261 related articles for article (PubMed ID: 28273357)
1. Energy and field size dependence of a silicon diode designed for small-field dosimetry.
Yarahmadi M; Wegener S; Sauer OA
Med Phys; 2017 May; 44(5):1958-1964. PubMed ID: 28273357
[TBL] [Abstract][Full Text] [Related]
2. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
Moignier C; Huet C; Makovicka L
Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo modelling of diode detectors for small field MV photon dosimetry: detector model simplification and the sensitivity of correction factors to source parameterization.
Cranmer-Sargison G; Weston S; Evans JA; Sidhu NP; Thwaites DI
Phys Med Biol; 2012 Aug; 57(16):5141-53. PubMed ID: 22842678
[TBL] [Abstract][Full Text] [Related]
4. A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.
Casar B; Gershkevitsh E; Mendez I; Jurković S; Huq MS
Med Phys; 2019 Feb; 46(2):944-963. PubMed ID: 30521073
[TBL] [Abstract][Full Text] [Related]
5. Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.
Qin Y; Zhong H; Wen N; Snyder K; Huang Y; Chetty IJ
J Appl Clin Med Phys; 2016 Nov; 17(6):379-391. PubMed ID: 27929510
[TBL] [Abstract][Full Text] [Related]
6. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.
Benmakhlouf H; Sempau J; Andreo P
Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131
[TBL] [Abstract][Full Text] [Related]
7. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry.
Benmakhlouf H; Andreo P
Med Phys; 2017 Feb; 44(2):713-724. PubMed ID: 28032369
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.
Czarnecki D; Zink K
Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734
[TBL] [Abstract][Full Text] [Related]
9. Technical note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV-18 MeV.
Hermida-López M; Lüdemann L; Flühs A; Brualla L
Med Phys; 2014 Nov; 41(11):112103. PubMed ID: 25370654
[TBL] [Abstract][Full Text] [Related]
10. Energy response corrections for profile measurements using a combination of different detector types.
Wegener S; Sauer OA
Med Phys; 2018 Feb; 45(2):898-907. PubMed ID: 29193168
[TBL] [Abstract][Full Text] [Related]
11. Experimental determination of field factors ([Formula: see text]) for small radiotherapy beams using the daisy chain correction method.
Lárraga-Gutiérrez JM
Phys Med Biol; 2015 Aug; 60(15):5813-31. PubMed ID: 26161448
[TBL] [Abstract][Full Text] [Related]
12. Development of a silicon diode detector for skin dosimetry in radiotherapy.
Vicoroski N; Espinoza A; Duncan M; Oborn BM; Carolan M; Metcalfe P; Menichelli D; Perevertaylo VL; Lerch MLF; Rosenfeld AB; Petasecca M
Med Phys; 2017 Oct; 44(10):5402-5412. PubMed ID: 28696500
[TBL] [Abstract][Full Text] [Related]
13. Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors.
Cranmer-Sargison G; Weston S; Evans JA; Sidhu NP; Thwaites DI
Med Phys; 2011 Dec; 38(12):6592-602. PubMed ID: 22149841
[TBL] [Abstract][Full Text] [Related]
14. Spectral perturbations from silicon diode detector encapsulation and shielding in photon fields.
Eklund K; Ahnesjö A
Med Phys; 2010 Nov; 37(11):6055-60. PubMed ID: 21158317
[TBL] [Abstract][Full Text] [Related]
15. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
Kaveckyte V; Persson L; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
Med Phys; 2020 Mar; 47(3):1268-1279. PubMed ID: 31880809
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric characterization of Elekta stereotactic cones.
Borzov E; Nevelsky A; Bar-Deroma R; Orion I
J Appl Clin Med Phys; 2018 Jan; 19(1):194-203. PubMed ID: 29266744
[TBL] [Abstract][Full Text] [Related]
17. Technical Note: Angular dependence of a 2D monolithic silicon diode array for small field dosimetry.
Stansook N; Utitsarn K; Petasecca M; Newall MK; Duncan M; Nitschke K; Carolan M; Metcalfe P; Lerch MLF; Perevertaylo VL; Tomé WA; Rosenfeld AB
Med Phys; 2017 Aug; 44(8):4313-4321. PubMed ID: 28556261
[TBL] [Abstract][Full Text] [Related]
18. Low-energy photons in high-energy photon fields--Monte Carlo generated spectra and a new descriptive parameter.
Chofor N; Harder D; Willborn K; Rühmann A; Poppe B
Z Med Phys; 2011 Sep; 21(3):183-97. PubMed ID: 21530198
[TBL] [Abstract][Full Text] [Related]
19. Small-field measurement and Monte Carlo model validation of a novel image-guided radiotherapy system.
Shi M; Chuang CF; Kovalchuk N; Bush K; Zaks D; Xing L; Surucu M; Han B
Med Phys; 2021 Nov; 48(11):7450-7460. PubMed ID: 34628666
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo dosimetry study of a 6 MV stereotactic radiosurgery unit.
Verhaegen F; Das IJ; Palmans H
Phys Med Biol; 1998 Oct; 43(10):2755-68. PubMed ID: 9814515
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]