292 related articles for article (PubMed ID: 28291930)
1. Development and performance evaluation of a high-speed multileaf collimator.
Zhang X; Ye P; Zhang H
J Appl Clin Med Phys; 2017 Jan; 18(1):96-106. PubMed ID: 28291930
[TBL] [Abstract][Full Text] [Related]
2. Performance evaluation of a high-speed multileaf collimator in real-time IMRT delivery to moving targets.
Li F; Ye P; Zhang H
Med Phys; 2016 Mar; 43(3):1401-10. PubMed ID: 26936724
[TBL] [Abstract][Full Text] [Related]
3. Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator.
Hansen R; Ravkilde T; Worm ES; Toftegaard J; Grau C; Macek K; Poulsen PR
Med Phys; 2016 May; 43(5):2387. PubMed ID: 27147350
[TBL] [Abstract][Full Text] [Related]
4. 6 MV dosimetric characterization of the 160 MLC, the new Siemens multileaf collimator.
Tacke MB; Nill S; Häring P; Oelfke U
Med Phys; 2008 May; 35(5):1634-42. PubMed ID: 18561638
[TBL] [Abstract][Full Text] [Related]
5. Intensity modulated radiation therapy with irregular multileaf collimated field: a dosimetric study on the penumbra region with different leaf stepping patterns.
Chow JC; Grigorov GN; Jiang R
Med Phys; 2006 Dec; 33(12):4606-13. PubMed ID: 17278813
[TBL] [Abstract][Full Text] [Related]
6. A dosimetric characterization of a novel linear accelerator collimator.
Thompson CM; Weston SJ; Cosgrove VC; Thwaites DI
Med Phys; 2014 Mar; 41(3):031713. PubMed ID: 24593717
[TBL] [Abstract][Full Text] [Related]
7. Effects of collimator angle, couch angle, and starting phase on motion-tracking dynamic conformal arc therapy (4D DCAT).
Xu Z; Yao R; Podgorsak MB; Wang IZ
J Appl Clin Med Phys; 2017 Sep; 18(5):54-63. PubMed ID: 28730652
[TBL] [Abstract][Full Text] [Related]
8. Characterization of the Halcyon
Lim TY; Dragojević I; Hoffman D; Flores-Martinez E; Kim GY
J Appl Clin Med Phys; 2019 Apr; 20(4):106-114. PubMed ID: 30889312
[TBL] [Abstract][Full Text] [Related]
9. Monte Carlo implementation, validation, and characterization of a 120 leaf MLC.
Fix MK; Volken W; Frei D; Frauchiger D; Born EJ; Manser P
Med Phys; 2011 Oct; 38(10):5311-20. PubMed ID: 21992349
[TBL] [Abstract][Full Text] [Related]
10. Fast motion-including dose error reconstruction for VMAT with and without MLC tracking.
Ravkilde T; Keall PJ; Grau C; Høyer M; Poulsen PR
Phys Med Biol; 2014 Dec; 59(23):7279-96. PubMed ID: 25383729
[TBL] [Abstract][Full Text] [Related]
11. Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.
Sharma DS; Dongre PM; Mhatre V; Heigrujam M
J Appl Clin Med Phys; 2011 Apr; 12(3):3475. PubMed ID: 21844860
[TBL] [Abstract][Full Text] [Related]
12. Technical Note: In silico and experimental evaluation of two leaf-fitting algorithms for MLC tracking based on exposure error and plan complexity.
Caillet V; O'Brien R; Moore D; Poulsen P; Pommer T; Colvill E; Sawant A; Booth J; Keall P
Med Phys; 2019 Apr; 46(4):1814-1820. PubMed ID: 30719723
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo simulation based study of a proposed multileaf collimator for a telecobalt machine.
Sahani G; Dutt Sharma S; Dash Sharma PK; Sharma DN; Hussain SA
Med Phys; 2013 Feb; 40(2):021705. PubMed ID: 23387728
[TBL] [Abstract][Full Text] [Related]
14. Performance of a multi leaf collimator system for MR-guided radiation therapy.
Cai B; Li H; Yang D; Rodriguez V; Curcuru A; Wang Y; Wen J; Kashani R; Mutic S; Green O
Med Phys; 2017 Dec; 44(12):6504-6514. PubMed ID: 28887825
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.
Kehwar TS; Bhardwaj AK; Chakarvarti SK
J Appl Clin Med Phys; 2006 Aug; 7(3):43-54. PubMed ID: 17533348
[TBL] [Abstract][Full Text] [Related]
16. Spatial variation of dosimetric leaf gap and its impact on dose delivery.
Kumaraswamy LK; Schmitt JD; Bailey DW; Xu ZZ; Podgorsak MB
Med Phys; 2014 Nov; 41(11):111711. PubMed ID: 25370625
[TBL] [Abstract][Full Text] [Related]
17. A simple method for determining dosimetric leaf gap with cross-field dose width for rounded leaf-end multileaf collimator systems.
Lin CY; Shiau AC; Ji JH; Lee CJ; Wang TH; Hsu SH; Liang JA
Radiat Oncol; 2018 Nov; 13(1):222. PubMed ID: 30424789
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo modeling of a Novalis Tx Varian 6 MV with HD-120 multileaf collimator.
Vazquez-Quino LA; Massingill B; Shi C; Gutierrez A; Esquivel C; Eng T; Papanikolaou N; Stathakis S
J Appl Clin Med Phys; 2012 Sep; 13(5):3960. PubMed ID: 22955663
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of the Elekta Agility MLC performance using high-resolution log files.
Kabat CN; Defoor DL; Myers P; Kirby N; Rasmussen K; Saenz DL; Mavroidis P; Papanikolaou N; Stathakis S
Med Phys; 2019 Mar; 46(3):1397-1407. PubMed ID: 30702748
[TBL] [Abstract][Full Text] [Related]
20. Management of the interplay effect when using dynamic MLC sequences to treat moving targets.
Court LE; Wagar M; Ionascu D; Berbeco R; Chin L
Med Phys; 2008 May; 35(5):1926-31. PubMed ID: 18561668
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]