These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 28292707)

  • 1. Significance of in-situ dry-ice blasting on the microstructure, crystallinity and bonding strength of plasma-sprayed hydroxyapatite coatings.
    Dong S; Zeng J; Li L; Sun J; Yang X; Liao H
    J Mech Behav Biomed Mater; 2017 Jul; 71():136-147. PubMed ID: 28292707
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microstructure and mechanical properties of plasma sprayed HA/YSZ/Ti-6Al-4V composite coatings.
    Khor KA; Gu YW; Pan D; Cheang P
    Biomaterials; 2004 Aug; 25(18):4009-17. PubMed ID: 15046891
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fabrication and characterization of plasma-sprayed HA/SiO(2) coatings for biomedical application.
    Morks MF
    J Mech Behav Biomed Mater; 2008 Jan; 1(1):105-11. PubMed ID: 19627776
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of vapor-flame treatment on plasma sprayed hydroxyapatite coatings.
    Tao S; Heng J; Chuanxian D
    J Biomed Mater Res; 2000 Dec; 52(3):572-5. PubMed ID: 11007627
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Significance of melt-fraction in HVOF sprayed hydroxyapatite particles, splats and coatings.
    Khor KA; Li H; Cheang P
    Biomaterials; 2004; 25(7-8):1177-86. PubMed ID: 14643591
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Surface characteristics and dissolution behavior of plasma-sprayed hydroxyapatite coating.
    Sun L; Berndt CC; Khor KA; Cheang HN; Gross KA
    J Biomed Mater Res; 2002 Nov; 62(2):228-36. PubMed ID: 12209943
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Plasma-sprayed hydroxyapatite (HA) coatings with flame-spheroidized feedstock: microstructure and mechanical properties.
    Kweh SW; Khor KA; Cheang P
    Biomaterials; 2000 Jun; 21(12):1223-34. PubMed ID: 10811304
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization and stability of hydroxyapatite coatings prepared by an electrodeposition and alkaline-treatment process.
    Han Y; Fu T; Lu J; Xu K
    J Biomed Mater Res; 2001 Jan; 54(1):96-101. PubMed ID: 11077407
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vivo evaluation of plasma sprayed hydroxyapatite coatings having different crystallinity.
    Xue W; Tao S; Liu X; Zheng X; Ding C
    Biomaterials; 2004 Feb; 25(3):415-21. PubMed ID: 14585689
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of post coating heat treatment on microstructural, mechanical and electrochemical corrosion behaviour of vacuum plasma sprayed reinforced hydroxyapatite coatings.
    Singh A; Singh G; Chawla V
    J Mech Behav Biomed Mater; 2018 Sep; 85():20-36. PubMed ID: 29843093
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of hydroxyapatite containing a titania layer formed by anodization coupled with blasting.
    Kang MK; Moon SK; Kwon JS; Kim KM; Kim KN
    Acta Odontol Scand; 2014 Nov; 72(8):989-98. PubMed ID: 25005626
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bond strength determination of hydroxyapatite coatings on Ti-6Al-4V substrates using the LAser Shock Adhesion Test (LASAT).
    Guipont V; Jeandin M; Bansard S; Khor KA; Nivard M; Berthe L; Cuq-Lelandais JP; Boustie M
    J Biomed Mater Res A; 2010 Dec; 95(4):1096-104. PubMed ID: 20878900
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterization and mechanical behaviour of reinforced hydroxyapatite coatings deposited by vacuum plasma spray on SS-316L alloy.
    Singh A; Singh G; Chawla V
    J Mech Behav Biomed Mater; 2018 Mar; 79():273-282. PubMed ID: 29335194
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Implant surface modification using laser guided coatings: in vitro comparison of mechanical properties.
    Vasanthan A; Kim H; Drukteinis S; Lacefield W
    J Prosthodont; 2008 Jul; 17(5):357-64. PubMed ID: 18544138
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Plasma spraying of zirconia-reinforced hydroxyapatite composite coatings on titanium: part I: phase, microstructure and bonding strength.
    Chang E; Chang WJ; Wang BC; Yang CY
    J Mater Sci Mater Med; 1997 Apr; 8(4):193-200. PubMed ID: 15348759
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microstructures and bond strengths of plasma-sprayed hydroxyapatite coatings on porous titanium substrates.
    Oh IH; Nomura N; Chiba A; Murayama Y; Masahashi N; Lee BT; Hanada S
    J Mater Sci Mater Med; 2005 Jul; 16(7):635-40. PubMed ID: 15965595
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Suspension thermal spraying of hydroxyapatite: microstructure and in vitro behaviour.
    Bolelli G; Bellucci D; Cannillo V; Lusvarghi L; Sola A; Stiegler N; Müller P; Killinger A; Gadow R; Altomare L; De Nardo L
    Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():287-303. PubMed ID: 24268261
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterization of wet powder-sprayed zirconia/calcium phosphate coating for dental implants.
    Pardun K; Treccani L; Volkmann E; Li Destri G; Marletta G; Streckbein P; Heiss C; Rezwan K
    Clin Implant Dent Relat Res; 2015 Feb; 17(1):186-98. PubMed ID: 23574454
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of plasma-sprayed hydroxyapatite coatings and zirconia-reinforced hydroxyapatite composite coatings: in vivo study.
    Lee TM; Yang CY; Chang E; Tsai RS
    J Biomed Mater Res A; 2004 Dec; 71(4):652-60. PubMed ID: 15505828
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Phase stability and biological property evaluation of plasma sprayed hydroxyapatite coatings for orthopedic and dental applications.
    Vahabzadeh S; Roy M; Bandyopadhyay A; Bose S
    Acta Biomater; 2015 Apr; 17():47-55. PubMed ID: 25638672
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.