318 related articles for article (PubMed ID: 28273341)
21. The relative accuracy of 4D dose accumulation for lung radiotherapy using rigid dose projection versus dose recalculation on every breathing phase.
Valdes G; Lee C; Tenn S; Lee P; Robinson C; Iwamoto K; Low D; Lamb JM
Med Phys; 2017 Mar; 44(3):1120-1127. PubMed ID: 28019649
[TBL] [Abstract][Full Text] [Related]
22. Dosimetric evaluation in Helical TomoTherapy for lung SBRT using Monte Carlo-based independent dose verification software.
Kosaka T; Takatsu J; Inoue T; Iijima K; Suzuki M; Murakami N; Shikama N
J Appl Clin Med Phys; 2024 May; 25(5):e14305. PubMed ID: 38368607
[TBL] [Abstract][Full Text] [Related]
23. Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.
Liu H; Zhuang T; Stephans K; Videtic G; Raithel S; Djemil T; Xia P
J Appl Clin Med Phys; 2015 Nov; 16(6):91–99. PubMed ID: 26699560
[TBL] [Abstract][Full Text] [Related]
24. Monte Carlo dose calculation in presence of low-density media: Application to lung SBRT treated during DIBH.
Beilla S; Younes T; Vieillevigne L; Bardies M; Franceries X; Simon L
Phys Med; 2017 Sep; 41():46-52. PubMed ID: 28462867
[TBL] [Abstract][Full Text] [Related]
25. Does intensity modulation increase target dose calculation errors of conventional algorithms for lung SBRT?
Zheng D; Verma V; Wang S; Liang X; Zhou S
J Appl Clin Med Phys; 2018 Mar; 19(2):154-159. PubMed ID: 29388325
[TBL] [Abstract][Full Text] [Related]
26. Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size.
Huang B; Wu L; Lin P; Chen C
Radiat Oncol; 2015 Feb; 10():53. PubMed ID: 25886628
[TBL] [Abstract][Full Text] [Related]
27. Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases.
Hasenbalg F; Neuenschwander H; Mini R; Born EJ
Phys Med Biol; 2007 Jul; 52(13):3679-91. PubMed ID: 17664570
[TBL] [Abstract][Full Text] [Related]
28. Dosimetric comparison of pencil beam and Monte Carlo algorithms in conformal lung radiotherapy.
Elcim Y; Dirican B; Yavas O
J Appl Clin Med Phys; 2018 Sep; 19(5):616-624. PubMed ID: 30079474
[TBL] [Abstract][Full Text] [Related]
29. Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy.
Zhuang T; Djemil T; Qi P; Magnelli A; Stephans K; Videtic G; Xia P
J Appl Clin Med Phys; 2013 Mar; 14(2):4011. PubMed ID: 23470930
[TBL] [Abstract][Full Text] [Related]
30. Uncertainties in the dosimetric heterogeneity correction and its potential effect on local control in lung SBRT.
Erickson BG; Cui Y; Ackerson BG; Kelsey CR; Yin FF; Niedzwiecki D; Adamson J
Biomed Phys Eng Express; 2023 Mar; 9(3):. PubMed ID: 36827685
[No Abstract] [Full Text] [Related]
31. Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.
Seco J; Sharp GC; Wu Z; Gierga D; Buettner F; Paganetti H
Med Phys; 2008 Jan; 35(1):356-66. PubMed ID: 18293590
[TBL] [Abstract][Full Text] [Related]
32. A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation.
Zhao Y; Qi G; Yin G; Wang X; Wang P; Li J; Xiao M; Li J; Kang S; Liao X
Radiat Oncol; 2014 Dec; 9():287. PubMed ID: 25511623
[TBL] [Abstract][Full Text] [Related]
33. Stereotactic ablative radiation therapy for subcentimeter lung tumors: clinical, dosimetric, and image guidance considerations.
Louie AV; Senan S; Dahele M; Slotman BJ; Verbakel WF
Int J Radiat Oncol Biol Phys; 2014 Nov; 90(4):843-9. PubMed ID: 25585783
[TBL] [Abstract][Full Text] [Related]
34. The effect of density variation on photon dose calculation and its impact on intensity modulated radiotherapy and stereotactic body radiotherapy.
Liu Q; Liang J; Stanhope CW; Yan D
Med Phys; 2016 Oct; 43(10):5717. PubMed ID: 27782711
[TBL] [Abstract][Full Text] [Related]
35. The impact of photon dose calculation algorithms on expected dose distributions in lungs under different respiratory phases.
Fogliata A; Nicolini G; Vanetti E; Clivio A; Winkler P; Cozzi L
Phys Med Biol; 2008 May; 53(9):2375-90. PubMed ID: 18421117
[TBL] [Abstract][Full Text] [Related]
36. Monte Carlo evaluation of tissue inhomogeneity effects in the treatment of the head and neck.
Wang L; Yorke E; Chui CS
Int J Radiat Oncol Biol Phys; 2001 Aug; 50(5):1339-49. PubMed ID: 11483347
[TBL] [Abstract][Full Text] [Related]
37. Dosimetric errors during treatment of centrally located lung tumors with stereotactic body radiation therapy: Monte Carlo evaluation of tissue inhomogeneity corrections.
Altunbas C; Kavanagh B; Dzingle W; Stuhr K; Gaspar L; Miften M
Med Dosim; 2013; 38(4):436-41. PubMed ID: 24119416
[TBL] [Abstract][Full Text] [Related]
38. SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems.
Panettieri V; Wennberg B; Gagliardi G; Duch MA; Ginjaume M; Lax I
Phys Med Biol; 2007 Jul; 52(14):4265-81. PubMed ID: 17664607
[TBL] [Abstract][Full Text] [Related]
39. Adapted Prescription Dose for Monte Carlo Algorithm in Lung SBRT: Clinical Outcome on 205 Patients.
Bibault JE; Mirabel X; Lacornerie T; Tresch E; Reynaert N; Lartigau E
PLoS One; 2015; 10(7):e0133617. PubMed ID: 26207808
[TBL] [Abstract][Full Text] [Related]
40. Evaluation of the AAA Treatment Planning Algorithm for SBRT Lung Treatment: Comparison with Monte Carlo and Homogeneous Pencil Beam Dose Calculations.
Gete E; Teke T; Kwa W
J Med Imaging Radiat Sci; 2012 Mar; 43(1):26-33. PubMed ID: 31052016
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]