the Number of Performed EEG Examinations.
    Górecka J; Makiewicz P
    Sensors (Basel); 2019 Jun; 19(11):. PubMed ID: 31181738
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of electrode properties on EEG measurements and a related inverse problem.
    Ollikainen JO; Vauhkonen M; Karjalainen PA; Kaipio JP
    Med Eng Phys; 2000 Oct; 22(8):535-45. PubMed ID: 11182578
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wireless instrumentation system based on dry electrodes for acquiring EEG signals.
    Dias NS; Carmo JP; Mendes PM; Correia JH
    Med Eng Phys; 2012 Sep; 34(7):972-81. PubMed ID: 22153322
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Forehead EEG electrode set versus full-head scalp EEG in 100 patients with altered mental state.
    Muraja-Murro A; Mervaala E; Westeren-Punnonen S; Lepola P; Töyräs J; Myllymaa S; Julkunen P; Kantanen AM; Kälviäinen R; Myllymaa K
    Epilepsy Behav; 2015 Aug; 49():245-9. PubMed ID: 25997637
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electro-deposited Nanoporous Platinum Electrode for EEG Monitoring.
    Kim DY; Ku Y; Ahn JW; Kwon C; Kim HC
    J Korean Med Sci; 2018 May; 33(21):e154. PubMed ID: 29780294
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.